[Paper Review] Single-pass STEM-EMCD on a zone axis using a patterned aperture: progress in experimental and data treatment methods
This paper demonstrates progress toward single-pass STEM-EMCD on a zone-axis using a patterned 8-blade aperture in cubic iron, enabling simultaneous acquisition of EMCD spectra with improved signal-to-noise ratio. By combining advanced data processing—including background subtraction, spectral profile matching, and post-edge normalization—the authors extract orientation- and momentum transfer-dependent EMCD signals, with the strongest signals observed near the Fe [001] zone axis at high qy values.
Measuring magnetic moments in ferromagnetic materials with atomic column resolution is theoretically possible using the electron magnetic circular dichroism (EMCD) technique in a (scanning) transmission electron microscope ((S)TEM). However, experimental and data processing hurdles currently hamper the realization of this goal. Experimentally, the sample must be tilted to a zone-axis orientation, yielding a complex distribution of magnetic scattering intensity, and the same sample region must be scanned multiple times with sub-atomic spatial registration necessary at each pass. Furthermore, the weak nature of the EMCD signal requires advanced data processing techniques to reliably detect and quantify the result. In this manuscript, we detail our experimental and data processing progress towards achieving single-pass zone-axis EMCD using a patterned aperture. First, we provide a comprehensive data acquisition and analysis strategy for this and other EMCD experiments that should scale down to atomic resolution experiments. Second, we demonstrate that, at low spatial resolution, promising EMCD candidate signals can be extracted, and that these are sensitive to both crystallographic orientation and momentum transfer.
Motivation & Objective
- To achieve single-pass STEM-EMCD on a zone axis using a patterned aperture, overcoming limitations of multi-pass acquisition.
- To improve the signal-to-noise ratio of the weak EMCD signal by utilizing a larger fraction of inelastically scattered electrons.
- To develop a robust data processing pipeline capable of extracting subtle EMCD signals from complex magnetic scattering patterns on zone axes.
- To investigate the dependence of EMCD signal strength and sign on crystallographic orientation and momentum transfer (qy).
Proposed method
- Implementation of an 8-blade mirror-symmetric patterned aperture aligned with the EELS spectrometer's dispersion axis to collect EMCD signals in a single scan pass.
- Use of a non-Cs-corrected JEOL 2100F TEM with a 2 nA probe current to maximize signal-to-noise ratio, despite larger probe size.
- Acquisition of convergent beam electron diffraction (CBED) patterns alongside EELS spectra to correlate local crystallographic orientation with EMCD response.
- Application of a multi-step data processing pipeline: pre-edge background subtraction using inverse power law model (Eq. 6), spectral profile matching via second derivative scaling (Eq. 7), and Fourier-based spectral shift correction.
- Post-edge normalization using linear regression of the ratio between chiral plus and modified chiral minus spectra (Eq. 8), followed by normalization and subtraction to yield fEMCD(E).
- Fitting of the EMCD signal with a two-peak pseudo-Voigt model (Eq. 9) using nonlinear optimization (fmincon) with 17 adjustable parameters, including amplitude, center, broadening, and mixing parameter η.
Experimental results
Research questions
- RQ1Can a patterned aperture enable reliable single-pass EMCD acquisition on a zone axis in a cubic ferromagnetic material?
- RQ2How does the EMCD signal strength and sign depend on the momentum transfer vector qy in the non-dispersive direction?
- RQ3To what extent does crystallographic orientation, particularly proximity to the [001] zone axis, influence the detectability of the EMCD signal?
- RQ4Can advanced data processing mitigate spectral distortions from spectrometer aberrations and enable accurate EMCD signal extraction?
- RQ5Is there evidence of signal inversion (e.g., sign reversal on Fe L3 not mirrored on L2) that may indicate experimental artifacts or physical effects?
Key findings
- Promising EMCD candidate signals were successfully extracted at low spatial resolution, with the strongest signals observed at high qy values and when the sample was oriented close to the Fe [001] zone axis.
- The EMCD signal strength diminished when including a broader range of crystallographic orientations, indicating strong dependence on crystal alignment relative to the aperture and momentum transfer.
- An inversion in signal sign was observed on the Fe L3 edge that was not reciprocated on the L2 edge, suggesting experimental artifacts related to spectrometer aberrations or imperfect alignment.
- The data processing pipeline, including second-derivative profile matching and spectral shift correction, significantly improved spectral alignment and enabled reliable signal extraction despite spectral distortions.
- The EMCD signal was found to be sensitive to both momentum transfer (qy) and local crystallographic orientation, validating the hypothesis that patterned apertures can selectively probe specific scattering vectors.
- The full dataset and open-source analysis code are publicly available on Zenodo under a Creative Commons Attribution 4.0 license, enabling reproducibility and further development of single-pass EMCD methods.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.