[Paper Review] Rotate to Scan: UNet-like Mamba with Triplet SSM Module for Medical Image Segmentation
This paper proposes TM-UNet, a lightweight U-Net-like architecture for medical image segmentation that integrates a novel Triplet SSM module and residual VSS blocks to enhance feature fusion across spatial and channel dimensions. By leveraging selective scan operations with multi-directional feature transpositions, the model achieves state-of-the-art performance with 30% fewer parameters than VM-UNet, reducing parameters to 14.86M while improving mIoU and DSC across multiple benchmark datasets.
Image segmentation holds a vital position in the realms of diagnosis and treatment within the medical domain. Traditional convolutional neural networks (CNNs) and Transformer models have made significant advancements in this realm, but they still encounter challenges because of limited receptive field or high computing complexity. Recently, State Space Models (SSMs), particularly Mamba and its variants, have demonstrated notable performance in the field of vision. However, their feature extraction methods may not be sufficiently effective and retain some redundant structures, leaving room for parameter reduction. Motivated by previous spatial and channel attention methods, we propose Triplet Mamba-UNet. The method leverages residual VSS Blocks to extract intensive contextual features, while Triplet SSM is employed to fuse features across spatial and channel dimensions. We conducted experiments on ISIC17, ISIC18, CVC-300, CVC-ClinicDB, Kvasir-SEG, CVC-ColonDB, and Kvasir-Instrument datasets, demonstrating the superior segmentation performance of our proposed TM-UNet. Additionally, compared to the previous VM-UNet, our model achieves a one-third reduction in parameters.
Motivation & Objective
- To address the limitations of CNNs and Transformers in medical image segmentation, particularly limited receptive fields and high computational complexity.
- To improve feature representation in Mamba-based models by enabling effective cross-dimensional (spatial and channel) feature fusion.
- To reduce model parameters and FLOPs while maintaining or improving segmentation accuracy for real-time clinical deployment.
- To design a parameter-efficient, attention-like mechanism using State Space Models that avoids the high parameter cost of self-attention.
- To develop a lightweight, efficient, and accurate U-Net variant based on Mamba for medical image segmentation.
Proposed method
- Proposes a Triplet SSM module that applies selective scan operations after multiple transpositions of feature maps to capture spatial and channel-wise dependencies.
- Integrates residual VSS blocks as the backbone of the encoder and decoder for efficient feature extraction.
- Uses feature transposition to reconfigure spatial and channel dimensions, enabling the SSM to learn cross-dimensional interactions through selective scanning.
- Employs a bottleneck design with Triplet SSM to fuse spatial and channel features, replacing standard attention or convolutional layers.
- Adopts a U-Net-like architecture with skip connections to preserve fine-grained details and enhance feature flow.
- Utilizes pre-trained VMamba-S weights for initialization to improve convergence and performance.
Experimental results
Research questions
- RQ1Can a Mamba-based U-Net architecture achieve superior segmentation performance with significantly reduced parameters compared to existing SSM-based models?
- RQ2Does the proposed Triplet SSM module effectively capture cross-dimensional (spatial and channel) feature interactions without relying on attention mechanisms?
- RQ3How does the integration of residual VSS blocks and Triplet SSM impact model accuracy and parameter efficiency?
- RQ4To what extent does the proposed TM-UNet outperform state-of-the-art models like VM-UNet and VM-UNetV2 on diverse medical image segmentation benchmarks?
- RQ5Can the model maintain high performance while reducing FLOPs and inference time for real-time surgical applications?
Key findings
- TM-UNet reduces parameters to 14.86M, achieving a 30% reduction compared to VM-UNet (22.08M), with lower FLOPs (3.42G vs. 4.73G).
- On ISIC17, TM-UNet achieves mIoU of 80.51%, DSC of 89.20%, and Acc of 96.46%, outperforming VM-UNet and VM-UNetV2.
- On ISIC18, TM-UNet achieves mIoU of 81.55%, DSC of 89.84%, and Acc of 95.08%, showing consistent improvement across metrics.
- On CVC-ColonDB, TM-UNet improves mIoU by 6.54% and DSC by 5.49% compared to VM-UNet, demonstrating strong generalization on polyp segmentation.
- Ablation studies confirm that the Triplet SSM and residual connections contribute significantly to performance with minimal parameter increase.
- The model maintains high sensitivity (87.37% on ISIC17) and specificity (98.28% on ISIC17), indicating robustness in detecting lesions.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.