[Paper Review] Sustained cost declines in solar PV and battery storage needed to eliminate coal generation in India
This study models least-cost hybrid solar PV and lithium-ion battery storage systems to replace coal generation in India’s Karnataka, Gujarat, and Tamil Nadu states. It finds that sustained 6% annual cost declines in solar PV and battery storage—along with low-cost capital and solar PV costs below $250/kW—are essential to phase out coal by 2040, with hybrid systems offering 40% cost savings when replacing 99% of coal hours rather than 100%.
Unabated coal power in India must be phased out by mid-century to achieve global climate targets under the Paris Agreement. Here we estimate the costs of hybrid power plants - lithium-ion battery storage with wind and solar PV - to replace coal generation. We design least cost mixes of these technologies to supply stylized baseload and load-following generation profiles in three Indian states - Karnataka, Gujarat, and Tamil Nadu. Our analysis shows that availability of low cost capital, solar PV capital costs of at least $250/kW, and battery storage capacity costs at least 50% cheaper than current levels will be required to phase out existing coal power plants. Phaseout by 2040 requires a 6% annual decline in the cost of hybrid systems over the next two decades. We find that replacing coal generation with hybrid systems 99% of the hours over multiple decades is roughly 40% cheaper than 100% replacement, indicating a key role for other low cost grid flexibility mechanisms to help hasten coal phaseout. Solar PV is more suited to pairing with short duration storage than wind power. Overall, our results describe the challenging technological and policy advances needed to achieve the temperature goals of the Paris Agreement.
Motivation & Objective
- To assess the cost-competitiveness of hybrid solar PV and battery storage systems in replacing coal generation across three Indian states.
- To identify the required cost trajectories for solar PV and battery storage to enable coal phaseout by 2040.
- To evaluate the role of grid flexibility mechanisms in reducing the cost of coal replacement.
- To compare the relative suitability of solar PV versus wind for pairing with short-duration battery storage in Indian contexts.
- To provide a policy-relevant benchmark for India’s power sector decarbonization under the Paris Agreement.
Proposed method
- Developed an optimization model to determine the least-cost mix of solar PV, wind, and 4-hour lithium-ion battery storage to meet stylized baseload and flexible coal generation profiles.
- Used 20 years of hourly wind and solar resource data for Karnataka, Gujarat, and Tamil Nadu to simulate generation output.
- Formulated a cost-minimization problem subject to energy balance, battery state-of-charge constraints, and round-trip efficiency (75%) and capacity limits.
- Set target generation profiles as 100 MW baseload (24/7) and flexible profiles that vary with renewable availability, based on real-state net load data for validation.
- Constrained battery charge and discharge to 25% of total capacity per hour to reflect realistic cycling limits.
- Conducted sensitivity analyses on battery lifetime, efficiency, and storage duration (4h, 6h, 8h, 10h), and used real coal plant data from the Vasudha Foundation database for validation.
Experimental results
Research questions
- RQ1What cost trajectory for solar PV and battery storage is required to make hybrid systems competitive with existing coal plants in India?
- RQ2How do levelized costs of hybrid systems compare when replacing 99% versus 100% of coal generation hours?
- RQ3Which renewable source—solar PV or wind—is more suitable for pairing with short-duration battery storage in Indian states?
- RQ4To what extent can grid flexibility mechanisms reduce the cost of coal phaseout?
- RQ5How do assumptions about capital cost of capital (WACC) and system lifetime affect the cost competitiveness of hybrid systems?
Key findings
- A 6% annual cost decline in both solar PV and battery storage is required to make hybrid systems cost-competitive with coal and enable coal phaseout by 2040.
- Hybrid systems replacing 99% of coal generation hours are roughly 40% cheaper than those replacing 100%, indicating a key role for grid flexibility mechanisms.
- Solar PV dominates hybrid systems due to higher predictability and lower cost compared to wind, making it more suitable for pairing with short-duration storage.
- With a 2.5% WACC, hybrid system LCOE ranges from $10–14/kWh, which is 3–4 times higher than current coal marginal costs (~$3.0/kWh).
- Current system costs are not competitive with coal without sustained cost declines; a 60% reduction in hybrid system costs is needed to match coal’s marginal cost.
- The stylized flexible coal profiles used in the model produce results consistent with real net load data from Karnataka, validating the model’s robustness.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.