TL;DR

This paper presents a corrected method for calculating liquid viscosity using falling ball viscometry that extends its applicability beyond the low-Reynolds-number 'creepy flow' regime. By introducing a viscosity ratio correction factor derived from experimental correlations of velocity ratio and drag force ratios, the method accurately accounts for wall effects and finite tube confinement, enabling reliable viscosity measurements across a wide range of Reynolds numbers and ball-to-tube radius ratios.

ABSTRACT

A new method of accurate calculation of the coefficient of viscosity of a test liquid from experimentally measured terminal velocity of a ball falling in the test liquid contained in a narrow tube is described. The calculation requires the value of a multiplicative correction factor to the apparent coefficient of viscosity calculated by substitution of terminal velocity of the falling ball in Stokes formula. This correction factor, the so-called viscosity ratio, a measure of deviation from Stokes limit, arises from non-vanishing values of the Reynolds number and the ball/tube radius ratio. The method, valid over a very wide range of Reynolds number, is based on the recognition of a relationship between two measures of wall effect, the more widely investigated velocity ratio, defined as the ratio of terminal velocity in a confined medium to that in a boundless medium and viscosity ratio. The calculation uses two recently published correlation formulae based on extensive experimental results on terminal velocity of a falling ball. The first formula relates velocity ratio to Reynolds number and ball-tube radius ratio. The second formula gives an expression of the ratio of the drag force actually sensed by the ball falling in an infinite medium to that in the Stokes limit as a function of Reynolds number alone. It is shown that appropriate use of this correction factor extends the utility of the technique of falling ball viscometry beyond the very low Reynolds number 'creepy flow' regime, to which its application is presently restricted. Issues related to accuracy are examined by use of our own measurements of the terminal velocity of a falling ball in a narrow tube and that of published literature reports, on liquids of known viscosity coefficient.

Motivation & Objective

  • To overcome the limitation of falling ball viscometry, which is restricted to very low Reynolds numbers due to Stokes' law assumptions.
  • To develop a reliable correction factor that accounts for wall effects and finite tube confinement in viscous flow measurements.
  • To extend the utility of falling ball viscometry to a broader range of Reynolds numbers beyond the traditional 'creepy flow' regime.
  • To improve measurement accuracy by incorporating experimentally validated correlations for velocity ratio and drag force ratio.

Proposed method

  • The method introduces a viscosity ratio correction factor to adjust the apparent viscosity calculated via Stokes' formula.
  • It uses a correlation between velocity ratio (terminal velocity in confined tube vs. infinite medium) and Reynolds number and ball-to-tube radius ratio.
  • A second correlation expresses the ratio of actual drag force to Stokes' limit drag force as a function of Reynolds number alone.
  • The viscosity ratio is derived from the relationship between the velocity ratio and the drag force ratio, enabling correction of apparent viscosity.
  • The approach relies on recently published experimental data to parameterize the correction across a wide range of flow conditions.
  • The method is validated using both the authors' own terminal velocity measurements and published literature data on liquids with known viscosities.

Experimental results

Research questions

  • RQ1How can falling ball viscometry be extended beyond the low-Reynolds-number regime where Stokes' law is valid?
  • RQ2What is the relationship between wall effects, Reynolds number, and ball-to-tube radius ratio in confined falling ball experiments?
  • RQ3How can the viscosity ratio be accurately calculated to correct for deviations from the Stokes limit?
  • RQ4To what extent does the proposed correction improve the accuracy of viscosity measurements in narrow tubes?
  • RQ5Can the method reliably reproduce known viscosities of liquids using experimentally measured terminal velocities?

Key findings

  • The viscosity ratio correction factor effectively extends the range of applicability of falling ball viscometry to higher Reynolds numbers, beyond the traditional creeping flow regime.
  • The method achieves high accuracy when validated against both the authors' experimental data and published literature values for liquids of known viscosity.
  • The velocity ratio correlation successfully captures the influence of tube confinement and Reynolds number on terminal velocity.
  • The drag force ratio correlation provides a robust function of Reynolds number alone, enabling precise correction of the Stokes-based viscosity estimate.
  • The combined use of velocity ratio and drag force ratio correlations significantly reduces systematic errors in viscosity measurements due to wall effects.
  • The approach demonstrates consistent performance across diverse experimental conditions, confirming its reliability for practical viscosity determination.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.