[Paper Review] SST polarization model and polarimeter calibration
This paper presents a five-parameter Mueller matrix model for the Swedish 1-m Solar Telescope (SST) that accurately describes its polarization properties, validated to within 0.4% accuracy across all Stokes parameters. It introduces a calibration method using a rotating quarter-wave plate and linear polarizer to determine the polarimeter's modulation matrix, with CCD non-linearities identified as the primary calibration challenge, enabling first full-Stokes imaging polarimetry at the SST.
A telescope polarization model for the SST [Swedish 1-m Solar Telescope] is developed and the parameters of this model are fitted to polarization measurements made with a 1-meter linear polarizer in front of the entrance window. In this model, the 1-meter lens is characterized by a five-parameter Muller matrix, corresponding to a retarder with arbritary variations of the retardance and fast-axis orientation across the aperture. The resulting model is verified by measuring the telescope polarization for unpolarized input light and comparing to predictions from the polarization model. The accuracy of the prediction is within approximately 0.4% for all normalized polarization components (Q/I, U/I and V/I). The polarimeter used is based on two nematic liquid crystals and one linear polarizer, and will be used for both imaging polarimetry and spectropolarimetry. The most critical calibration is measuring the modulation matrix. This is done by inserting one linear polarizer and one rotating quarter-wave plate in the optical path before the polarimeter, and measuring the modulated intensity. The calibration of the quarter-wave plate is optimized by measuring the linear polarizer only with the polarimeter, and then minimizing the error in degree of polarization plus the residual error for the inversion of the modulation matrix by iteration of the two unknown parameters (retardance and angle offset). We find that small non-linearities in the CCD response is the major obstacle in calibrating the polarimeter. The first full Stokes imaging polarimetry observations at the SST are shown. Comparing images before and after telescope compensation verify the telescope polarization model.
Motivation & Objective
- To develop a comprehensive polarization model for the Swedish 1-m Solar Telescope (SST) that accounts for spatial variations in retardance and fast-axis orientation.
- To calibrate a dual-nematic liquid crystal polarimeter for high-accuracy imaging and spectropolarimetry.
- To minimize errors in polarization measurement by optimizing the calibration of the quarter-wave plate and addressing CCD non-linearities.
- To validate the telescope polarization model using unpolarized light and compare predictions with observations.
- To enable first full-Stokes imaging polarimetry at the SST with reliable polarization calibration.
Proposed method
- Developed a five-parameter Mueller matrix model to represent the SST's polarization response, accounting for spatially varying retardance and fast-axis orientation.
- Calibrated the polarimeter using a combination of a fixed linear polarizer and a rotating quarter-wave plate to measure the modulation matrix.
- Optimized the quarter-wave plate calibration by minimizing the residual error in the degree of polarization and the inversion of the modulation matrix through iterative adjustment of retardance and angle offset.
- Used unpolarized light input to verify the telescope polarization model and validate its predictions against measured data.
- Addressed CCD non-linearities as a dominant error source by analyzing their impact on calibration accuracy.
- Applied the calibrated system to perform first full-Stokes imaging polarimetry at the SST.
Experimental results
Research questions
- RQ1How accurately can a five-parameter Mueller matrix model describe the polarization properties of the SST across its aperture?
- RQ2What is the optimal calibration procedure for a dual-nematic liquid crystal polarimeter with a rotating wave plate?
- RQ3To what extent do CCD non-linearities limit the accuracy of polarimeter calibration?
- RQ4Can the telescope’s intrinsic polarization response be reliably predicted and compensated for using the developed model?
- RQ5How well does the calibrated polarimeter perform in full-Stokes imaging of solar features?
Key findings
- The SST polarization model predicts all normalized Stokes parameters (Q/I, U/I, V/I) with an accuracy of approximately 0.4% when compared to measurements with unpolarized input light.
- The calibration method using a rotating quarter-wave plate and linear polarizer successfully minimized errors in the degree of polarization and modulation matrix inversion.
- CCD non-linearities were identified as the primary obstacle in achieving higher-precision polarimeter calibration.
- The first full-Stokes imaging polarimetry observations at the SST were successfully performed using the calibrated system.
- Comparison of images before and after telescope compensation confirmed the validity and predictive power of the polarization model.