[Paper Review] Rooftop PV detections from aerial imagery over France
This paper proposes an unsupervised, open-source method to assess the downstream accuracy of deep learning-based solar panel mapping pipelines over large-scale deployment areas using publicly available data. It introduces Downstream Task Accuracy (DTA), showing that test-set performance overestimates real-world accuracy by ~30 percentage points in installed capacity estimation, enabling safer industrial deployment of PV mapping systems in France and beyond.
Dataset containing the rooftop PV detections from IGN aerial imagery. File format : .geojson For each detection, The geometry corresponds to its minimum bounding rectangle, The properties are the following : `surface` the polygon surface in squared meters, `yield_kwh` : the raw annual production (in kWh), estimated from PVGis `kwp_approx` : the installed capacity (in kWp), `year` : the detection year (i.e., the year of the corresponding IGN imagery) The dataset contains a total of 459 034 detections for an aggregated installed capacity of 2.296 GWp.
Motivation & Objective
- To address the lack of systematic, unsupervised accuracy assessment for deep learning-based distributed PV mapping pipelines in real-world deployment areas.
- To quantify the performance gap between test-set accuracy and real-world accuracy in estimating installed capacity of distributed PV systems.
- To enable transmission system operators (TSOs) to trust and deploy automated PV mapping systems with measurable, interpretable accuracy metrics.
- To provide a scalable, open-source framework for DTA that leverages publicly available data, such as the French National Registry of Installations (RNI), for validation.
Proposed method
- Define Downstream Task Accuracy (DTA) as the accuracy of a model’s predictions over the entire deployment area, expressed in terms of installed capacity estimation.
- Use high-resolution aerial imagery and a pre-trained deep learning model (e.g., YOLO or similar) to detect and estimate PV installations across ~50,000 km² in France.
- Leverage the French National Registry of Installations (RNI) as a ground truth reference for validation, enabling unsupervised comparison without manual labeling.
- Compute DTA using metrics such as Mean Absolute Percentage Error (MAPE), mean Absolute Percentage Error (APE), and Absolute Installation Performance Error (AIPE) to assess estimation accuracy.
- Apply topological filtering (e.g., filtering detections by building presence) to evaluate its impact on DTA, improving accuracy in low-performing regions.
- Use publicly available orthoimagery and GIS data, ensuring replicability across European countries with similar data infrastructures (e.g., MaStR in Germany, Stamdata in Denmark).
Experimental results
Research questions
- RQ1How does the accuracy of deep learning-based PV mapping models in test sets compare to their actual performance in real-world deployment areas?
- RQ2Can an unsupervised, open-source method reliably estimate the accuracy of PV mapping models over large-scale deployment areas without human-annotated ground truth?
- RQ3To what extent does domain shift between training data and deployment areas degrade model performance in installed capacity estimation?
- RQ4How do post-processing filters (e.g., building-based filtering) affect the accuracy of PV mapping pipelines in low-performing regions?
- RQ5Can the proposed Downstream Task Accuracy (DTA) metric be generalized across different European countries with similar open data infrastructures?
Key findings
- The test-set accuracy of PV mapping models overestimates the actual accuracy in the deployment area by approximately 30 percentage points in installed capacity estimation.
- The Downstream Task Accuracy (DTA) metric, computed using the RNI as ground truth, reveals a mean MAPE of 47.45% across all French départements, indicating substantial estimation error in real-world deployment.
- Filtering detections by building presence improves accuracy significantly in low-performing départements such as Nord and Hérault, reducing error metrics by a large margin.
- The model’s performance is relatively consistent across most départements, but the Nord and Hérault show the highest error, with MAPE values exceeding 50% without filtering.
- The overall DTA shows a mean AIPE of 16.33% and a mean ratio of estimated to actual capacity slightly above 1, indicating a slight overestimation of total installed capacity.
- The method is scalable and replicable across Europe, as high-resolution orthoimagery and national PV registries (e.g., MaStR, Stamdata) are increasingly available under open data policies.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.