[Paper Review] Spatially resolving amplitude and phase of light with a reconfigurable photonic integrated circuit
This paper presents a reconfigurable photonic integrated circuit (PIC) that spatially resolves the amplitude and phase of free-space light beams using a mesh of Mach-Zehnder interferometers (MZIs) with grating coupler pixels. By calibrating the system with a single paraxial reference beam, the method enables accurate, wavelength-robust measurements of amplitude and phase across multiple polarization states, achieving high-fidelity reconstruction of complex field distributions even with non-ideal components.
Photonic integrated circuits (PICs) play a pivotal role in many applications. Particularly powerful are circuits based on meshes of reconfigurable Mach-Zehnder interferometers as they enable active processing of light. Various possibilities exist to get light into such circuits. Sampling an electromagnetic field distribution with a carefully designed free-space interface is one of them. Here, a reconfigurable PIC is used to optically sample and process free-space beams so as to implement a spatially resolving detector of amplitudes and phases. In order to perform measurements of this kind we develop and experimentally implement a versatile method for the calibration and operation of such integrated photonics based detectors. Our technique works in a wide parameter range, even when running the chip off the design wavelength. Amplitude, phase and polarization sensitive measurements are of enormous importance in modern science and technology, providing a vast range of applications for such detectors.
Motivation & Objective
- To develop a spatially resolving detector for amplitude and phase of free-space optical beams using a programmable photonic integrated circuit.
- To address the challenge of calibrating integrated photonic detectors with non-ideal components, especially beam splitters deviating from 50:50 ratios.
- To enable polarization-sensitive measurements by leveraging the orientation-defined polarization basis of grating couplers.
- To demonstrate robust operation across a wide parameter range, including off-design wavelengths and imperfect device characteristics.
- To provide a calibration-free, all-integrated platform for quantitative amplitude and phase measurements in applications like nanometrology and optical beam analysis.
Proposed method
- The detector uses a 16-pixel free-space interface composed of radially arranged grating couplers, each sensitive to a specific polarization direction.
- Light from the input beam couples into the PIC via these grating couplers and is routed into a binary-tree mesh of 15 reconfigurable Mach-Zehnder interferometers (MZIs).
- Phase shifts in the MZIs are controlled via titanium nitride heaters, enabling programmable interference and wavefront manipulation.
- A multi-parameter fitting algorithm uses measured output intensities and a transmission matrix model to infer unknown input field amplitudes and phases.
- Calibration is performed using a single paraxial reference beam, determining on-chip parameters such as MZI reflectivity and phase shift per voltage.
- For measurement, the same fitting framework is applied with the input field amplitudes and phases as free parameters, enabling reconstruction of complex field distributions.
Experimental results
Research questions
- RQ1Can a reconfigurable photonic integrated circuit accurately measure the spatial amplitude and phase distribution of a free-space optical beam?
- RQ2How can such a detector be calibrated effectively when components deviate from ideal 50:50 beam splitter ratios?
- RQ3To what extent can the calibration and measurement method tolerate operation off the design wavelength?
- RQ4Can the system perform polarization-sensitive measurements using only the intrinsic orientation of grating couplers as a basis?
- RQ5How robust is the method when applied to beams with different polarization states, including circular and linear polarizations?
Key findings
- The system successfully reconstructed the amplitude and phase distribution of a right-handed circularly polarized Gaussian beam with excellent agreement between measured and theoretical values.
- Measurements for left-handed circular, x-polarized, and y-polarized beams showed strong consistency with theoretical predictions across all tested polarization states.
- The calibration method achieved reliable performance even with beam splitters significantly deviating from 50:50 ratios, demonstrating robustness to fabrication imperfections.
- The method operates effectively across a wide range of wavelengths, including off-design wavelengths, without requiring re-calibration.
- The use of a single reference beam for calibration enables rapid, automated, and mechanically stable system setup without moving parts.
- The approach is scalable and compatible with future integration of polarization-splitting grating couplers and on-chip photodetectors for full system miniaturization.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.