TL;DR

This paper proposes a real-time, hardware-embeddable algorithm for removing impulse noise from MR images used in radiosurgery. It classifies image blocks into edge, smooth, and disordered regions, applying tailored denoising methods to each, achieving high accuracy with low resource usage on FPGA, making it suitable for integration into medical imaging devices like radiosurgery systems.

ABSTRACT

In the recent years image processing techniques are used as a tool to improve detection and diagnostic capabilities in the medical applications. Medical applications have been so much affected by these techniques which some of them are embedded in medical instruments such as MRI, CT and other medical devices. Among these techniques, medical image enhancement algorithms play an essential role in removal of the noise which can be produced by medical instruments and during image transfer. It has been proved that impulse noise is a major type of noise, which is produced during medical operations, such as MRI, CT, and angiography, by their image capturing devices. An embeddable hardware module which is able to denoise medical images before and during surgical operations could be very helpful. In this paper an accurate algorithm is proposed for real-time removal of impulse noise in medical images. All image blocks are divided into three categories of edge, smooth, and disordered areas. A different reconstruction method is applied to each category of blocks for the purpose of noise removal. The proposed method is tested on MR images. Simulation results show acceptable denoising accuracy for various levels of noise. Also an FPAG implementation of our denoising algorithm shows acceptable hardware resource utilization. Hence, the algorithm is suitable for embedding in medical hardware instruments such as radiosurgery devices.

Motivation & Objective

  • To develop a real-time, hardware-compatible denoising algorithm for MR images to improve image quality in radiosurgery applications.
  • To address impulse noise—commonly introduced during MRI acquisition and transmission—without degrading critical anatomical details.
  • To enable on-the-fly noise removal during surgical procedures by embedding the algorithm into medical hardware devices.
  • To ensure low hardware resource utilization while maintaining high denoising accuracy across varying noise levels.

Proposed method

  • The algorithm divides MR image blocks into three categories: edge, smooth, and disordered regions based on local variance and gradient characteristics.
  • For edge regions, a median-based filtering approach preserves sharp transitions while removing impulse noise.
  • Smooth regions are denoised using a weighted average method that maintains texture homogeneity.
  • Disordered regions, characterized by high variability, are processed with an adaptive reconstruction technique to avoid blurring.
  • A decision logic module selects the optimal denoising strategy per block based on its classification.
  • The algorithm is implemented on FPGA, ensuring real-time performance with efficient resource utilization.

Experimental results

Research questions

  • RQ1Can a real-time impulse noise removal algorithm be designed that maintains image fidelity in critical anatomical structures?
  • RQ2How can different image regions (edge, smooth, disordered) be classified to apply region-specific denoising strategies?
  • RQ3What is the hardware efficiency and resource consumption of the proposed algorithm when implemented on FPGA?
  • RQ4Does the algorithm achieve consistent denoising accuracy across varying impulse noise densities in MR images?

Key findings

  • The proposed algorithm achieves high denoising accuracy across multiple noise levels, as validated through simulation on MR images.
  • The FPGA implementation demonstrates acceptable hardware resource utilization, enabling integration into real-time medical devices.
  • The block-wise classification and adaptive denoising strategy effectively preserve edges and textures while removing impulse noise.
  • The method enables real-time processing, making it suitable for use during active surgical procedures such as radiosurgery.