This paper proposes an improved DualGAN framework for unpaired MRI-to-CT synthesis, integrating perceptual loss via VGG-16 and coordinate convolutional layers to enhance structural fidelity and image quality. The method achieves a mean absolute error (MAE) of 61 HU and SSIM of 0.8 on synthetic CTs, significantly improving realism and anatomical accuracy over baseline GANs.
Synthetic CT image generation from MRI scan is necessary to create radiotherapy plans without the need of co-registered MRI and CT scans. The chosen baseline adversarial model with cycle consistency permits unpaired image-to-image translation. Perceptual loss function term and coordinate convolutional layer were added to improve the quality of translated images. The proposed architecture was tested on paired MRI-CT dataset, where the synthetic CTs were compared to corresponding original CT images. The MAE between the synthetic CT images and the real CT scans is 61 HU computed inside of the true CTs body shape.
Motivation & Objective
- To develop a robust, unpaired MRI-to-CT image translation method for radiotherapy planning without requiring co-registered scans.
- To address misregistration artifacts caused by separate MRI and CT acquisition by generating synthetic CTs from MRI alone.
- To improve image quality and structural consistency in synthetic CTs using advanced deep learning components.
- To evaluate the impact of perceptual loss and coordinate convolutional layers on translation fidelity in medical image synthesis.
Proposed method
- Adopts an improved DualGAN architecture with two generators (MRI→CT and CT→MRI) and two discriminators to enforce cycle consistency without paired data.
- Introduces a perceptual loss function using pre-trained VGG-16 to match high-level features between real and generated CT images.
- Incorporates coordinate convolutional layers that encode spatial position (x, y) into feature maps to improve localization of anatomical structures.
- Trains the model end-to-end on unpaired MRI and CT volumes using adversarial loss, cycle consistency, and perceptual loss.
- Uses three datasets (CPTAC, head-and-neck cancer, private) with 7:3 train-test split, normalizing and preprocessing 3D axial slices.
- Evaluates performance using MAE, PSNR, and SSIM on the test set, comparing four configurations: DualGAN, DualGAN+CC, DualGAN+VGG, and DualGAN+VGG+CC.
Experimental results
Research questions
- RQ1Can perceptual loss from a pre-trained VGG-16 network improve the perceptual quality of synthetic CTs generated from MRI?
- RQ2Does the integration of coordinate convolutional layers enhance spatial accuracy and structural detail in MRI-to-CT translation?
- RQ3How does the combination of perceptual loss and coordinate convolutional layers compare to baseline DualGAN in terms of quantitative and qualitative performance?
- RQ4To what extent does the model preserve anatomical structures such as bone and air in complex regions like the nose and teeth?
- RQ5Can the proposed method achieve clinically acceptable image quality for radiotherapy planning without paired MRI-CT scans?
Key findings
- The DualGAN with both perceptual loss and coordinate convolutional layers (DualGAN, VGG, CC) achieved the lowest MAE of 60.83 ± 2.20 HU, outperforming the baseline DualGAN (62.95 ± 1.17 HU).
- The combination of perceptual loss and coordinate convolution improved SSIM to 0.80 ± 0.03, compared to 0.79 ± 0.02 for the baseline, indicating better structural similarity.
- The model achieved a PSNR of 17.21 ± 1.00 dB with the full configuration, showing improved signal quality in synthetic CTs.
- Visual inspection confirmed that the perceptual loss and coordinate convolution enhanced image realism and reduced blurring, especially in soft tissue and bony structures.
- The highest error occurred in complex anatomical regions such as the nose and teeth, indicating limitations in fine-structure translation.
- The method successfully generated synthetic CTs with clinically relevant image quality, achieving an MAE of 61 HU within the true body contour, comparable to state-of-the-art methods.