Skip to main content
QUICK REVIEW

[Paper Review] Sources of Low-Energy Events in Low-Threshold Dark Matter Detectors

Peizhi Du, Daniel Egaña-Ugrinovic|arXiv (Cornell University)|Dec 1, 2020
Dark Matter and Cosmic PhenomenaPhysics and Astronomy156 references9 citations
TL;DR

This paper identifies Cherenkov radiation, transition radiation, and recombination luminescence as major low-energy backgrounds in sub-GeV dark matter detectors, showing they originate from high-energy cosmic or radioactive particles interacting with detector materials. It demonstrates that these processes explain a large fraction of single-electron events in SENSEI, SuperCDMS HVeV, and SuperCDMS SNOLAB, with implications for future detector design and sensitivity limits.

ABSTRACT

We discuss several low-energy backgrounds to sub-GeV dark matter searches, which arise from high-energy particles of cosmic or radioactive origin that interact with detector materials. We focus on Cherenkov radiation, transition radiation, and luminescence or phonons from electron-hole pair recombination, and show that these processes are an important source of backgrounds at both current and planned detectors. We perform detailed analyses of these backgrounds at several existing and proposed experiments. We find that a large fraction of the observed single-electron events in the SENSEI 2020 run originate from Cherenkov photons generated by high-energy events in the Skipper-CCD, and from recombination photons generated in a phosphorus-doped layer of the same instrument. In a SuperCDMS HVeV 2020 run, Cherenkov photons produced in the sensor holders likely explain the origin of most of the events containing 2 to 6 electrons. At SuperCDMS SNOLAB, Cherenkov radiation from radioactive contaminants in Cirlex could dominate the low-energy backgrounds. For EDELWEISS, Cherenkov or luminescence backgrounds are subdominant to their observed event rate, but could still limit the sensitivity of their future searches. We also point out that Cherenkov radiation, transition radiation, and recombination could be a significant source of backgrounds at future experiments aiming to detect dark-matter via scintillation or phonon signals. The implications of our results for sub-GeV dark-matter searches and for the design of future detectors are significant. In particular, several design strategies to mitigate these backgrounds can be implemented, such as minimizing non-conductive materials near the target, implementing active and passive shielding, and using multiple detectors. Finally, we speculate on the implications of our results for the development of quantum computers and neutrino detectors.

Motivation & Objective

  • To identify and quantify low-energy backgrounds in sub-GeV dark matter detectors arising from high-energy particles interacting with detector materials.
  • To investigate the role of Cherenkov radiation, transition radiation, and luminescence from electron-hole recombination as sources of false signals.
  • To assess the impact of these backgrounds on current and future experiments such as SENSEI, SuperCDMS, and EDELWEISS.
  • To provide design recommendations to mitigate these backgrounds in next-generation dark matter detectors.
  • To explore broader implications for quantum computing and neutrino detection technologies.

Proposed method

  • Detailed analysis of background contributions in existing and proposed experiments, including SENSEI, SuperCDMS HVeV, SuperCDMS SNOLAB, and EDELWEISS.
  • Modeling of Cherenkov photon production in detector components such as sensor holders and phosphorus-doped layers.
  • Evaluation of luminescence and phonon signals from electron-hole recombination in semiconductors and insulators.
  • Assessment of transition radiation contributions from high-energy particle interactions in detector materials.
  • Use of experimental event data from SENSEI 2020, SuperCDMS HVeV 2020, and SuperCDMS SNOLAB to trace event origins.
  • Application of shielding and material selection strategies to estimate background suppression potential.

Experimental results

Research questions

  • RQ1What fraction of single-electron events in the SENSEI 2020 run can be attributed to Cherenkov photons from high-energy events in the Skipper-CCD?
  • RQ2To what extent do recombination photons in phosphorus-doped layers contribute to low-energy backgrounds in SENSEI?
  • RQ3What is the origin of 2–6 electron events in the SuperCDMS HVeV 2020 run, and how much is due to Cherenkov radiation in sensor holders?
  • RQ4How do radioactive contaminants in Cirlex material affect low-energy backgrounds in SuperCDMS SNOLAB?
  • RQ5To what extent could Cherenkov or luminescence backgrounds limit the sensitivity of future EDELWEISS searches?

Key findings

  • A large fraction of single-electron events in the SENSEI 2020 run originate from Cherenkov photons generated by high-energy events in the Skipper-CCD.
  • Recombination photons from a phosphorus-doped layer in the SENSEI detector also contribute significantly to low-energy backgrounds.
  • In the SuperCDMS HVeV 2020 run, Cherenkov photons produced in sensor holders likely explain most events with 2 to 6 electrons.
  • At SuperCDMS SNOLAB, Cherenkov radiation from radioactive contaminants in Cirlex material could dominate low-energy backgrounds.
  • For EDELWEISS, while Cherenkov or luminescence backgrounds are subdominant to the observed event rate, they may still limit future sensitivity.
  • Cherenkov radiation, transition radiation, and recombination are expected to be significant background sources in future experiments using scintillation or phonon detection.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.