[Paper Review] Self-supervised Mean Teacher for Semi-supervised Chest X-ray Classification
This paper proposes S²MTS², a self-supervised mean-teacher framework for semi-supervised chest X-ray classification that combines joint contrastive learning (JCL) with exponential moving average teacher training. By leveraging unlabelled data through infinite positive feature pairs in pre-training and consistency regularization in fine-tuning, S²MTS² achieves state-of-the-art performance on ChestX-ray14, CheXpert, and ISIC2018, outperforming prior methods by large margins even with limited labelled data.
The training of deep learning models generally requires a large amount of annotated data for effective convergence and generalisation. However, obtaining high-quality annotations is a laboursome and expensive process due to the need of expert radiologists for the labelling task. The study of semi-supervised learning in medical image analysis is then of crucial importance given that it is much less expensive to obtain unlabelled images than to acquire images labelled by expert radiologists. Essentially, semi-supervised methods leverage large sets of unlabelled data to enable better training convergence and generalisation than using only the small set of labelled images. In this paper, we propose Self-supervised Mean Teacher for Semi-supervised (S$^2$MTS$^2$) learning that combines self-supervised mean-teacher pre-training with semi-supervised fine-tuning. The main innovation of S$^2$MTS$^2$ is the self-supervised mean-teacher pre-training based on the joint contrastive learning, which uses an infinite number of pairs of positive query and key features to improve the mean-teacher representation. The model is then fine-tuned using the exponential moving average teacher framework trained with semi-supervised learning. We validate S$^2$MTS$^2$ on the multi-label classification problems from Chest X-ray14 and CheXpert, and the multi-class classification from ISIC2018, where we show that it outperforms the previous SOTA semi-supervised learning methods by a large margin.
Motivation & Objective
- To address the high cost of expert-annotated medical images by improving semi-supervised learning (SSL) in chest X-ray classification.
- To overcome limitations in existing SSL methods that underutilize unlabelled data during fine-tuning or rely on finite positive pairs in self-supervised pre-training.
- To develop a novel framework that integrates self-supervised pre-training with consistency-based student-teacher learning for improved representation and generalization.
- To validate the method on multi-label (ChestX-ray14, CheXpert) and multi-class (ISIC2018) medical imaging benchmarks with varying labelled data ratios.
Proposed method
- The method uses joint contrastive learning (JCL) to generate an infinite number of positive feature pairs from unlabelled images, improving representation learning during self-supervised pre-training.
- A student-teacher model is trained using exponential moving average (EMA) of the student's weights to form a robust teacher network, enforcing prediction consistency.
- The self-supervised pre-training phase minimizes a contrastive loss over infinite positive pairs of query and key features extracted from unlabelled data.
- Fine-tuning employs a dual loss: cross-entropy loss on labelled data and consistency loss between student and teacher predictions on unlabelled data.
- The framework combines S4L (self-supervised pre-training) with consistency-enforcing SSL, enabling better generalization than prior SOTA methods.
- The model is trained end-to-end with a ResNet or DenseNet backbone, and the final classifier is fine-tuned using both labelled and unlabelled data.
Experimental results
Research questions
- RQ1Can self-supervised pre-training with infinite positive feature pairs improve representation learning in semi-supervised chest X-ray classification?
- RQ2Does combining self-supervised pre-training with mean-teacher consistency regularization lead to better performance than existing SOTA SSL methods?
- RQ3How do the individual components—self-supervised learning, JCL, and mean-teacher fine-tuning—contribute to overall performance?
- RQ4Can the proposed method achieve SOTA results even in fully-supervised settings when fine-tuned on 100% of labels?
Key findings
- On ChestX-ray14 with 20% labelled data, S²MTS² achieves a mean AUC of 81.06%, outperforming previous SOTA methods by 0.5–1.5 percentage points.
- On CheXpert, S²MTS² achieves a mean AUC of 94.71%, surpassing the previous SOTA (93.58%) by 1.13 points.
- On ISIC2018 with 20% labelled data, S²MTS² achieves an F1 score of 62.67%, a 3.57-point improvement over the prior SOTA (59.10).
- The ablation study confirms that each component—self-supervised learning, JCL, and mean-teacher—contributes significantly, with the full model improving mean AUC by 2.7% over baseline.
- Even when trained on 100% of the labelled data, S²MTS² achieves a mean AUC of 71.58% on ChestX-ray14, outperforming supervised SOTA methods.
- The method demonstrates robustness across different data splits and label ratios, showing consistent gains in AUC, F1, and sensitivity across all benchmarks.
Read this paper