Skip to main content
QUICK REVIEW

[Paper Review] Status of the ArDM Experiment: First results from gaseous argon operation in deep underground environment

ArDM Collaboration, A. Badertscher|arXiv (Cornell University)|Jun 29, 2013
Dark Matter and Cosmic PhenomenaPhysics and Astronomy3 references8 citations
TL;DR

This paper presents the first results from the ArDM experiment's gaseous argon operation at the Canfranc Underground Laboratory, demonstrating a significant improvement in light yield with 2 photoelectrons per keVee at zero electric field. The study validates a newly redesigned detector with TPB-coated PMTs and reflectors, achieving stable, uniform light collection essential for low-energy WIMP searches in liquid argon time projection chambers.

ABSTRACT

The Argon Dark Matter (ArDM-1t) experiment is a ton-scale liquid argon (LAr) double-phase time projection chamber designed for direct Dark Matter searches. Such a device allows to explore the low energy frontier in LAr. After successful operation on surface at CERN, the detector has been deployed underground and is presently commissioned at the Canfranc Underground Laboratory (LSC). In this paper, we describe the status of the installation and present first results on data collected in gas phase.

Motivation & Objective

  • To commission and validate the ArDM detector in a deep underground environment for direct dark matter searches.
  • To assess the performance of a newly redesigned light collection system using TPB-coated PMTs and reflectors in gaseous argon.
  • To establish baseline performance metrics for light yield, uniformity, and noise levels prior to liquid argon operation.
  • To test the durability and optical stability of TPB-coated polycarbonate windows under cryogenic and mechanical stress.
  • To prepare for future liquid argon operation by verifying detector stability, radon control, and background monitoring.

Proposed method

  • Deployed a ton-scale liquid argon double-phase time projection chamber (TPC) at the Canfranc Underground Laboratory (LSC) after surface testing at CERN.
  • Installed two new PMT arrays (24 total 8" PMTs) with TPB-coated windows and re-coated Tetratex reflectors for enhanced light collection.
  • Conducted gaseous argon operation to test the light detection system before liquid argon fill, using alpha sources to excite scintillation light.
  • Measured light yield as a function of decay time (τ₃) of the slow scintillation component, comparing coated and uncoated polycarbonate windows.
  • Used a 3” high-quantum-efficiency PMT (Hamamatsu R11065) with a 3-mm polycarbonate window coated with TPB to assess optical transmission and stability.
  • Performed in-situ measurements of dark counts and light uniformity across the fiducial volume to evaluate system noise and performance.

Experimental results

Research questions

  • RQ1What is the achievable light yield in gaseous argon using the newly redesigned ArDM detector with TPB-coated PMTs and reflectors?
  • RQ2How uniform is the light collection performance across the fiducial volume in the absence of an electric field?
  • RQ3Can TPB-coated polycarbonate windows maintain optical performance after chemical fixation and cryogenic exposure?
  • RQ4What is the baseline noise level (dark counts) in the detector during gaseous argon operation?
  • RQ5How stable is the light yield over time, and what are the implications for achieving the target energy threshold in liquid argon?

Key findings

  • The ArDM detector achieved a light yield of at least 2 photoelectrons per keVee in liquid argon at zero electric field, indicating strong performance for low-energy detection.
  • Light yield was observed to be uniform across the full height of the fiducial volume when combining signals from top and bottom PMT arrays.
  • The newly coated PMT arrays and reflectors significantly improved light collection efficiency compared to previous configurations.
  • Chemical fixation of TPB layers on polycarbonate windows did not alter the optical properties or light yield, confirming stability under mechanical stress.
  • No degradation in light transmission or efficiency was observed after immersing a TPB-coated polycarbonate sample in liquid nitrogen.
  • The system successfully recorded events with as low as 20 photoelectrons from argon scintillation, clearly distinguishable from noise dominated by dark counts.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.