TL;DR

This paper presents ROSETLineBot, a low-cost, one-wheel-drive mobile robot designed for continuous inspection of high-voltage power transmission lines. Utilizing a modular design and active balancing control, the robot maintains stability on overhead conductors and enables real-time data collection via integrated sensors, significantly reducing inspection risks and operational costs compared to manual methods.

ABSTRACT

Continuous operation of the electrical transmission lines is of great importance for today's electricity-dependent world. It is crucial to detect and diagnose a possible problem on the lines before that occurs. In general, maintenance, repair and error detection operations of the electrical transmission lines are performed by humans periodically. However, these difficult tasks contain high-risks in terms of occupational health and safety. Moreover, it is not possible to continuously inspect these lines which extend over long distances by maintenance and repair personnel. For all these reasons, it is very convenient to use robotic systems for inspection on power transmission lines. By evaluating the data which are provided from sensors and cameras of robotic systems, it would be possible to take precautions before an error occurs. Robotic systems that can move continuously along the line would be able to gather continuous and uninterrupted information. Thus, potential problems can be detected and identified in advance. In this study, a single wheel drive low-cost mobile robot is designed and controlled which can work and move on the electrical transmission lines. Because of the modular structure of the designed robot, different types of sensors can be integrated into the robot, easily. The designed low-cost robotic system will cause minimum losses in case of possible breakage.

Motivation & Objective

  • To address the high-risk, labor-intensive nature of manual power line inspections in overhead transmission systems.
  • To develop a cost-effective robotic solution capable of continuous, autonomous movement along energized power lines.
  • To enable real-time monitoring and early fault detection through integrated sensors and stable locomotion.
  • To ensure robustness and modularity for easy sensor integration and minimal repair costs.
  • To demonstrate feasibility of a single-wheel-drive mechanism for stable, dynamic balancing on overhead conductors.

Proposed method

  • Design of a one-wheel-drive mobile robot with a centralized balancing mechanism using a rotary inertial actuator.
  • Implementation of a feedback control system based on a linear quadratic regulator (LQR) to maintain balance on the power line.
  • Use of a modular mechanical structure allowing easy integration of various sensors (e.g., cameras, environmental sensors).
  • Employment of a DC motor-driven wheel for propulsion, enabling forward and backward motion along the conductor.
  • Design of a lightweight, rigid frame with a center of mass aligned to the wheel axis for improved stability.
  • Integration of a real-time control system using embedded microcontrollers for dynamic adjustment of balance and motion.

Experimental results

Research questions

  • RQ1Can a single-wheel-drive robot achieve stable, continuous locomotion on overhead power transmission lines?
  • RQ2How effective is the active balancing control system in maintaining stability under dynamic disturbances?
  • RQ3To what extent can the modular design support integration of diverse inspection sensors?
  • RQ4What is the cost-effectiveness and robustness of the proposed design compared to conventional inspection methods?
  • RQ5Can the robot operate reliably on long-distance transmission lines with minimal maintenance?

Key findings

  • The robot successfully demonstrated stable, continuous motion along a simulated power line using active balancing control.
  • The LQR-based control system effectively maintained balance despite minor disturbances and line variations.
  • The modular design enabled seamless integration of multiple sensors, including visual and environmental monitoring systems.
  • The robot achieved low-cost operation with minimal component failure risk due to its simple mechanical structure.
  • The system showed potential for long-duration inspections, reducing reliance on manual labor and improving safety.
  • The one-wheel-drive mechanism proved feasible for dynamic, stable movement on overhead conductors.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint