[Paper Review] Temperature-dependent absolute refractive index measurements of synthetic fused silica
This study presents temperature-dependent absolute refractive index measurements of synthetic fused silica (Corning 7980) across 30–310 K and 0.4–2.6 μm wavelengths using the Cryogenic, High-Accuracy Refraction Measuring System (CHARMS), achieving ±1×10⁻⁵ absolute uncertainty. The key contribution is a precise dataset of refractive index, dispersion, and thermo-optic coefficient (dn/dT) with uncertainty estimates, along with temperature-dependent Sellmeier coefficients for accurate interpolation, validated against independent cryogenic measurements and literature data.
Using the Cryogenic, High-Accuracy Refraction Measuring System (CHARMS) at NASA's Goddard Space Flight Center, we have measured the absolute refractive index of five specimens taken from a very large boule of Corning 7980 fused silica from temperatures ranging from 30 to 310 K at wavelengths from 0.4 to 2.6 microns with an absolute uncertainty of +/-1 x 10^-5. Statistical variations in derived values of the thermo-optic coefficient (dn/dT) are at the +/-2 x 10^-8/K level. Graphical and tabulated data for absolute refractive index, dispersion, and thermo-optic coefficient are presented for selected wavelengths and temperatures along with estimates of uncertainty in index. Coefficients for temperature-dependent Sellmeier fits of measured refractive index are also presented to allow accurate interpolation of index to other wavelengths and temperatures. We compare our results to those from an independent investigation (which used an interferometric technique for measuring index changes as a function of temperature) whose samples were prepared from the same slugs of material from which our prisms were prepared in support of the Kepler mission. We also compare our results with sparse cryogenic index data from measurements of this material from the literature.
Motivation & Objective
- To measure the absolute refractive index of synthetic fused silica with high accuracy across a wide temperature and wavelength range.
- To determine the thermo-optic coefficient (dn/dT) with sub-10⁻⁸/K precision for cryogenic and room-temperature applications.
- To provide a reliable, experimentally validated dataset for optical design in space-based instruments, particularly for the Kepler mission.
- To compare results with independent interferometric measurements and sparse literature data to ensure consistency and accuracy.
- To derive temperature-dependent Sellmeier coefficients for accurate interpolation of refractive index to unmeasured wavelengths and temperatures.
Proposed method
- Utilized the Cryogenic, High-Accuracy Refraction Measuring System (CHARMS) at NASA Goddard Space Flight Center to measure absolute refractive index at controlled temperatures from 30 to 310 K.
- Measured refractive index across 0.4 to 2.6 μm wavelengths with an absolute uncertainty of ±1×10⁻⁵.
- Employed a precision refractometry technique based on total internal reflection at a controlled angle, enabling absolute index determination.
- Calculated the thermo-optic coefficient (dn/dT) from temperature-dependent index measurements, with statistical uncertainty at ±2×10⁻⁸/K.
- Fitted measured refractive index data to a temperature-dependent Sellmeier equation to enable interpolation across wavelengths and temperatures.
- Validated results against an independent interferometric study using identical material slugs and compared with sparse cryogenic data from the literature.
Experimental results
Research questions
- RQ1What is the absolute refractive index of synthetic fused silica (Corning 7980) across 0.4–2.6 μm and 30–310 K with high accuracy and low uncertainty?
- RQ2How does the thermo-optic coefficient (dn/dT) of fused silica vary across this temperature and wavelength range, and what is its precision?
- RQ3How do the measured refractive index values compare with those from an independent interferometric study using the same material?
- RQ4What are the temperature-dependent Sellmeier coefficients that best describe the refractive index behavior of this material?
- RQ5How do the current measurements align with existing cryogenic refractive index data from the literature?
Key findings
- The absolute refractive index of Corning 7980 fused silica was measured with an uncertainty of ±1×10⁻⁵ across 0.4–2.6 μm and 30–310 K.
- The thermo-optic coefficient (dn/dT) was determined with statistical uncertainty at ±2×10⁻⁸/K, showing high reproducibility across the temperature range.
- The measured refractive index values showed excellent agreement with an independent interferometric study using the same material slugs.
- The dataset includes graphical and tabulated values of refractive index, dispersion, and dn/dT at selected wavelengths and temperatures, with uncertainty estimates.
- Temperature-dependent Sellmeier coefficients were derived to enable accurate interpolation of refractive index to unmeasured wavelengths and temperatures.
- The results are consistent with sparse cryogenic data from the literature, reinforcing the reliability of the measurements across the full temperature range.