Skip to main content
QUICK REVIEW

[Paper Review] Shesop Healthcare: Android application to monitor heart rate variance, display influenza and stress condition using Polar H7

Andrien Ivander Wijaya, Ary Setijadi Prihatmanto|arXiv (Cornell University)|Jan 1, 2016
Heart Rate Variability and Autonomic ControlMedicine8 references4 citations
TL;DR

This paper presents Shesop, an Android application that uses real-time heart rate and heart rate variability (HRV) data from the Polar H7 chest strap to classify stress and influenza conditions. Developed using Android Studio, the app integrates Bluetooth Low Energy (BLE) for data acquisition, applies HRV analysis (time and non-linear domains), and employs SVM classification to assess health states, with results visualized and saved via Dropbox.

ABSTRACT

Shesop is an integrated system to make human lives more easily and to help people in terms of healthcare. Stress and influenza classification is a part of Shesop's application for a healthcare devices such as smartwatch, polar and fitbit. The main objective of this paper is to create a proper application to implement the stress and influenza classification. The application use Android studio, XML and Java. Also, while creating this application, all design and program is considered to be available for future updates. The application needs an android smartphone with Bluetooth Low Energy technology (bluetooth v4.0 or above). SheSop application will accommodate data entry, device picker, data gathering process, result and saving the result. In the end, we could use the polar H7 and this application to get a real-time heart rate, Heart rate variability and diagnose our stress and influenza condition.

Motivation & Objective

  • To develop an accessible, real-time mobile application for monitoring stress and influenza using physiological signals.
  • To integrate HRV analysis from Polar H7 data into a user-friendly Android interface.
  • To enable classification of stress and influenza states using machine learning (SVM) on HRV metrics.
  • To ensure scalability and maintainability through modular design and clean code for future updates.
  • To support user data persistence and cloud backup via Dropbox integration.

Proposed method

  • The application is built using Android Studio with Java and XML for UI and logic.
  • Bluetooth Low Energy (BLE) v4.0+ is used to stream real-time heart rate and RR interval (IBI) data from the Polar H7.
  • HRV features are extracted from IBI data, including time-domain (mean, SDNN), Poincaré plot, and non-linear metrics.
  • A Support Vector Machine (SVM) classifier is implemented to distinguish between stress and influenza states based on HRV patterns.
  • The app includes a data input module for user-specific parameters (e.g., systolic/diastolic pressure, temperature) to improve classification accuracy.
  • Results are displayed in real time, with options to save data locally and upload to Dropbox for long-term storage and analysis.

Experimental results

Research questions

  • RQ1Can real-time HRV data from a Polar H7 chest strap be effectively used to classify stress and influenza conditions in a mobile application?
  • RQ2How can HRV metrics (time-domain, Poincaré, non-linear) be integrated into a lightweight Android app for clinical-like assessment?
  • RQ3What role do user-input parameters (e.g., blood pressure, temperature) play in improving classification accuracy?
  • RQ4How can an Android-based system ensure usability, performance, and scalability for future health monitoring extensions?
  • RQ5To what extent does the app’s design support secure, efficient, and maintainable software development for healthcare applications?

Key findings

  • The Shesop application successfully collects real-time heart rate and IBI data from the Polar H7 via BLE on Android devices with API 18+.
  • HRV features including mean RR interval, standard deviation (SDNN), and Poincaré plot parameters were extracted and used for classification.
  • The app achieved functional classification of stress and influenza states using an SVM model trained on HRV data.
  • User input for systolic/diastolic pressure and temperature was integrated and used to enhance classification context.
  • The application passed all UX, performance, and stability testing (e.g., UX-B1, PS-P1) and supports data export to Dropbox.
  • The app is designed for extensibility, with a modular architecture supporting future updates and integration of new health conditions.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.