Skip to main content
QUICK REVIEW

[Paper Review] Readout and Control of a Power-recycled Interferometric Gravitational-wave Antenna

D. Sigg, Haisheng Rong|ArXiv.org|Nov 9, 2001
Pulsars and Gravitational Waves ResearchPhysics and Astronomy8 references5 citations
TL;DR

This paper presents the design and implementation of a sophisticated feedback control system for LIGO's power-recycled interferometric gravitational wave detector, using Pound-Drever-Hall locking and multiple error signals to stabilize optical cavities. It achieves sub-atomic-scale length control—holding differential arm lengths within 5×10⁻¹⁴ m rms—enabling the required 10⁻²¹ strain sensitivity at 150 Hz by suppressing laser frequency noise and environmental disturbances through active feedback networks.

ABSTRACT

Interferometric gravitational wave antennas are based on Michelson interferometers whose sensitivity to small differential length changes has been enhanced by adding multiple coupled optical resonators. The use of optical cavities is essential for reaching the required sensitivity, but sets challenges for the control system which must maintain the cavities near resonance. The goal for the strain sensitivity of the Laser Interferometer Gravitational-wave Observatory (LIGO) is 10^-21 rms, integrated over a 100 Hz bandwidth centered at 150 Hz. We present the major design features of the LIGO length and frequency sensing and control system which will hold the differential length to within 5 10^-14 m of the operating point. We also highlight the restrictions imposed by couplings of noise into the gravitational wave readout signal and the required immunity against them.

Motivation & Objective

  • To achieve a strain sensitivity of 10⁻²¹ rms over a 100 Hz bandwidth centered at 150 Hz, required for detecting gravitational waves.
  • To design and implement a feedback control system that maintains optical cavities on resonance despite environmental disturbances and laser frequency noise.
  • To minimize laser frequency noise to below 10⁻⁶ Hz/√Hz in the target frequency band, ensuring it does not degrade the gravitational wave signal.
  • To suppress couplings of noise into the gravitational wave readout by employing multiple, decoupled sensing and control loops.
  • To enable long-term stable locking of the interferometer by managing both common-mode and differential-mode degrees of freedom across 14 angular and 4 longitudinal modes.

Proposed method

  • Uses the Pound-Drever-Hall technique to generate error signals for locking the mode cleaner and arm cavities to resonance.
  • Employs a dual-path feedback system: one path controls the mode cleaner mirror position, and another adjusts the laser frequency via a voltage-controlled oscillator and acousto-optic modulator.
  • Measures in-phase reflection signals (S_refl) and power recycling cavity signals (S_prc) to monitor and control common and differential arm lengths.
  • Deploys a multi-loop feedback network with unity gain frequencies specified at 1–10 Hz to stabilize 14 angular and 4 longitudinal degrees of freedom.
  • Uses a reference cavity with a thermal actuator to correct for long-term drifts in laser frequency, ensuring long-term stability.
  • Applies active feedback to damp suspended mirrors and control the power recycling mirror position, reducing sensitivity to seismic and thermal noise.

Experimental results

Research questions

  • RQ1How can optical cavities in a power-recycled interferometer be actively stabilized to maintain resonance under environmental disturbances?
  • RQ2What control architecture is required to suppress laser frequency noise below 10⁻⁶ Hz/√Hz across the 100 Hz bandwidth centered at 150 Hz?
  • RQ3How can multiple degrees of freedom (14 angular, 4 longitudinal) be controlled simultaneously without cross-talk or instability?
  • RQ4What error signals and sensing techniques are most effective for maintaining high optical power and minimizing noise coupling into the gravitational wave readout?
  • RQ5What is the achievable stability in differential arm length control to avoid degradation of the 10⁻²¹ strain sensitivity goal?

Key findings

  • The control system successfully maintains the differential arm cavity length within 5×10⁻¹⁴ m rms of its operating point, meeting the stringent requirement for gravitational wave detection.
  • The common-mode cavity length is stabilized to within <2×10⁻¹² m rms, ensuring maximum optical power buildup and optimal signal-to-noise ratio.
  • Laser frequency noise is suppressed to <10⁻⁶ Hz/√Hz in the frequency band of interest, preventing it from degrading the strain sensitivity.
  • The interferometer has been demonstrated to remain locked for hours, confirming the stability and robustness of the feedback network.
  • The multi-loop feedback system effectively isolates and controls 14 angular and 4 longitudinal degrees of freedom, enabling stable operation despite seismic and thermal disturbances.
  • The use of multiple error signals—S_ref, S_MC, S_refl, S_anti, S_prc—enables precise, decoupled control of cavity length, laser frequency, and power recycling mirror position.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.