Skip to main content
QUICK REVIEW

[Paper Review] Synthetic contrast enhancement in cardiac CT with Deep Learning

Gianmarco Santini, Lorena M. Zumbo|arXiv (Cornell University)|Jul 2, 2018
Advanced X-ray and CT ImagingEngineering5 references18 citations
TL;DR

This paper proposes a deep learning method to synthesize contrast-enhanced cardiac CT (CECT) images from non-contrast CT scans using a deconvolutional fully convolutional network. The model generates synthetic CECT images with high fidelity in attenuation dynamics and left cardiac chamber morphology, achieving a Dice score of 0.88±0.03 and volume error of 9.1±6.2%, outperforming human inter-observer variability and enabling non-contrast CT to extract hidden hemodynamic and volumetric cardiac information.

ABSTRACT

In Europe the 20% of the CT scans cover the thoracic region. The acquired images contain information about the cardiovascular system that often remains latent due to the lack of contrast in the cardiac area. On the other hand, the contrast enhanced computed tomography (CECT) represents an imaging technique that allows to easily assess the cardiac chambers volumes and the contrast dynamics. With this work we aim to face the problem of extraction and presentation of these latent information, using a deep learning approach with convolutional neural networks. Starting from the extraction of relevant features from the image without contrast medium, we try to re-map them on features typical of CECT, to synthesize an image characterized by an attenuation in the cardiac chambers as if a virtually iodine contrast medium was injected. The purposes are to guarantee an estimation of the left cardiac chambers volume and to perform an evaluation of the contrast dynamics. Our approach is based on a deconvolutional network trained on a set of 120 patients who underwent both CT acquisitions in the same contrastographic arterial phase and the same cardiac phase. To ensure a reliable predicted CECT image, in terms of values and morphology, a custom loss function is defined by combining an error function to find a pixel-wise correspondence, which takes into account the similarity in term of Hounsfield units between the input and output images and by a cross-entropy computed on the binarized versions of the synthesized and of the real CECT image. The proposed method is finally tested on 20 subjects.

Motivation & Objective

  • To extract latent cardiovascular information from non-contrast cardiac CT scans that remains undetected due to lack of contrast enhancement.
  • To develop a deep learning model capable of synthesizing contrast-enhanced CT images as if iodine contrast had been administered.
  • To enable accurate volumetric assessment of left atrium and left ventricle using only non-contrast CT scans.
  • To reduce inter-observer variability in cardiac chamber segmentation by replacing human-dependent visual memory with a reproducible, deep learning-based image synthesis system.
  • To provide a clinically viable method for estimating cardiac chamber volumes and contrast dynamics without additional radiation or contrast agent exposure.

Proposed method

  • A fully convolutional deconvolutional network is trained to map non-contrast CT images to synthetic CECT images, leveraging spatial and contrast-invariant feature extraction.
  • A custom loss function combines a pixel-wise L2 loss based on Hounsfield Unit (HU) similarity and a cross-entropy loss on binarized left heart chamber masks to preserve both attenuation values and anatomical morphology.
  • The network is trained on 120 patients with paired non-contrast and contrast-enhanced CT scans acquired at the same cardiac phase (75% R-R) and reconstructed with 3.0 mm slice thickness.
  • Data preprocessing includes rigid registration using mutual information to correct for respiratory motion, reslicing to a common 3.0 mm axial resolution, and cropping to only include slices containing the left atrium and ventricle.
  • Training uses data augmentation via random rotations (up to 25°) and is optimized with Adam (initial learning rate 10⁻⁴, batch size 32) for 800 epochs on a single NVIDIA TITAN X GPU.
  • The model is evaluated on 20 test subjects, with performance assessed using Dice coefficient, volume percentage error (dV%), normalized mutual information (NMI), and peak signal-to-noise ratio (PSNR).

Experimental results

Research questions

  • RQ1Can a deep learning model synthesize clinically useful CECT-like images from non-contrast cardiac CT scans with high anatomical and attenuation fidelity?
  • RQ2To what extent can the synthesized CECT images improve the accuracy and reproducibility of left cardiac chamber volume estimation compared to human readers?
  • RQ3Does the deep learning model preserve the contrast dynamics between cardiac chambers as seen in real CECT scans?
  • RQ4Can the model generalize across diverse heart shapes and slice positions without relying on patient-specific anatomical priors?
  • RQ5Is the synthetic image generation process robust enough to reduce inter-observer variability in cardiac chamber segmentation?

Key findings

  • The synthetic CECT images achieved a normalized mutual information (NMI) of 0.93±0.03 and a peak signal-to-noise ratio (PSNR) of 48.30±2.03 compared to real CECT, indicating high similarity in image content and attenuation dynamics.
  • The automated segmentation of left atrium and left ventricle on synthesized images achieved a Dice coefficient of 0.88±0.03, demonstrating strong overlap with manual ground truth.
  • The volume percentage error (dV%) between the synthesized and ground truth chambers was 9.1±6.2%, indicating high accuracy in volumetric estimation.
  • The model outperformed human readers in reproducibility, with an intra-observer correlation (ρ) of 0.99 and inter-observer correlation (ρ) of 0.85, showing reduced variability compared to human readers.
  • The Dice score for the deep learning model (0.89±0.03) was higher than that of human readers (0.85±0.05), indicating superior segmentation accuracy.
  • The method enables reliable extraction of left cardiac chamber volumes and contrast dynamics from non-contrast CT scans, offering a potential clinical tool for early detection of cardiopathies and valvular diseases.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.