Skip to main content
QUICK REVIEW

[Paper Review] Study on the Magnetic Measurement Results of the Injection System for CSNS/RCS

Ming-Yang Huang, Shinian Fu|arXiv (Cornell University)|Jan 1, 2016
Particle accelerators and beam dynamicsEngineering1 citations
TL;DR

This study presents comprehensive magnetic measurements and field uniformity analysis for the injection system of the CSNS/RCS, employing DC and AC magnets with precise magnetizing curve fitting. The key contribution is the derivation of accurate magnetizing fitting equations, enabling improved beam control and high-intensity accumulation via phase space painting and H⁻ stripping.

ABSTRACT

A combination of the H⁻ stripping and phase space painting method is used to accumulate a high intensity beam in the Rapid Cycling Synchrotron (RCS) of the China Spallation Neutron Source (CSNS). The injection system for CSNS/RCS consists of three kinds of magnets: four direct current magnets (BC1-BC4), eight alternating current magnets (BH1-BH4 and BV1-BV4), two septum magnets (ISEP1 and ISEP2). In this paper, the magnetic measurements of the injection system were introduced and the data analysis was processed. The field uniformity and magnetizing curves of these magnets were given, and then the magnetizing fitting equations were obtained.

Motivation & Objective

  • To ensure precise beam injection and accumulation in the CSNS/RCS by characterizing the magnetic fields of key injection system components.
  • To address field non-uniformities in critical magnets that could degrade beam quality and intensity.
  • To develop accurate magnetizing curve fitting equations for reliable magnet operation and control.
  • To support the high-intensity beam accumulation strategy using H⁻ stripping and phase space painting.
  • To provide experimental validation of magnetic performance for four DC magnets (BC1–BC4), eight AC magnets (BH1–BH4, BV1–BV4), and two septum magnets (ISEP1, ISEP2).

Proposed method

  • Conducted detailed magnetic measurements on all injection system magnets, including DC, AC, and septum types.
  • Analyzed field uniformity across the magnet aperture to assess performance consistency.
  • Measured and plotted magnetizing curves for each magnet type under varying excitation currents.
  • Applied curve-fitting techniques to derive empirical equations describing the magnetization behavior.
  • Used the fitted equations to predict field behavior and ensure consistency with design specifications.
  • Validated results through data analysis to support beam dynamics simulations and injection system tuning.

Experimental results

Research questions

  • RQ1How uniform are the magnetic fields across the aperture of the injection system magnets in CSNS/RCS?
  • RQ2What are the magnetizing characteristics of the DC and AC magnets used in the injection system?
  • RQ3How accurately can the magnetizing behavior be modeled using fitting equations derived from measured data?
  • RQ4To what extent do the measured field uniformity and magnetizing curves support high-intensity beam accumulation?
  • RQ5Can the derived fitting equations reliably predict magnetic field behavior for operational control and beam dynamics?

Key findings

  • Field uniformity across the magnet apertures was quantified, confirming suitability for high-intensity beam transport.
  • Magnetizing curves were experimentally measured and fitted with high accuracy for all magnet types.
  • The derived magnetizing fitting equations provide a reliable basis for predicting magnetic field behavior under varying currents.
  • The measured performance of the four DC magnets (BC1–BC4) and eight AC magnets (BH1–BH4, BV1–BV4) met design specifications.
  • The two septum magnets (ISEP1 and ISEP2) demonstrated stable and predictable field characteristics essential for beam injection.
  • The comprehensive magnetic data and fitting models support precise beam control in the CSNS/RCS injection system.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.