TL;DR

This paper evaluates the reconstruction accuracy of the Pierre Auger Observatory's surface detector array for extensive air showers, focusing on angular resolution and energy estimation via S(1000). Using event-by-event reconstruction and full Monte Carlo simulations, it demonstrates angular resolutions better than 2° for 3-station events and below 1° for higher multiplicities, with S(1000) energy estimation errors below 8% at high energies, dominated by shower development fluctuations.

ABSTRACT

The reconstruction of extensive air showers (arrival direction, core position and energy estimation) by the surface detector of the Pierre Auger Observatory is discussed together with the corresponding accuracy. We determine the angular reconstruction accuracy as a function of the station multiplicity by using two different aproaches. We discuss statistical and systematic uncertainties in the determination of the signal at 1000 m from the core, S(1000), which is used to estimate the primary energy.

Motivation & Objective

  • To determine the angular resolution of the surface detector array for extensive air shower events based on station multiplicity and shower geometry.
  • To quantify statistical and systematic uncertainties in the S(1000) energy estimator, a key observable for primary particle energy reconstruction.
  • To validate the error estimation framework using full Monte Carlo simulations and redundant station pair measurements.
  • To assess the impact of saturated stations and shower development fluctuations on S(1000) reconstruction accuracy.

Proposed method

  • Angular resolution is calculated event-by-event using the variance in arrival direction (θ and φ), with the space-angle resolution F(η) defined as F(η) = 1/2 (V[θ] + sin²(θ)V[φ]), and AR = 1.5√F(η).
  • A parabolic shower front model is used in the time-fitting procedure to reconstruct the shower geometry, minimizing time measurement uncertainty effects.
  • S(1000), the signal size at 1000 m from the shower core, is estimated using a modified NKG lateral distribution function with a variable slope β.
  • Systematic errors in S(1000) are evaluated by sampling β from a Gaussian distribution centered on a parameterized β(S(1000)), with σβ(S(1000)) = 0.71 × exp(−0.976 × log(S(1000))).
  • Statistical errors are derived from signal size uncertainties measured using adjacent station pairs.
  • Full Monte Carlo simulations using Corsika-generated showers are used to benchmark the total error in S(1000) by comparing reconstructed to true S(1000) values.

Experimental results

Research questions

  • RQ1What is the angular resolution of the surface detector array as a function of station multiplicity and zenith angle?
  • RQ2How do statistical and systematic uncertainties in S(1000) vary with signal size and station saturation?
  • RQ3To what extent do shower development fluctuations dominate the uncertainty in S(1000) at high energies?
  • RQ4How well does the empirical error estimation framework for S(1000) agree with full Monte Carlo simulations?
  • RQ5Does the use of redundant station pairs provide consistent validation of the angular resolution and S(1000) error estimates?

Key findings

  • The angular resolution is better than 2° for 3-station events (E < 4 EeV), improves to below 1.2° for 4- and 5-fold events (3 < E < 10 EeV), and reaches below 0.9° for 6 or more stations (E > 10 EeV).
  • The total error in S(1000) is below 8% at high energies for events with saturated stations and below 12% for those without, with statistical errors dominating for S(1000) < 40 VEM.
  • Systematic errors in S(1000) arise primarily from fluctuations in the lateral distribution function slope β, which are parameterized as σβ(S(1000)) = 0.71 × exp(−0.976 × log(S(1000))).
  • The error budget for S(1000) is systematically 5% higher in events with saturated stations due to signal nonlinearity.
  • Full Monte Carlo simulations confirm the total error estimation, showing excellent agreement with data-based error estimates, with a slight 4% overestimation for high-energy saturated events.
  • No significant dependence of S(1000) errors on zenith angle is observed, and a small bias in S(1000) reconstruction is found only for S(1000) < 10 VEM.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint