SpineNetV2 is a deep learning framework for automated detection, labeling, and radiological grading of vertebral bodies and intervertebral discs in clinical spinal MR scans. It improves upon SpineNetV1 with faster, more robust vertebral detection across multiple fields of view (lumbar, cervical, whole spine) using a deep learning-based vector field regression method, and enhances radiological grading with a ResNet34 backbone to support multiclass central canal stenosis, foraminal stenosis, and disc herniation—achieving inference speeds of ~5 seconds per lumbar scan on GPU, a 60x speedup over the original version.
This technical report presents SpineNetV2, an automated tool which: (i) detects and labels vertebral bodies in clinical spinal magnetic resonance (MR) scans across a range of commonly used sequences; and (ii) performs radiological grading of lumbar intervertebral discs in T2-weighted scans for a range of common degenerative changes. SpineNetV2 improves over the original SpineNet software in two ways: (1) The vertebral body detection stage is significantly faster, more accurate and works across a range of fields-of-view (as opposed to just lumbar scans). (2) Radiological grading adopts a more powerful architecture, adding several new grading schemes without loss in performance. A demo of the software is available at the project website: http://zeus.robots.ox.ac.uk/spinenet2/.
Motivation & Objective
- To develop a faster, more robust, and generalizable system for automated vertebral body detection and labeling in clinical spinal MR scans across diverse anatomical fields of view (lumbar, cervical, thoracic, whole spine).
- To improve radiological grading of intervertebral discs in T2-weighted MR scans by extending the number of grading schemes beyond the original SpineNetV1, including multiclass central canal stenosis, foraminal stenosis, and disc herniation.
- To replace the computationally expensive HOG-based detection pipeline of SpineNetV1 with a deep learning-based approach for improved inference speed and compatibility with open-source frameworks.
- To enable deployment on a wider range of hardware by migrating from MATLAB to open-source Python libraries (e.g., PyTorch, PyDicom), enhancing accessibility and reproducibility.
- To provide a fully automated, end-to-end pipeline from raw DICOM files to structured outputs (CSV/JSON) for clinical research and radiological assessment.
Proposed method
- Uses a deep learning-based vector field regression (VFR) model for vertebral body detection, replacing the HOG-based method of SpineNetV1 for faster and more accurate detection across diverse scan fields of view.
- Applies a convolutional neural network (CNN) for vertebral level labeling, assigning anatomical labels (e.g., L1, L2) to detected vertebrae based on spatial context and intensity patterns.
- Extracts intervertebral volumes (IVVs) by computing the region between adjacent labeled vertebrae, enabling localized radiological grading of each disc.
- Employs a ResNet34 backbone for feature extraction in the radiological grading head, replacing the VGG-F used in SpineNetV1 to improve performance and generalization on complex degenerative changes.
- Uses a multi-head classification head to predict multiple grading schemes simultaneously: Pfirrmann (5-class), disc narrowing (4-class), endplate defects (2-class), marrow changes (2-class), spondylolisthesis (2-class), central canal stenosis (4-class), foraminal stenosis (2-class per side), and disc herniation (2-class).
- Processes large scans by splitting them into overlapping patches, which are processed independently and then merged to reconstruct full-coverage detections and labels.
Experimental results
Research questions
- RQ1Can a deep learning-based vertebral body detection system achieve higher accuracy and speed than traditional HOG-based methods across diverse fields of view in spinal MR scans?
- RQ2Can a unified, end-to-end deep learning pipeline reliably detect and label vertebrae in sagittal MR scans of varying anatomical regions (e.g., cervical, lumbar, whole spine) without requiring region-specific tuning?
- RQ3Does replacing the VGG-F backbone with a deeper ResNet34 architecture significantly improve the performance of radiological grading for complex degenerative changes such as multiclass central canal stenosis and foraminal stenosis?
- RQ4To what extent does the new architecture reduce inference time while maintaining or improving grading accuracy compared to SpineNetV1?
- RQ5Can the system be deployed efficiently in real-world clinical research settings using open-source software and standard hardware, including CPUs and GPUs?
Key findings
- SpineNetV2 reduces inference time for a lumbar scan from ~5 minutes (SpineNetV1) to ~5 seconds on a GPU, representing a 60x speedup in processing time.
- The new VFR-based vertebral detection system achieves faster and more accurate detection across all fields of view (lumbar, cervical, thoracic, whole spine), with improved robustness compared to SpineNetV1’s lumbar-only focus.
- Radiological grading performance on the Genodisc dataset is comparable or slightly improved: SpineNetV2 achieves 95.0% accuracy for spondylolisthesis and 93.2% for central canal stenosis (binary), matching or exceeding SpineNetV1’s performance on existing tasks.
- SpineNetV2 successfully introduces new grading schemes: multiclass central canal stenosis (4-class, 64.9% F1), left/right foraminal stenosis (84.8% and 82.4% F1), and disc herniation (80.4% F1), which were not supported in SpineNetV1.
- Peak GPU memory usage is 1.6GB for lumbar scans and 2.5GB for whole spine scans, indicating efficient memory utilization suitable for clinical deployment.
- On CPU, processing time is 25 seconds for lumbar scans and 120 seconds for whole spine scans, demonstrating that the system remains usable even without GPU acceleration, albeit at reduced speed.