[Paper Review] RELAY: Robotic EyeLink AnalYsis of the EyeLink 1000 using an Artificial Eye
This study uses a robotic artificial eye with fixed pupil size to isolate the effects of brightness and gaze direction on EyeLink 1000 eye tracker performance. It confirms high accuracy and precision in peak velocity and pupil size measurement, finding no brightness-induced artifacts, but detects small, systematic pupil size variations due to gaze direction—primarily from geometric projection effects, not illumination or pupil dynamics.
There is a widespread assumption that the peak velocities of visually guided saccades in the dark are up to 10~\% slower than those made in the light. Studies that questioned the impact of the surrounding brightness conditions, come to differing conclusions, whether they have an influence or not and if so, in which manner. The problem is of a complex nature as the illumination condition itself may not contribute to different measured peak velocities solely but in combination with the estimation of the pupil size due to its deformation during saccades or different gaze positions. Even the measurement technique of video-based eye tracking itself could play a significant role. To investigate this issue, we constructed a stepper motor driven artificial eye with fixed pupil size to mimic human saccades with predetermined peak velocity \& amplitudes under three different brightness conditions with the EyeLink 1000, one of the most common used eye trackers. The aim was to control the pupil and brightness. With our device, an overall good accuracy and precision of the EyeLink 1000 could be confirmed. Furthermore, we could find that there is no artifact for pupil based eye tracking in relation to changing brightness conditions, neither for the pupil size nor for the peak velocities. What we found, was a systematic, small, yet significant change of the measured pupil sizes as a function of different gaze directions.
Motivation & Objective
- To investigate whether ambient brightness conditions affect the measurement of saccadic peak velocities and pupil size in video-based eye tracking.
- To isolate the influence of brightness from other confounding factors such as pupil deformation, gaze direction, and eye tracker signal processing.
- To evaluate the accuracy and precision of the EyeLink 1000 under controlled conditions using a mechanically driven artificial eye with fixed pupil size.
- To determine whether observed variations in peak velocity or pupil size are due to the eye tracker's response to lighting or geometric projection effects.
- To provide a benchmark for future human studies by quantifying baseline measurement variability independent of biological eye dynamics.
Proposed method
- A stepper motor-driven artificial eye was constructed with a fixed 5 mm pupil diameter to simulate saccadic eye movements with predefined amplitudes and peak velocities.
- The EyeLink 1000 was used to record gaze and pupil data under three distinct brightness conditions (high, medium, low) while maintaining constant pupil size.
- Gaze positions were systematically varied across horizontal (left, right, center) and vertical (up, down, center) directions to assess geometric projection effects on pupil size estimation.
- Pupil size and peak velocity were measured in centroid mode using the EyeLink 1000’s standard algorithm, with data analyzed for deviations across conditions.
- Statistical analysis compared measured pupil sizes and peak velocities across gaze directions and brightness levels to detect systematic biases.
- MATLAB code and data processing pipelines were developed and shared in a public repository for reproducibility and further benchmarking.
Experimental results
Research questions
- RQ1Does ambient brightness condition systematically affect the measured peak velocity of saccades in the EyeLink 1000?
- RQ2Does the EyeLink 1000 produce measurement artifacts in pupil size estimation under varying illumination levels when pupil size is fixed?
- RQ3Are there systematic deviations in pupil size estimation due to gaze direction, independent of illumination or pupil dynamics?
- RQ4To what extent do geometric projection effects from the camera’s position relative to the artificial eye influence apparent pupil size?
- RQ5Can the observed non-linear pattern in peak velocity across brightness conditions in prior human studies be explained by measurement artifacts or biological factors?
Key findings
- The EyeLink 1000 demonstrated high accuracy and precision in measuring saccadic peak velocities and pupil size across all tested brightness conditions.
- No systematic artifacts were found in peak velocity or pupil size measurements due to changes in ambient brightness when pupil size was fixed.
- Small but statistically significant variations in measured pupil size were observed as a function of gaze direction, ranging from -2.565% (right) to +3.131% (left) horizontally, and -0.375% (middle) to +0.675% (down) vertically.
- These variations were attributed to geometric projection effects—specifically, changes in pupil shape (from circular to elliptical) due to oblique viewing angles from the camera’s fixed position.
- The observed deviations were smaller than those reported in prior studies using artificial eyes, suggesting that the current setup minimized confounding factors.
- The results imply that the non-linear 'roof-shaped' pattern in peak velocity across brightness levels reported in human studies is unlikely to be due to eye tracker artifacts and may instead reflect underlying neurophysiological factors.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.