[Paper Review] Simultaneous lesion and neuroanatomy segmentation in Multiple Sclerosis using deep neural networks
This study proposes a deep learning framework using 3D-to-2D convolutional neural networks (DeepSCAN) for simultaneous segmentation of multiple sclerosis lesions and brain structures in multi-contrast MRI. The method achieves human-rater-level agreement on lesion detection and outperforms existing approaches, particularly when trained with additional anatomical labels, demonstrating strong generalization to out-of-center data.
Segmentation of white matter lesions and deep grey matter structures is an important task in the quantification of magnetic resonance imaging in multiple sclerosis. In this paper we explore segmentation solutions based on convolutional neural networks (CNNs) for providing fast, reliable segmentations of lesions and grey-matter structures in multi-modal MR imaging, and the performance of these methods when applied to out-of-centre data. We trained two state-of-the-art fully convolutional CNN architectures on the 2016 MSSEG training dataset, which was annotated by seven independent human raters: a reference implementation of a 3D Unet, and a more recently proposed 3D-to-2D architecture (DeepSCAN). We then retrained those methods on a larger dataset from a single centre, with and without labels for other brain structures. We quantified changes in performance owing to dataset shift, and changes in performance by adding the additional brain-structure labels. We also compared performance with freely available reference methods. Both fully-convolutional CNN methods substantially outperform other approaches in the literature when trained and evaluated in cross-validation on the MSSEG dataset, showing agreement with human raters in the range of human inter-rater variability. Both architectures showed drops in performance when trained on single-centre data and tested on the MSSEG dataset. When trained with the addition of weak anatomical labels derived from Freesurfer, the performance of the 3D Unet degraded, while the performance of the DeepSCAN net improved. Overall, the DeepSCAN network predicting both lesion and anatomical labels was the best-performing network examined.
Motivation & Objective
- To develop a deep learning model that simultaneously segments MS lesions and healthy brain structures in multi-contrast MRI.
- To evaluate performance on out-of-center data to assess transferability and robustness across scanners and sites.
- To investigate whether adding weak anatomical labels improves lesion segmentation performance.
- To compare the proposed method with freely available tools and state-of-the-art models in lesion detection and segmentation.
- To assess the impact of dataset shift and label quality on model generalization.
Proposed method
- Trained two 3D fully convolutional neural network architectures—3D U-Net and DeepSCAN—on the 2016 MSSEG training dataset with seven human raters’ annotations.
- Retrained models on a larger single-center dataset, with and without additional labels for deep grey matter structures.
- Used weak anatomical labels derived from Freesurfer to augment training data for improved generalization.
- Applied multi-task learning to jointly predict lesion and neuroanatomy segmentation masks from T1, FLAIR, and T2-weighted MRI sequences.
- Evaluated performance using Dice coefficient, F1 score for lesion detection, and overlap metrics with consensus ground truth.
- Conducted cross-validation and external testing on the Insel32 and MSSEG datasets to assess transferability.
Experimental results
Research questions
- RQ1Can a single deep learning model achieve high-accuracy simultaneous segmentation of MS lesions and brain structures?
- RQ2How does performance degrade when models trained on single-center data are tested on multi-center data?
- RQ3Does incorporating weak anatomical labels from Freesurfer improve lesion segmentation performance?
- RQ4How does the proposed method compare to freely available tools like LST in terms of detection and segmentation accuracy?
- RQ5To what extent do false positives and false negatives in lesion detection stem from labeling errors rather than model failure?
Key findings
- The DeepSCAN network achieved the highest performance among all models tested, with a Dice coefficient of 0.59 on the MSSEG dataset, approaching inter-rater variability.
- Both CNN architectures outperformed existing methods in cross-validation on the MSSEG dataset, showing agreement with human raters comparable to human inter-rater variability.
- Performance dropped significantly when models trained on single-center data were tested on the MSSEG dataset, indicating domain shift effects.
- Adding Freesurfer-derived anatomical labels improved the performance of DeepSCAN but degraded the 3D U-Net, suggesting architectural sensitivity to auxiliary supervision.
- Of the 777 lesions missed by DeepSCAN, 75% (579) were judged by neuroradiologists as mislabeled by human raters, indicating that many 'false positives' were artifacts or normal structures.
- 137 of the 372 false positive lesions (37%) were genuine lesions missed by raters, highlighting that lesion detection F1 score is a more informative metric than Dice alone.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.