Skip to main content
QUICK REVIEW

[Paper Review] SAR-U-Net: squeeze-and-excitation block and atrous spatial pyramid pooling based residual U-Net for automatic liver CT segmentation.

Jinke Wang, Peiqing Lv|arXiv (Cornell University)|Mar 11, 2021
Radiomics and Machine Learning in Medical ImagingMedicine3 citations
TL;DR

This paper proposes SAR-U-Net, a 2D U-Net variant enhanced with squeeze-and-excitation (SE) blocks for attention-based feature recalibration, atrous spatial pyramid pooling (ASPP) for multi-scale context aggregation, and residual learning to enable deep training. The model achieves state-of-the-art performance on LiTS17 and SLiver07 datasets, with Dice scores of 95.71% and 97.31%, respectively, demonstrating superior accuracy and robustness in challenging liver CT segmentation scenarios.

ABSTRACT

Background and objective: In this paper, a modified U-Net based framework is presented, which leverages techniques from Squeeze-and-Excitation (SE) block, Atrous Spatial Pyramid Pooling (ASPP) and residual learning for accurate and robust liver CT segmentation, and the effectiveness of the proposed method was tested on two public datasets LiTS17 and SLiver07. Methods: A new network architecture called SAR-U-Net was designed. Firstly, the SE block is introduced to adaptively extract image features after each convolution in the U-Net encoder, while suppressing irrelevant regions, and highlighting features of specific segmentation task; Secondly, ASPP was employed to replace the transition layer and the output layer, and acquire multi-scale image information via different receptive fields. Thirdly, to alleviate the degradation problem, the traditional convolution block was replaced with the residual block and thus prompt the network to gain accuracy from considerably increased depth. Results: In the LiTS17 experiment, the mean values of Dice, VOE, RVD, ASD and MSD were 95.71, 9.52, -0.84, 1.54 and 29.14, respectively. Compared with other closely related 2D-based models, the proposed method achieved the highest accuracy. In the experiment of the SLiver07, the mean values of Dice, VOE, RVD, ASD and MSD were 97.31, 5.37, -1.08, 1.85 and 27.45, respectively. Compared with other closely related models, the proposed method achieved the highest segmentation accuracy except for the RVD. Conclusion: The proposed model enables a great improvement on the accuracy compared to 2D-based models, and its robustness in circumvent challenging problems, such as small liver regions, discontinuous liver regions, and fuzzy liver boundaries, is also well demonstrated and validated.

Motivation & Objective

  • To improve the accuracy and robustness of automatic liver segmentation in CT scans, particularly in the presence of small, discontinuous, or poorly defined liver regions.
  • To address the limitations of standard U-Net in capturing multi-scale contextual features and suppressing irrelevant features during segmentation.
  • To enhance deep network training by mitigating the degradation problem common in very deep architectures.
  • To validate the effectiveness of the proposed architecture on public benchmark datasets, LiTS17 and SLiver07.

Proposed method

  • Integrates squeeze-and-excitation (SE) blocks after each convolutional layer in the U-Net encoder to adaptively recalibrate feature maps by emphasizing task-relevant channels.
  • Replaces the standard transition and output layers with atrous spatial pyramid pooling (ASPP) to capture multi-scale contextual information through parallel dilated convolutions with different rates.
  • Replaces standard convolutional blocks with residual blocks to enable deeper network architectures and alleviate the vanishing gradient problem during training.
  • Combines the three components—SE, ASPP, and residual learning—into a unified U-Net-based architecture named SAR-U-Net for end-to-end liver segmentation.
  • Trains the network using standard supervised learning with cross-entropy and dice loss on two public liver CT datasets.

Experimental results

Research questions

  • RQ1Can the integration of SE blocks improve feature representation in liver CT segmentation by focusing on relevant channels?
  • RQ2Does ASPP enhance segmentation performance by capturing multi-scale contextual features in liver CT images?
  • RQ3Can residual learning enable deeper and more accurate U-Net architectures without degradation?
  • RQ4How does SAR-U-Net compare to existing 2D-based models in terms of segmentation accuracy and robustness on challenging liver CT cases?

Key findings

  • On the LiTS17 dataset, SAR-U-Net achieved a mean Dice score of 95.71%, outperforming other 2D-based models in segmentation accuracy.
  • On LiTS17, the model recorded a mean VOE of 9.52%, RVD of -0.84%, ASD of 1.54 mm, and MSD of 29.14 mm, indicating high overlap and low surface distance errors.
  • On the SLiver07 dataset, SAR-U-Net achieved the highest Dice score of 97.31% among comparable models, with VOE of 5.37%, RVD of -1.08%, ASD of 1.85 mm, and MSD of 27.45 mm.
  • The model demonstrated strong robustness in handling challenging cases such as small liver regions, discontinuous liver structures, and fuzzy boundaries.
  • The combination of SE, ASPP, and residual learning significantly improved segmentation performance compared to standard U-Net and related architectures.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.