Skip to main content
QUICK REVIEW

[Paper Review] Sterile neutrino search at the ILL nuclear reactor: the STEREO experiment

V. Hélaine|arXiv (Cornell University)|Apr 29, 2016
Neutrino Physics ResearchPhysics and Astronomy15 citations
TL;DR

The STEREO experiment searches for sterile neutrinos by measuring energy spectrum distortions of reactor electron antineutrinos at a 10 m baseline from the ILL reactor. Using a segmented, Gd-loaded liquid scintillator detector with 6 cells and active/passive shielding, it achieves 1.5 signal-to-background ratio, enabling 95% C.L. sensitivity to the reactor antineutrino anomaly within 2 years of data-taking.

ABSTRACT

Search for a light sterile neutrino is currently a hot topic of neutrino physics, arising from the so-called gallium and reactor anomalies, in which a deficit of neutrinos was observed with respect to expectations. Such anomalies could be explained by short distance oscillations towards a sterile state, with $Δ\mathrm{m}^2\sim$1\,eV$^2$. The STEREO detector has been designed to track the electron anti-neutrino energy spectrum distortion from 3 to 8\,MeV due to such a new $L/E$ oscillation, and should therefore confirm or reject the light sterile neutrino hypothesis. Electron anti-neutrinos produced by the compact reactor core of the Institut Laue-Langevin (ILL) will be detected in a 6-cells segmented volume of Gd-loaded liquid scintillator through the inverse $β$-decay process. The STEREO detector is being set-up and will be commissioned in fall 2016, and start data taking soon after. In this paper we will present the final design of the detector and its status, as well as its expected sensitivity.

Motivation & Objective

  • Address the reactor antineutrino anomaly, a 7% deficit in detected flux compared to 3-neutrino predictions.
  • Test the hypothesis that short-baseline oscillations into a sterile neutrino state with Δm² ~ 2.3 eV² could explain the anomaly.
  • Achieve high-precision measurement of the antineutrino energy spectrum without relying on flux normalization.
  • Probe the parameter space allowed by the reactor anomaly with 95% confidence level sensitivity within 2 years.
  • Minimize systematic uncertainties through segmented detector design and comprehensive background suppression.

Proposed method

  • Use inverse beta decay (IBD) to detect electron antineutrinos: $\overline{\nu}_e + p \rightarrow e^+ + n$.
  • Segment the 2 m³ detector into 6 identical cells (40 cm thick) to measure relative spectral distortions over 2 m baselines.
  • Employ Gd-loaded liquid scintillator to tag neutron capture via 8 MeV gamma cascade, enabling delayed coincidence detection.
  • Implement a 40 cm thick outer crown of unloaded scintillator to improve energy resolution and neutron detection efficiency.
  • Apply active and passive shielding (B₄C, lead, borated polyethylene, and muon veto) to suppress cosmic and reactor-induced backgrounds.
  • Use a water-Cherenkov muon veto and pulse shape discrimination to reject correlated muon-induced backgrounds with 99.5% efficiency.

Experimental results

Research questions

  • RQ1Can the reactor antineutrino anomaly be explained by short-baseline oscillations into a sterile neutrino state with Δm² ~ 2.3 eV²?
  • RQ2Does the measured electron antineutrino energy spectrum show energy-dependent distortions consistent with active-to-sterile oscillations?
  • RQ3Can the STEREO detector achieve sufficient energy resolution and background suppression to exclude or confirm the sterile neutrino hypothesis?
  • RQ4What is the sensitivity of the segmented detector design to spectral distortions at 10 m baseline?
  • RQ5How well can the detector maintain stability and calibration over long-term operation with 2% energy scale uncertainty?

Key findings

  • The STEREO detector is designed to achieve 12% energy resolution for 2 MeV positrons, ensuring precise spectral measurement.
  • Neutron detection efficiency is expected at 60% with a 5 MeV gamma threshold, critical for IBD event identification.
  • The detector's stability is expected to be monitored at the 1% level between calibrations, ensuring long-term consistency.
  • Energy scale calibration is achievable with 2% uncertainty using an automated radioactive source circulation system.
  • The combined active and passive shielding reduces background to a signal-to-background ratio of 1.5, meeting the required threshold.
  • With 400 detected antineutrinos per day over 300 days, STEREO will probe the reactor anomaly parameter space at 95% C.L. within 2 years.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.