[Paper Review] Reconstructing effective ultrasound transducer models via distributed source inversion
The paper presents an adjoint-based distributed source inversion (DSI) framework to reconstruct a spatio-temporal, effective transducer source from measurements, validated on an aluminum half-cylinder and shown to improve RTM and FWI imaging.
Accurate modeling of ultrasound wave propagation is essential for high-fidelity simulation and imaging in ultrasonic testing. A primary challenge lies in characterizing the excitation source, particularly for transducers with large apertures relative to the acoustic wavelengths. In such cases, non-uniform excitation and spatial interference significantly affect the resulting radiation patterns. This paper proposes a distributed source inversion strategy to reconstruct an effective spatio-temporal transducer model that reproduces experimentally measured wavefields. The reconstructed source model captures aperture-dependent phase and amplitude variations without the need for detailed knowledge of the transducer structure. The approach is validated using directivity measurements on an aluminum half-cylinder, where simulations incorporating the reconstructed source model show close agreement with experimental directivity patterns and waveform shapes. Finally, synthetic studies on reverse time migration and full-waveform inversion demonstrate that accurate transducer modeling is critical for the success of simulation-based imaging and inversion workflows and significantly improves reconstruction quality.
Motivation & Objective
- Motivate the need for accurate source modeling in simulation-based ultrasound imaging (RTM/FWI) for NDT.
- Develop a flexible, data-driven method to recover a spatially distributed transducer source that captures aperture-dependent phase and amplitude variations.
- Validate the approach experimentally on an aluminum half-cylinder and assess robustness to source and receiver representations.
- Demonstrate the impact of calibrated source models on RTM and FWI performance in detecting defects.
Proposed method
- Model wave propagation with the 2D elastic wave equation and implement it via a spectral element method (SEM).
- Represent the effective source as a separable spatio-temporal expansion with Ns spatial and Nt temporal basis functions; implement as multiple point sources with directionality.
- Use adjoint-based optimization (L-BFGS with first-optimization-then-discretize gradient) to minimize misfit between simulated and observed data across receivers.
- Compute the gradient via the adjoint wavefield, with the gradient given by the time-discretized adjoint solution evaluated at source locations (∂χ/∂ˆfi,j ≈ −u†(xi,tj)∆t).
- Employ an optimal step length and two-stage inversion (steepest descent then L-BFGS) to recover the distributed source model.
- Investigate robustness to spatial source discretization and receiver sampling, and assess impact on RTM/FWI through synthetic experiments.
Experimental results
Research questions
- RQ1Can an adjoint-based distributed source inversion accurately reconstruct a spatio-temporal, effective transducer source from measured wavefields?
- RQ2How does the recovered source model compare to measured directivity and waveforms across aperture angles?
- RQ3What is the sensitivity of the inversion to the number of source points and receiver density?
- RQ4Does using a calibrated, heterogeneous source model improve RTM and FWI imaging of defects compared with point-source or uniform-source models?
Key findings
- The distributed source inversion successfully reproduces both waveform shapes and directivity across aperture angles on the aluminum half-cylinder dataset.
- A more balanced weighting across receivers (DSI 2) yields uniform convergence and better agreement at high aperture angles, though it may slow convergence.
- Increasing the number of source points beyond a modest count yields diminishing returns for reconstruction accuracy.
- Receiver sampling density critically affects accuracy; a 20° spacing suffices to interpolate the transducer’s directivity in the studied setup.
- Synthetic RTM/FWI experiments show that point-source and uniform-source models degrade imaging results, while the heterogeneous, DSI-derived source enables detection of closely spaced, back-wall defects and improves impedance reconstruction.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.