[Paper Review] Study of using Quantum Computer to Solve Poisson Equation in Gate Insulators
This paper investigates the application of quantum computing (QC) to solve the Poisson equation in semiconductor gate insulators using the HHL algorithm. It demonstrates that while QC simulation achieves high accuracy comparable to TCAD, real quantum hardware yields significantly reduced fidelity due to noise, highlighting the urgent need for robust quantum circuits and error correction in practical quantum simulations of semiconductor device physics.
In this paper, the application of quantum computing (QC) in solving gate insulator Poisson equation is studied, through QC simulator and hardware in IBM. Various gate insulator stacks with and without fixed charges are studied. It is found that by increasing the number of clock bits and by choosing appropriate evolution time, accurate solutions can be obtained in QC simulation. However, when the real quantum hardware is used, the accuracy is substantially reduced. Therefore, a more robust quantum circuit or error correction should be employed and developed.
Motivation & Objective
- To explore the feasibility of using quantum computing to solve the Poisson equation in gate dielectric stacks in semiconductor devices.
- To assess the accuracy and reliability of quantum computing simulations versus real quantum hardware for solving linear systems arising in semiconductor TCAD.
- To evaluate the impact of key quantum circuit parameters—such as evolution time (t) and number of clock qubits (nl)—on solution fidelity and error.
- To compare quantum computing results with classical TCAD simulations (Sentaurus) for validation.
- To identify the limitations of current noisy intermediate-scale quantum (NISQ) hardware in solving practical semiconductor device problems.
Proposed method
- The HHL algorithm is implemented to solve discretized Poisson equations in 1D gate insulator stacks, mapping the system of linear equations 𝐴𝑥⃗=𝑏⃗⃗ to a quantum state preparation and unitary evolution process.
- The quantum circuit includes state preparation, quantum phase estimation (QPE) with controlled-U operations, ancilla qubit rotation based on eigenvalues, inverse QPE, and measurement.
- The number of clock qubits (nl) is varied to improve eigenvalue resolution, and evolution time (t) is tuned to ensure 𝜆𝑖̃=𝜆𝑖 for exact solutions.
- Two equivalent quantum circuits are designed and simulated using Qiskit’s qasm_simulator and statevector_simulator to validate consistency and accuracy.
- The same circuits are executed on IBM’s 5-qubit quantum processors (ibmq_5_yorktown, ibmq_belem, ibmq_santiago) to evaluate real hardware performance.
- Solution accuracy is evaluated using fidelity and relative absolute error, with results compared against TCAD Sentaurus simulations.
Experimental results
Research questions
- RQ1Can the HHL algorithm accurately solve the Poisson equation in gate insulator stacks using quantum simulation and real quantum hardware?
- RQ2How do the number of clock qubits (nl) and evolution time (t) affect the accuracy of quantum solutions in solving linear systems from semiconductor physics?
- RQ3Why does the performance of quantum hardware significantly degrade compared to simulation, and what factors contribute to this discrepancy?
- RQ4Is quantum fidelity a reliable metric for assessing the accuracy of quantum solutions in practical semiconductor device simulations?
- RQ5To what extent can current NISQ-era quantum hardware produce solutions comparable to classical TCAD tools for Poisson equation problems?
Key findings
- In quantum simulation, the HHL algorithm achieves a measurement probability ratio of 1:8.97 for |0⟩ to |1⟩ in the output qubit, closely matching the theoretical 1:9 ratio expected from the exact solution.
- The same circuit implemented on IBM’s ibmq_5_yorktown hardware yields a probability ratio of 1:1.41, indicating a substantial deviation from the expected solution due to noise.
- Increasing the number of clock qubits (nl) reduces error and widens the acceptable range of evolution time (t), improving solution accuracy in simulation.
- Despite achieving near-100% state fidelity in simulation, the average relative absolute error remains high (up to 16%) for some structures, indicating that fidelity is not a reliable indicator of solution accuracy.
- For larger systems like the 8×8 matrix in structure (c3), the eigenvalues cannot be encoded exactly with 6 clock qubits, leading to residual error even in simulation.
- Hardware results vary significantly across different days and devices, underscoring the instability and noise sensitivity of current NISQ hardware for scientific computing tasks.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.