[Paper Review] SegTHOR: Segmentation of Thoracic Organs at Risk in CT images
This paper introduces SegTHOR, a public dataset of 60 thoracic CT scans with manual contours of four organs at risk (heart, trachea, aorta, esophagus) for radiotherapy planning. Using a simplified U-Net architecture with dropout and bilinear upsampling, the study achieves Dice scores of 0.93 for heart and 0.86 for trachea, with notable improvements when evaluating only on slices with ground truth, highlighting room for improvement in segmenting small, low-contrast organs like the esophagus.
In the era of open science, public datasets, along with common experimental protocol, help in the process of designing and validating data science algorithms; they also contribute to ease reproductibility and fair comparison between methods. Many datasets for image segmentation are available, each presenting its own challenges; however just a very few exist for radiotherapy planning. This paper is the presentation of a new dataset dedicated to the segmentation of organs at risk (OARs) in the thorax, i.e. the organs surrounding the tumour that must be preserved from irradiations during radiotherapy. This dataset is called SegTHOR (Segmentation of THoracic Organs at Risk). In this dataset, the OARs are the heart, the trachea, the aorta and the esophagus, which have varying spatial and appearance characteristics. The dataset includes 60 3D CT scans, divided into a training set of 40 and a test set of 20 patients, where the OARs have been contoured manually by an experienced radiotherapist. Along with the dataset, we present some baseline results, obtained using both the original, state-of-the-art architecture U-Net and a simplified version. We investigate different configurations of this baseline architecture that will serve as comparison for future studies on the SegTHOR dataset. Preliminary results show that room for improvement is left, especially for smallest organs.
Motivation & Objective
- To address the lack of publicly available, standardized datasets for thoracic organs at risk (OARs) segmentation in radiotherapy.
- To provide a benchmark dataset with high-quality manual contours for four key OARs: heart, trachea, aorta, and esophagus.
- To establish baseline performance using state-of-the-art and simplified U-Net architectures on the SegTHOR dataset.
- To enable fair comparison and reproducibility in medical image segmentation research for radiotherapy applications.
- To identify challenges in segmenting small, low-contrast organs such as the esophagus, which are critical for accurate dose planning.
Proposed method
- The SegTHOR dataset comprises 60 3D CT scans from lung and Hodgkin’s lymphoma patients, acquired with varying slice counts (150–284) and resolutions (0.90–1.37 mm in-plane, 2–3.7 mm slice thickness).
- Manual segmentation of OARs was performed by an experienced radiotherapist using the SomaVision platform, with contours defined according to clinical guidelines.
- Baseline models were trained using a simplified U-Net (sU-Net) with dropout regularization and two upsampling strategies: transposed convolution and bilinear interpolation.
- The study evaluated segmentation performance using Dice coefficient and Average Hausdorff Distance (AHD), comparing results on the full dataset and on a restricted subset where ground truth was available.
- Evaluation was conducted on both original and restricted slice ranges to assess the impact of mislabeling in regions without ground truth.
- A new evaluation protocol was introduced on the Codalab platform to support two evaluation modes: full-slice and ground-truth-only.
Experimental results
Research questions
- RQ1How does model performance on the SegTHOR dataset vary when evaluating on all slices versus only slices with available ground truth annotations?
- RQ2What is the impact of architectural simplification and dropout regularization on segmentation accuracy for small and low-contrast thoracic OARs?
- RQ3Which upsampling method—transposed convolution or bilinear interpolation—yields better performance and efficiency in this segmentation task?
- RQ4To what extent does the choice of network depth and feature map count affect generalization, especially for organs like the esophagus with high anatomical variability?
- RQ5How do baseline results on SegTHOR compare to state-of-the-art models, and what performance gaps remain for critical OARs?
Key findings
- The simplified U-Net with dropout and bilinear upsampling achieved a Dice score of 0.93 ± 0.03 for the heart and 0.86 ± 0.04 for the trachea on the full dataset.
- For the esophagus, the Dice score was 0.81 ± 0.06 on the full dataset, improving to 0.83 ± 0.06 when evaluated only on slices with ground truth.
- The Average Hausdorff Distance (AHD) for the trachea decreased significantly from 1.08 ± 0.85 to 0.15 ± 0.09 when restricted to ground-truth-labeled slices, indicating improved spatial accuracy.
- The aorta achieved a Dice score of 0.92 ± 0.02 and AHD of 0.52 ± 0.66 on the full dataset, improving to 0.93 ± 0.02 and 0.19 ± 0.31 on the restricted set.
- Bilinear upsampling outperformed transposed convolution in terms of Dice and AHD, and was preferred due to lower computational cost.
- The study identified that the esophagus remains the most challenging structure due to low contrast and high anatomical variability, with significant room for improvement in segmentation accuracy.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.