[Paper Review] Scheme for femtosecond-resolution pump-probe experiments at XFELs with two-color ten GW-level X-ray pulses

Gianluca Geloni, Vitali Kocharyan|arXiv (Cornell University)|Jan 20, 2010
Advanced X-ray Imaging TechniquesPhysics and Astronomy2 references10 citations
TL;DR

This paper proposes a femtosecond-resolution pump-probe scheme at XFELs using two-color, ten GW-level X-ray pulses derived from a single electron bunch via a modified undulator setup. By replacing one undulator segment with a magnetic chicane that delays half the bunch, the method enables simultaneous generation of two synchronized, high-peak-power X-ray pulses at different wavelengths with sub-10 fs resolution and zero timing jitter.

ABSTRACT

This paper describes a scheme for pump-probe experiments that can be performed at LCLS and at the European XFEL and determines what additional hardware development will be required to bring these experiments to fruition. It is proposed to derive both pump and probe pulses from the same electron bunch, but from different parts of the tunable-gap baseline undulator. This eliminates the need for synchronization and cancels jitter problems. The method has the further advantage to make a wide frequency range accessible at high peak-power and high repetition-rate. An important feature of the proposed scheme is that the hardware requirement is minimal. Our technique is based in essence on the "fresh" bunch technique. For its implementation it is sufficient to substitute a single undulator module with short magnetic delay line, i.e. a weak magnetic chicane, which delays the electron bunch with respect to the SASE pulse of half of the bunch length in the linear stage of amplification. This installation does not perturb the baseline mode of operation. We present a feasibility study and we make exemplifications with the parameters of the SASE2 line of the European XFEL.

Motivation & Objective

  • Enable pump-probe experiments at XFELs with sub-10 fs temporal resolution using two-color X-ray pulses.
  • Overcome the challenge of precise synchronization between pump and probe pulses in X-ray pump-probe experiments.
  • Minimize hardware modifications by leveraging existing beam dynamics and undulator infrastructure.
  • Achieve high peak power (ten GW-level) and high repetition rate for time-resolved studies of ultrafast dynamics.
  • Ensure compatibility with baseline XFEL operation modes without compromising machine performance.

Proposed method

  • Use a single electron bunch to generate both pump and probe pulses via a two-stage FEL process in a tunable-gap undulator.
  • Replace one undulator segment with a short magnetic chicane (weak chicane) to delay half the electron bunch by approximately half its length.
  • The first half of the bunch is seeded and amplifies to saturation in the first undulator segment, producing a short, high-power SASE pulse.
  • The second half of the bunch remains unmodulated and lases at a different wavelength in the third segment, producing the probe pulse.
  • Utilize the fresh-bunch technique to maintain high gain and coherence in the second lasing process.
  • Separate the two-color pulses using X-ray mirrors installed within the magnetic chicane to achieve spatial and angular separation at the experimental station.

Experimental results

Research questions

  • RQ1Can a single electron bunch generate two temporally distinct, high-peak-power X-ray pulses at different wavelengths with femtosecond precision?
  • RQ2How can timing jitter between pump and probe pulses be eliminated in XFEL-based pump-probe experiments?
  • RQ3What minimal hardware modifications are required to implement a two-color, femtosecond X-ray source at XFEL facilities?
  • RQ4Is the proposed scheme compatible with both short-pulse and long-pulse operation modes of XFELs?
  • RQ5Can the two-color X-ray pulses be efficiently separated and delivered to the experimental station without significant photon loss?

Key findings

  • The method achieves sub-10 fs temporal resolution with two-color, ten GW-level X-ray pulses generated from a single electron bunch.
  • The use of a single magnetic chicane to delay half the bunch eliminates timing jitter between pump and probe pulses.
  • The scheme is feasible in the short-pulse mode of operation, as demonstrated with SASE2 parameters at the European XFEL (17.5 GeV, 0.025 nC, 1.0 μm bunch length).
  • The technique maintains baseline operation compatibility and poses no risk to machine performance.
  • Spatial separation of the two pulses is achieved via X-ray mirrors installed in the chicane, enabling a few mm separation at the experimental station with minimal loss.
  • The method is also applicable to long-pulse mode (60 fs) by increasing the chicane angle to 2.5 mrad or using an optical delay line, maintaining low heat loading due to linear regime operation.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.