[Paper Review] Search for the Migdal effect in liquid xenon with keV-level nuclear recoils
This study presents the first direct experimental search for the Migdal effect in liquid xenon using keV-level nuclear recoils from tagged 14.1 MeV neutron scattering. Despite low background rates, no significant signal was observed, suggesting possible overestimation of Migdal ionization rates or enhanced electron-ion recombination in liquid xenon, with implications for low-mass dark matter detection sensitivity.
The Migdal effect predicts that a nuclear recoil interaction can be accompanied by atomic ionization, allowing many dark matter direct detection experiments to gain sensitivity to sub-GeV masses. We report the first direct search for the Migdal effect for M- and L-shell electrons in liquid xenon using 7.0$\pm$1.6 keV nuclear recoils produced by tagged neutron scatters. Despite an observed background rate lower than that of expected signals in the region of interest, we do not observe a signal consistent with predictions. We discuss possible explanations, including inaccurate predictions for either the Migdal rate or the signal response in liquid xenon. We comment on the implications for direct dark-matter searches and future Migdal characterization efforts.
Motivation & Objective
- To directly test the existence of the Migdal effect in liquid xenon, where nuclear recoils induce atomic ionization and subsequent electron recoils.
- To assess the viability of the Migdal effect as a detection mechanism for sub-GeV dark matter in dual-phase xenon time projection chambers.
- To evaluate whether current theoretical predictions of Migdal ionization rates in liquid xenon are accurate, given the lack of observed signal.
- To investigate whether enhanced electron-ion recombination in liquid xenon could suppress the detectable ionization signal from Migdal events.
- To establish a low-background experimental baseline for future characterization of the Migdal effect in liquid xenon detectors.
Proposed method
- Used a compact dual-phase xenon time projection chamber (TPC) to detect both scintillation (S1) and ionization (S2) signals from nuclear recoils.
- Employed tagged 14.1 MeV neutrons to produce keV-level nuclear recoils with known kinematics, enabling precise reconstruction of recoil energy and angle.
- Selected events with nuclear recoil energies of $7.0 \pm 1.6\ \text{keV}$ to target the regime where Migdal ionization is predicted to produce measurable electron recoil signals.
- Performed S1-S2 discrimination to separate electron recoil (ER) signals from nuclear recoil (NR) backgrounds, focusing on the region of interest (ROI) for Migdal-induced ERs.
- Calculated expected Migdal signal rates using theoretical models from Ibe et al. (2018) and Adams et al. (2023), incorporating atomic data and electron shell ionization probabilities.
- Quantified background contributions from neutron multiple scattering (NMS) and potential pile-up (PS), finding them below 0.1 counts in the ROI.
Experimental results
Research questions
- RQ1Does the Migdal effect produce a detectable electron recoil signal in liquid xenon when induced by keV-level nuclear recoils?
- RQ2Are current theoretical predictions of Migdal ionization rates in liquid xenon consistent with experimental observations?
- RQ3Could enhanced electron-ion recombination in liquid xenon suppress the ionization signal from Migdal events, leading to a null result despite the presence of the effect?
- RQ4What is the role of track proximity between nuclear and electron recoils in altering signal detection efficiency in liquid xenon?
- RQ5Can the observed tension between predicted and observed signal rates be resolved by re-evaluating either the Migdal rate or the detector response function?
Key findings
- No significant signal was observed in the region of interest (ROI), with a measured background rate of $0.9 \pm 0.9$ counts, significantly below the expected signal rate.
- The observed signal-to-noise ratio (SNR) exceeds 1, indicating a tension between theoretical predictions and experimental data, though low statistics limit statistical power.
- Background contributions from neutron multiple scattering (NMS) and pile-up (PS) were estimated at less than 0.1 counts each, confirming the experiment's low-background capability.
- The null result suggests that either the predicted Migdal ionization rate in liquid xenon may be overestimated, or recombination effects are suppressing detectable ionization signals.
- The proximity of nuclear and electron recoil tracks in Migdal events may enhance recombination, reducing the S2 signal by up to a factor of two compared to isolated electron recoils.
- The study establishes a critical experimental benchmark for future Migdal effect characterization, highlighting the need for first-principles simulations of recombination in liquid xenon.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.