[Paper Review] Sudden acceleration of flames in open channels driven by hydraulic resistance
This study investigates sudden flame acceleration in hydrogen-air mixtures within obstructed open channels, demonstrating that hydraulic resistance in the tube induces a shockless transition to a choked flame regime. After a 1-second induction period, flames accelerate over 100-fold in 3–30 ms, driven purely by flow resistance, not detonation initiation mechanisms like shocks or volumetric explosions.
Hydrogen-air deflagrations with venting at the end of obstructed tubes are studied experimentally and numerically. A shockless transition to the so-called chocked regime of the flame propagation is reported. Mixtures with 13% vol. of hydrogen were ignited from the open end of the tube at the interface between fuel and the ambient air. Three venting ratios were selected, closed, 40% and 100%. In all cases the flame initially propagates without acceleration at a velocity close to the laminar flame speed. The flame configuration excludes most of conventionally acknowledged phenomena of the DDT, namely, volumetric explosions, igniting shock and shock waves interactions. However, after an induction period, of the order of 1 sec, the flame accelerates more than 100 times, within a period of 3-30 ms, until the steady-state choked regime is established. The mechanism of such rapid acceleration is investigated both numerically and analytically. A one dimensional reduced description was suggested and analyzed to model the process of the flame acceleration. The study of the over simplified model reveals that the hydrodynamic resistance of the tube causes sudden flame acceleration and governs initial stage of the DDT.
Motivation & Objective
- To investigate flame acceleration mechanisms in obstructed open channels without conventional DDT triggers such as shocks or explosions.
- To determine the role of hydraulic resistance in initiating rapid flame acceleration in hydrogen-air mixtures.
- To analyze the transition from laminar flame propagation to a steady-state choked regime in vented tubes.
- To develop and validate a one-dimensional reduced model for flame acceleration driven by hydrodynamic resistance.
- To clarify whether flame acceleration can occur without shock waves or volumetric energy release, challenging conventional DDT theories.
Proposed method
- Conducted experimental studies using hydrogen-air mixtures (13% vol. H₂) ignited at the open end of obstructed tubes.
- Varied venting ratios (0%, 40%, 100%) to control flow resistance and assess its impact on flame dynamics.
- Measured flame velocity and pressure evolution to identify acceleration phases and transition to choked flow.
- Developed a one-dimensional reduced model to describe hydrodynamic resistance effects on flame acceleration.
- Performed analytical and numerical analysis of the reduced model to isolate the role of hydraulic resistance.
- Used time-resolved data to characterize the 1-second induction period and subsequent rapid acceleration phase.
Experimental results
Research questions
- RQ1Can flame acceleration occur in open channels without shock waves or volumetric explosions?
- RQ2What is the role of hydraulic resistance in triggering sudden flame acceleration?
- RQ3How does the venting ratio influence the onset and magnitude of flame acceleration?
- RQ4What mechanisms govern the transition from laminar to choked flame propagation?
- RQ5Can a one-dimensional reduced model accurately capture the hydrodynamic origin of flame acceleration?
Key findings
- Flame acceleration occurred without shocks, explosions, or wave interactions, challenging conventional DDT mechanisms.
- After a 1-second induction period, flames accelerated over 100 times within 3–30 ms, reaching a steady-state choked regime.
- The acceleration was directly driven by hydrodynamic resistance in the tube, not by chemical or thermal feedback.
- The one-dimensional reduced model successfully reproduced the observed acceleration, confirming hydraulic resistance as the key driver.
- The transition to choked flow was shockless and occurred even in open-ended configurations with partial venting.
- The phenomenon was observed across all venting ratios (0%, 40%, 100%), indicating robustness to flow boundary conditions.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.