[Paper Review] Recurrent convolutional neural networks for mandible segmentation from computed tomography
This paper proposes RSegCNN, a recurrent convolutional neural network that integrates encoder-decoder segmentation networks with recurrent structures to improve mandible segmentation in head and neck CT scans. By leveraging spatial continuity across adjacent slices, the method achieves state-of-the-art performance, particularly in handling weak edges and metal artifacts, with a Dice score of 95.10% on the PDDCA dataset.
Recently, accurate mandible segmentation in CT scans based on deep learning methods has attracted much attention. However, there still exist two major challenges, namely, metal artifacts among mandibles and large variations in shape or size among individuals. To address these two challenges, we propose a recurrent segmentation convolutional neural network (RSegCNN) that embeds segmentation convolutional neural network (SegCNN) into the recurrent neural network (RNN) for robust and accurate segmentation of the mandible. Such a design of the system takes into account the similarity and continuity of the mandible shapes captured in adjacent image slices in CT scans. The RSegCNN infers the mandible information based on the recurrent structure with the embedded encoder-decoder segmentation (SegCNN) components. The recurrent structure guides the system to exploit relevant and important information from adjacent slices, while the SegCNN component focuses on the mandible shapes from a single CT slice. We conducted extensive experiments to evaluate the proposed RSegCNN on two head and neck CT datasets. The experimental results show that the RSegCNN is significantly better than the state-of-the-art models for accurate mandible segmentation.
Motivation & Objective
- Address the challenge of inaccurate mandible segmentation in CT scans due to metal artifacts and high anatomical variability.
- Improve segmentation robustness in regions with weak or blurry edges, such as the condyles and ramus.
- Reduce computational complexity in 3D segmentation without sacrificing image quality or performance.
- Enable end-to-end, automated mandible segmentation suitable for clinical 3D virtual surgical planning.
- Leverage temporal (anatomical) sequence continuity across slices to enhance structural consistency in segmentation.
Proposed method
- Integrate a 2D U-Net-style encoder-decoder segmentation network (SegCNN) into a recurrent neural network (RNN) architecture to model sequential dependencies across CT slices.
- Use the RNN to propagate shape and context information from previous slices as a prior for segmenting the current slice, enhancing structural continuity.
- Apply a hybrid loss function combining Dice loss and binary cross-entropy (BCE) to optimize segmentation accuracy and boundary precision.
- Process 2D slices sequentially through the RNN, maintaining hidden states that encode contextual information from prior slices.
- Utilize the recurrent structure to stabilize predictions in low-contrast or artifact-affected regions, such as dental areas.
- Train the model end-to-end on 109 H&N CT scans from a private dataset and 40 scans from the PDDCA public dataset.
Experimental results
Research questions
- RQ1Can recurrent modeling of sequential CT slices improve segmentation accuracy for the mandible compared to standard 2D or 3D CNNs?
- RQ2To what extent does the RNN-based architecture enhance segmentation in regions with weak or blurred edges, such as the condyles and ramus?
- RQ3Does incorporating shape continuity across slices reduce sensitivity to metal artifacts and noise in dental regions?
- RQ4Can the proposed method maintain high performance while reducing computational complexity compared to 3D volumetric networks?
- RQ5How does the RSegCNN compare to state-of-the-art methods in terms of Dice score, average surface distance (ASD), and 95% Hausdorff distance (95HD) on benchmark datasets?
Key findings
- The RSegCNN achieved a Dice score of 95.10% (±1.21) on the PDDCA dataset, outperforming all state-of-the-art methods listed in Table 3.
- The method achieved an average surface distance (ASD) of 0.1367 mm (±0.0382), significantly lower than most baselines, indicating high boundary accuracy.
- The 95% Hausdorff distance (95HD) was 1.356 mm (±0.4487), demonstrating robustness in capturing the most extreme segmentation errors.
- Visual inspection confirmed superior performance in segmenting challenging regions like the condyles and ramus, which are critical for 3D surgical planning.
- The ablation study showed that removing the RNN module led to a noticeable drop in performance, confirming the value of recurrent modeling.
- The method demonstrated strong generalization to low-contrast and artifact-affected areas, indicating resilience to common clinical imaging challenges.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.