Skip to main content
QUICK REVIEW

[Paper Review] Search for low-mass dark matter with the DAMIC experiment

M. Settimo|arXiv (Cornell University)|Mar 20, 2020
Dark Matter and Cosmic PhenomenaPhysics and Astronomy2 references15 citations
TL;DR

This paper presents the DAMIC experiment’s search for low-mass dark matter using thick, fully depleted CCDs as ultra-low-noise detectors sensitive to electron and nuclear recoils below 10 GeV. With a 40g detector at SNOLAB and a new 1kg DAMIC-M detector using skipper-CCDs under development at Modane, the experiment achieves sub-electron energy resolution and sets stringent limits on dark matter-electron scattering and hidden-photon absorption, significantly constraining sub-GeV dark matter models.

ABSTRACT

The DAMIC (Dark Matter in CCDs) experiment searches for the interactions of dark matter particles with the nuclei and the electrons in the silicon bulk of thick fully depleted charge-coupled devices (CCDs). Because of the low noise and low dark current, DAMIC CCDs are sensitive to the ionization signals expected from low-mass dark matter particles ($< 10$ GeV). A 40-gram target detector has collected data at the SNOLAB underground laboratory since 2017. Recent results from the searches for DM-electron scattering and hidden-photon absorption will be summarized and the status of WIMPs-nucleon search reported. A new detector -- DAMIC-M (DAMIC at Modane) -- with a mass-size of 1 kg and improved CCD readout is under design and will be installed at the underground laboratory of Modane, in France. The current status of DAMIC-M and the near future plans will be presented.

Motivation & Objective

  • To search for low-mass dark matter particles, including sub-GeV WIMPs and hidden-sector candidates, via their interactions with electrons and nuclei in silicon CCDs.
  • To reduce background levels in silicon-based detectors through improved material selection, shielding, and background identification using 3D event reconstruction.
  • To develop and deploy a next-generation detector, DAMIC-M, with skipper-CCD technology to achieve sub-electron energy resolution and probe previously inaccessible parameter space for dark matter.
  • To measure intrinsic radioactivity in CCDs, including Si-32 and Pb-210, and constrain their impact on low-energy sensitivity.
  • To test and validate the performance of skipper-CCDs for future dark matter detection with energy thresholds below 3 eV ee.

Proposed method

  • Utilizes thick, fully depleted charge-coupled devices (CCDs) with 15×15 μm² pixels and 675 μm thickness as target and sensor for dark matter interactions.
  • Employs non-destructive, repetitive readout of pixel charge in skipper-CCDs to achieve sub-electron energy resolution (0.07 e− measured).
  • Uses 3D reconstruction of ionization charge diffusion to identify interaction depth and distinguish surface from bulk events, enabling background rejection.
  • Applies spatial coincidence analysis of alpha, beta, and gamma decays to measure U/Th and Pb-210 contamination in the CCD bulk and surfaces.
  • Implements background mitigation strategies including radon-free cleanroom assembly, low-background materials (e.g., electro-formed copper), and shielding to reduce cosmogenic activation.
  • Calibrates ionization response using mono-energetic X- and γ-ray sources and cosmic muons to determine charge diffusion parameters and energy scale.

Experimental results

Research questions

  • RQ1What are the limits on dark matter-electron scattering for dark matter masses between 0.6 MeV and 6 MeV?
  • RQ2How does the presence of Si-32 and Pb-210 in the CCD bulk and surfaces affect the sensitivity of low-mass dark matter searches?
  • RQ3To what extent can skipper-CCD technology reduce the energy threshold and improve sensitivity to sub-GeV dark matter particles?
  • RQ4What is the contribution of hidden-photon absorption to the background, and how can it be constrained?
  • RQ5Can the background model from DAMIC at SNOLAB be extrapolated to guide the design and operation of DAMIC-M at Modane?

Key findings

  • The DAMIC experiment has measured a Si-32 contamination of 133.3 ± 27.8 μBq/kg and Pb-210 of 83.1 ± 11.8 nBq/cm² in the CCD bulk, significantly reduced from previous prototypes.
  • The U-238 and Th-232 decay chains were constrained to less than 0.53 /kg/day and 0.35 /kg/day, respectively, based on the absence of α-β and two-α coincidences.
  • DAMIC set 90% confidence level limits on the dark matter-electron scattering cross section for dark matter masses between 0.6 MeV and 6 MeV, excluding a large region of parameter space.
  • A prototype skipper-CCD achieved a single-electron resolution of 0.07 e−, demonstrating the feasibility of sub-electron energy resolution for low-mass dark matter detection.
  • The DAMIC-M detector is expected to achieve an energy threshold of 2–3 electrons (~3 eV ee) with a 1 kg silicon target and improved background suppression.
  • The projected sensitivity of DAMIC-M for WIMPs-nucleon cross section reaches the irreducible background level, enabling exploration of the hidden sector for mediators with masses from 1 MeV/c² to 1 GeV/c².

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.