[Paper Review] Subject Selection on a Riemannian Manifold for Unsupervised Cross-subject Seizure Detection
This paper proposes a novel subject selection method for unsupervised cross-subject seizure detection using spectral clustering on a Riemannian manifold of covariance matrices derived from EEG signals. By grouping subjects based on Riemannian distance and training an SVM on tangent spaces of selected clusters, the method improves accuracy to 89.84% and specificity to 89.64%, reducing the false positive rate to 0.77/hour on the CHB-MIT database—surpassing prior state-of-the-art methods.
Inter-subject variability between individuals poses a challenge in inter-subject brain signal analysis problems. A new algorithm for subject-selection based on clustering covariance matrices on a Riemannian manifold is proposed. After unsupervised selection of the subsets of relevant subjects, data in a cluster is mapped to a tangent space at the mean point of covariance matrices in that cluster and an SVM classifier on labeled data from relevant subjects is trained. Experiment on an EEG seizure database shows that the proposed method increases the accuracy over state-of-the-art from 86.83% to 89.84% and specificity from 87.38% to 89.64% while reducing the false positive rate/hour from 0.8/hour to 0.77/hour.
Motivation & Objective
- To address inter-subject variability in EEG-based seizure detection, which hinders the development of generalizable cross-subject models.
- To improve classification performance in unsupervised cross-subject learning by identifying subsets of subjects most similar to a test subject.
- To develop a subject selection framework that leverages the geometric structure of EEG covariance matrices on a Riemannian manifold.
- To reduce false positive rates while maintaining high sensitivity and specificity in seizure detection across diverse subjects.
Proposed method
- Covariance matrices are computed from EEG signals using the Sample Covariance Matrix (SCM) estimator, forming symmetric positive definite (SPD) matrices on a Riemannian manifold.
- Riemannian distance is computed using the log-Euclidean metric, defined as the Frobenius norm of the matrix logarithm of the generalized eigenvalue transformation.
- Each subject’s covariance matrices are transformed via affine-invariant normalization using the subject-specific geometric mean to enhance inter-subject comparability.
- Spectral clustering is applied on the Riemannian distance matrix to group subjects into clusters based on similarity of their EEG covariance structures.
- The geometric mean of each cluster is computed as the Riemannian center, and all data in the cluster are mapped to the tangent space at this mean.
- An SVM classifier is trained on the tangent-space representations of selected subjects and evaluated via leave-one-subject-out cross-validation on the CHB-MIT database.
Experimental results
Research questions
- RQ1Can spectral clustering on a Riemannian manifold of EEG covariance matrices effectively identify subject subsets most similar to a test subject in cross-subject seizure detection?
- RQ2How does subject selection based on Riemannian geometry improve classification performance compared to using all training subjects?
- RQ3To what extent can Riemannian manifold-based subject selection reduce false positive rates in unsupervised seizure detection?
- RQ4Does clustering subjects by their intrinsic covariance structure lead to better generalization than conventional cross-subject learning approaches?
- RQ5Can the proposed method achieve higher accuracy and specificity than state-of-the-art methods without requiring subject-specific fine-tuning?
Key findings
- The proposed method achieves a mean accuracy of 89.84% on the CHB-MIT database, representing a 3.01% improvement over the prior state-of-the-art (86.83%).
- Specificity increases from 87.38% to 89.64%, indicating better true negative classification.
- The false positive rate is reduced to 0.77 seizures per hour, down from 0.8/hour in prior work and significantly lower than the 1.7/hour reported in Shoeb’s original study.
- The method maintains high sensitivity, with a mean of 85.77% across all subjects, and achieves a mean latency of 5.24 seconds.
- Subject-specific performance varies, with individual accuracies ranging from 82.79% to 95.41%, demonstrating robustness across diverse patient profiles.
- The approach is the first to explicitly apply subject selection via Riemannian manifold clustering for unsupervised cross-subject seizure detection.