This study presents the first submillimetre interferometric imaging of 15 COSMOS/AzTEC submillimetre galaxies using the IRAM Plateau de Bure Interferometer at 1.3 mm, achieving 1.8 arcsecond resolution. It identifies multiwavelength counterparts, measures redshifts via photometric and radio-to-submm spectral index analysis, and finds a median redshift of z̃ = 3.17 ± 0.27 for the combined sample of 30 sources, with no significant trend between redshift and flux density.
We used the PdBI to map a sample of 15 SMGs in the COSMOS field at the wavelength of 1.3 mm. The target SMGs were originally discovered in the JCMT/AzTEC 1.1 mm continuum survey at S/N=4-4.5. This paper presents, for the first time, interferometric millimetre-wavelength observations of these sources. The angular resolution of our observations, 1.8", allowed us to accurately determine the positions of the target SMGs. Using a detection threshold of S/N>4.5 regardless of multiwavelength counterpart association, and 4
Motivation & Objective
- To conduct high-resolution (sub)millimetre interferometric imaging of a sample of 15 submillimetre galaxies (SMGs) detected in the AzTEC 1.1 mm survey within the COSMOS field.
- To improve positional accuracy and resolve source morphology by achieving 1.8 arcsecond angular resolution using the Plateau de Bure Interferometer.
- To identify multiwavelength counterparts for SMGs using optical to near-infrared photometry and spectroscopic redshifts.
- To determine the redshift distribution of the SMG sample using photometric redshifts and the Carilli-Yun radio-to-submm spectral index indicator.
- To assess the multiplicity fraction and test for correlations between redshift and submillimetre flux density in flux-limited SMG samples.
Proposed method
- Conducted 1.3 mm interferometric observations with the IRAM Plateau de Bure Interferometer (PdBI) on 15 AzTEC-detected SMGs in the COSMOS field.
- Achieved an angular resolution of ~1.8 arcseconds, enabling accurate source localization and morphological analysis.
- Used a detection threshold of S/N > 4.5 at 1.3 mm, with a relaxed threshold of 4 < S/N ≤ 4.5 if a multiwavelength counterpart is within 1.5 arcseconds.
- Combined PdBI data with multiwavelength data from optical to near-infrared surveys (e.g., UltraVISTA, Spitzer, HST) for counterpart identification.
- Estimated redshifts using photometric redshifts from multiwavelength SED fitting and the Carilli-Yun radio-to-submm spectral index method.
- Combined the current sample with the 15 brightest AzTEC SMGs (AzTEC1–15) to form a complete, flux- and S/N-limited 1.1 mm sample of 30 sources for statistical analysis.
Experimental results
Research questions
- RQ1What is the true redshift distribution of the 15 COSMOS/AzTEC SMGs observed with PdBI, and how do photometric and radio-to-submm spectral index redshifts compare?
- RQ2Are the SMGs in this sample resolved at 1.8 arcsecond resolution, and what fraction exhibit multiple components or complex morphologies?
- RQ3Is there a significant correlation between submillimetre flux density and redshift in this flux-limited sample of SMGs?
- RQ4What is the multiplicity fraction of SMGs in a complete, flux- and S/N-limited 1.1 mm sample, and how does it compare to previous estimates?
- RQ5How do the redshifts of the fainter SMGs (AzTEC16–30) compare to those of the brighter ones (AzTEC1–15), and do they follow the same distribution?
Key findings
- The PdBI survey detected 22 sources at 1.3 mm with S/N > 4.5, including 3 marginally resolved SMGs (AzTEC21, 27, 28) with elongated or clumpy morphologies.
- The median redshift of the 15 COSMOS SMGs (AzTEC16–30) is z̃ = 3.20 ± 0.25, derived from photometric and radio-to-submm spectral index redshifts.
- The combined sample of 30 SMGs (AzTEC1–30) has a median redshift of z̃ = 3.17 ± 0.27, consistent with previous mm-selected SMG samples.
- The mean redshifts of the brighter (AzTEC1–15) and fainter (AzTEC16–30) subgroups are statistically indistinguishable (⟨z⟩ = 3.16 ± 0.37 and 3.02 ± 0.20, respectively), with no significant trend between redshift and flux density.
- The K-S test indicates that the redshift distributions of the two subgroups are likely drawn from the same parent population, though the highest redshift sources (z > 4.3) are found among the strongest emitters.
- The multiplicity fraction among the 30 SMGs is estimated at ~25% ± 9%, based on resolved structures and confirmed multiple components in three sources.