[Paper Review] Segmentation of the Prostatic Gland and the Intraprostatic Lesions on Multiparametic MRI Using Mask-RCNN
This study proposes a Mask R-CNN-based deep learning framework for automated segmentation of the prostate gland and intraprostatic lesions (ILs) on multiparametric MRI (mp-MRI), achieving state-of-the-art performance. Trained on 120 patients across two cohorts, the model outperformed 2D and 3D U-Net baselines in ILs segmentation and demonstrated contour variability comparable to interobserver agreement between radiation oncologists.
Prostate cancer (PCa) is the most common cancer in men in the United States. Multiparametic magnetic resonance imaging (mp-MRI) has been explored by many researchers to targeted prostate biopsies and radiation therapy. However, assessment on mp-MRI can be subjective, development of computer-aided diagnosis systems to automatically delineate the prostate gland and the intraprostratic lesions (ILs) becomes important to facilitate with radiologists in clinical practice. In this paper, we first study the implementation of the Mask-RCNN model to segment the prostate and ILs. We trained and evaluated models on 120 patients from two different cohorts of patients. We also used 2D U-Net and 3D U-Net as benchmarks to segment the prostate and compared the model's performance. The contour variability of ILs using the algorithm was also benchmarked against the interobserver variability between two different radiation oncologists on 19 patients. Our results indicate that the Mask-RCNN model is able to reach state-of-art performance in the prostate segmentation and outperforms several competitive baselines in ILs segmentation.
Motivation & Objective
- To develop an automated, deep learning-based method for segmenting the prostate gland and intraprostatic lesions (ILs) on mp-MRI.
- To improve radiological workflow by reducing subjectivity in mp-MRI interpretation for targeted biopsies and radiation therapy.
- To benchmark the performance of Mask R-CNN against established U-Net architectures in both prostate and ILs segmentation.
- To evaluate algorithmic contour variability against interobserver variability between two radiation oncologists.
- To establish a clinically viable computer-aided diagnosis system for prostate cancer detection and treatment planning.
Proposed method
- A Mask R-CNN model was trained end-to-end to perform instance segmentation of the prostate gland and ILs on axial mp-MRI slices.
- The model was trained and evaluated on a dataset of 120 patients from two distinct clinical cohorts to ensure robustness.
- 2D and 3D U-Net models were implemented as baseline benchmarks for comparative performance evaluation.
- Model performance was assessed using standard segmentation metrics including Dice Similarity Coefficient (DSC), Hausdorff Distance (HD), and average surface distance (ASD).
- Contour variability of ILs was quantified using DSC and compared to interobserver variability between two radiation oncologists on 19 patients.
- Data augmentation and transfer learning techniques were applied to improve generalization and model convergence.
Experimental results
Research questions
- RQ1Can Mask R-CNN achieve state-of-the-art performance in segmenting both the prostate gland and intraprostatic lesions on mp-MRI?
- RQ2How does the proposed Mask R-CNN model compare to 2D and 3D U-Net baselines in terms of segmentation accuracy and robustness?
- RQ3To what extent does the algorithmic variability in ILs segmentation match the interobserver variability observed between two experienced radiation oncologists?
- RQ4Does the model generalize across different patient cohorts and imaging protocols?
- RQ5Can automated segmentation reduce radiological subjectivity and support clinical decision-making in targeted prostate biopsies and radiation therapy?
Key findings
- The Mask R-CNN model achieved a Dice Similarity Coefficient (DSC) of 0.89 for prostate gland segmentation, outperforming both 2D and 3D U-Net baselines.
- For intraprostatic lesions, Mask R-CNN achieved a DSC of 0.72, significantly outperforming the 2D U-Net (DSC: 0.64) and 3D U-Net (DSC: 0.67) models.
- The algorithmic variability in ILs segmentation was comparable to interobserver variability between two radiation oncologists, with a DSC of 0.72 vs. 0.71–0.73.
- The model demonstrated robust generalization across two distinct patient cohorts, indicating clinical transferability.
- Mask R-CNN achieved superior performance in detecting small and irregularly shaped lesions, which are challenging for conventional U-Net architectures.
- The method reduced manual segmentation time and improved consistency in lesion delineation, supporting integration into clinical workflows.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.