This paper presents a high-accuracy spin-1/2 171Yb optical lattice clock with a fractional frequency uncertainty of 3.4×10⁻¹⁶, achieved by minimizing systematic shifts including blackbody radiation and collisional shifts. The clock uses ultracold, spin-polarized fermions in a 1D optical lattice and measures the 1S₀→³P₀ transition at 578 nm, achieving a measured absolute frequency of 518,295,836,590,865.2(0.7) Hz relative to the NIST-F1 Cs fountain clock.
We experimentally investigate an optical clock based on $^{171}$Yb ($I=1/2$) atoms confined in an optical lattice. We have evaluated all known frequency shifts to the clock transition, including a density-dependent collision shift, with a fractional uncertainty of $3.4 imes 10^{-16}$, limited principally by uncertainty in the blackbody radiation Stark shift. We measured the absolute clock transition frequency relative to the NIST-F1 Cs fountain clock and find the frequency to be 518 295 836 590 865.2(0.7) Hz.
Motivation & Objective
- To develop a high-accuracy optical frequency standard based on the 171Yb isotope with nuclear spin I=1/2.
- To evaluate and minimize all known systematic frequency shifts in a lattice-confined fermionic system.
- To demonstrate the advantages of a spin-1/2 system over higher-spin isotopes in optical lattice clocks, including simpler state preparation and absence of tensor light shifts.
- To achieve competitive frequency stability and accuracy comparable to the best optical and microwave standards.
- To measure the absolute clock transition frequency with high precision using a femtosecond laser frequency comb.
Proposed method
- Trapping and cooling 171Yb atoms via the 399 nm 1S₀→1P₁ and 556 nm 1S₀→3P₁ transitions to prepare a degenerate, ultracold sample.
- Loading the atoms into a 1D, horizontally oriented optical lattice with a depth of 500 E_r, achieving a density of ~10¹¹ cm⁻³ and a temperature of 15 μK.
- Optically pumping the atoms to a single spin sublevel (m_F = ±1/2) with 99% efficiency using 556 nm light to enable spin-polarized, many-body state preparation.
- Performing spectroscopy on the 1S₀→³P₀ clock transition at 578 nm using a π-pulse of 80 ms duration, with probe light pre-stabilized to a high-finesse cavity.
- Applying a small magnetic field (0.11 mT) to resolve Zeeman-split transitions and using a differential measurement scheme to cancel first-order Zeeman shifts.
- Using a femtosecond laser frequency comb to compare the Yb clock frequency to the NIST-F1 Cs fountain clock, enabling precise absolute frequency measurement and systematic uncertainty cancellation.
Experimental results
Research questions
- RQ1Can a 171Yb optical lattice clock based on a spin-1/2 fermionic isotope achieve competitive accuracy and stability compared to existing optical clocks?
- RQ2What are the dominant systematic frequency shifts in a spin-1/2 optical lattice clock, and can they be calibrated or suppressed effectively?
- RQ3How does the use of ultracold, spin-polarized fermions affect the density-dependent collision shift in the 171Yb system?
- RQ4Can the vector polarizability of the 1S₀→³P₀ transition be measured and used to improve shift cancellation in future lattice geometries?
- RQ5What is the absolute frequency of the 171Yb 1S₀→³P₀ clock transition, and how does it compare to the NIST-F1 Cs primary standard?
Key findings
- The 171Yb optical lattice clock achieved a total fractional uncertainty of 3.4×10⁻¹⁶, primarily limited by uncertainty in the blackbody radiation Stark shift.
- The absolute frequency of the 1S₀→³P₀ transition was measured as 518,295,836,590,865.2(0.7) Hz, with a statistical uncertainty of 1.4×10⁻¹⁵.
- A density-dependent collision shift of -16.1×10⁻¹⁶ was observed, persisting even with spin-polarized fermions, indicating Pauli exclusion does not fully suppress shifts in this configuration.
- The vector polarizability of the clock transition was measured as α_v ≈ -0.08 a.u., providing a key parameter for future shift cancellation in higher-dimensional lattices.
- The blackbody radiation Stark shift uncertainty was 2.5×10⁻¹⁶ due to 10% uncertainty in polarizability measurements, highlighting a key limitation for room-temperature operation.
- The clock demonstrated a quality factor of 10¹⁴ with a Fourier-limited linewidth of 5.5 Hz (FWHM) over a 160 ms probe time, indicating high coherence and stability.