TL;DR

This paper proposes a robust, joint alignment method for multiple versions of a musical piece by leveraging multiple comparisons simultaneously, improving alignment accuracy and robustness over pairwise methods. By using multiscale DTW with chroma and onset features on a progressive alignment framework, the method reduces average alignment error by 14% and standard deviation by 53% compared to state-of-the-art pairwise approaches on Mazurka Project recordings.

ABSTRACT

Large music content libraries often comprise multiple versions of a piece of music. To establish a link between different versions, automatic music alignment methods map each position in one version to a corresponding position in another version. Due to the leeway in interpreting a piece, any two versions can differ significantly, for example, in terms of local tempo, articulation, or playing style. For a given pair of versions, these differences can be significant such that even state-of-the-art methods fail to identify a correct alignment. In this paper, we present a novel method that increases the robustness for difficult to align cases. Instead of aligning only pairs of versions as done in previous methods, our method aligns multiple versions in a joint manner. This way, the alignment can be computed by comparing each version not only with one but with several versions, which stabilizes the comparison and leads to an increase in alignment robustness. Using recordings from the Mazurka Project, the alignment error for our proposed method was 14% lower on average compared to a state-of-the-art method, with significantly less outliers (standard deviation 53% lower).

Motivation & Objective

  • To address the challenge of aligning musically diverse recordings with significant tempo, articulation, and dynamic differences that degrade pairwise alignment performance.
  • To improve alignment robustness in difficult cases where pairwise methods fail due to expressive interpretation variations.
  • To develop a scalable, joint alignment framework that exploits redundancy and consistency across multiple versions of the same musical piece.
  • To enhance synchronization accuracy in music information retrieval tasks such as score following, cover song detection, and content linking.

Proposed method

  • Adapts multiple sequence alignment (MSA) from bioinformatics to music alignment, enabling joint comparison of multiple audio versions simultaneously.
  • Uses a progressive alignment strategy that sequentially aligns each recording to a growing template, starting with the longest recording.
  • Employs Multiscale-DTW (FastDTW) for efficient dynamic time warping with reduced computational cost.
  • Integrates chroma features for pitch content and DLNCO (chroma-based onset indicators) to enhance onset detection and temporal precision.
  • Applies a cost matrix with gap penalties and step size constraints to ensure monotonic, boundary-valid alignments.
  • Uses length-based ordering for alignment sequence to improve stability, despite no significant performance difference from DTW-cost-based ordering.

Experimental results

Research questions

  • RQ1Can joint alignment of multiple music versions improve robustness compared to pairwise alignment in the presence of expressive performance variations?
  • RQ2How does the order of alignment (e.g., by length or DTW cost) affect the final alignment accuracy and stability?
  • RQ3To what extent do onset-indicator features (DLNCO) contribute to alignment accuracy in a joint alignment framework?
  • RQ4Does iterative realignment of versions after initial template creation improve alignment quality?
  • RQ5How does the use of multiple reference versions stabilize alignment when pairwise comparisons fail?

Key findings

  • The proposed joint alignment method reduced average alignment error by 14% compared to a state-of-the-art pairwise method on the Mazurka Project dataset.
  • The standard deviation of alignment error was reduced by 53%, indicating significantly fewer outliers and greater robustness.
  • Using chroma-based onset indicators (DLNCO) improved alignment accuracy, as disabling them increased mean alignment error from 59ms to 80ms for one example.
  • The length-based alignment ordering strategy outperformed or matched the DTW-cost-based strategy, suggesting a potential link between tempo and expressive parameter variation.
  • Iterative realignment did not improve results and even worsened alignment for some recordings, indicating no benefit from reprocessing after initial alignment.
  • The method demonstrated consistent improvements across multiple Mazurka recordings, especially in challenging cases with high interpretive variation.