[Paper Review] TEMPUS, a Timepix4-based system for event-based X-rays detection
This paper presents TEMPUS, a Timepix4-based single-chip X-ray detector system designed for event-driven, nanosecond-resolution X-ray detection. It operates in both high-frame-rate photon-counting and precise time-stamping modes, achieving sub-10 ns time resolution in initial tests at PETRA III and ESRF, demonstrating its capability for ultrafast X-ray science applications such as nuclear resonance scattering and X-ray photon correlation spectroscopy.
A readout system based on the Timepix4 ASIC, is being developed for photon science. The TEMPUS detector can be operated in two distinct modes: a photon counting mode, which allows for conventional full-frame readout at rates up to 40 kfps; and an event-driven time-stamping mode, which allows excellent time resolution in the nanosecond regime in measurements with moderate X-ray flux. In this paper, we introduce the initial prototype, a single-chip system, and present the first results obtained at PETRA III and ESRF.
Motivation & Objective
- Develop a next-generation X-ray detector to replace legacy LAMBDA systems at synchrotron facilities.
- Enable event-based X-ray detection with nanosecond time resolution for ultrafast dynamics studies.
- Leverage the Timepix4 ASIC’s dual-mode operation (photon counting and time-stamping) to improve data efficiency and temporal resolution.
- Address the challenges of high-brilliance X-ray beams in 4th-generation light sources like PETRA IV.
- Support emerging techniques such as nuclear resonance scattering (NRS) and X-ray photon correlation spectroscopy (XPCS) on sub-microsecond timescales.
Proposed method
- Utilizes the Timepix4 ASIC, a 448×512 pixel, 55 µm-pitch sensor with 16 high-speed Gb/s data links for high-bandwidth readout.
- Operates in two modes: (1) conventional photon counting with frame rates up to 40 kfps, and (2) event-driven time-stamping with 200 ps binning for Time-of-Arrival (ToA) and Time-over-Threshold (ToT).
- Employs a single-chip design with a 300-µm thick hole-collecting silicon sensor to minimize dead areas and support large solid-angle coverage.
- Applies time-walk correction and energy discrimination to improve time resolution and reduce artifacts in ToA distributions.
- Uses external triggers and digital pixel inputs to timestamp external events relative to X-ray photon arrivals.
- Leverages high-speed data links (up to 5.12 Gb/s per link, total 80 Gb/s) for real-time data acquisition and processing.
Experimental results
Research questions
- RQ1Can the Timepix4 ASIC enable sub-10 ns time resolution in X-ray detection under moderate flux conditions?
- RQ2How does sensor thickness and charge collection time affect time resolution in event-based X-ray detection?
- RQ3To what extent can event-driven readout reduce data volume compared to full-frame photon counting in low-flux experiments?
- RQ4Can the TEMPUS system resolve individual electron bunches in modern synchrotron storage rings like PETRA III and ESRF?
- RQ5What are the limitations of current silicon sensor technology in achieving optimal time resolution, and how can they be mitigated?
Key findings
- The TEMPUS prototype achieved a time resolution of 23.3 ns (FWHM) for high-energy photons and 9.7 ns for low-energy photons at PETRA III, consistent with expected values.
- At ESRF, the system achieved 12.1 ns and 8.5 ns time resolution for 14.4 keV and 17.2 keV photons, respectively, with improved bias voltage and sensor quality.
- The ToA distributions clearly resolved the 40-bunch structure in PETRA III’s 7/8 + 1 filling mode and the single-bunch structure in the 7/8 + 1 mode.
- Time-walk correction and energy discrimination significantly reduced artifacts in ToA distributions, though residual effects from charge sharing and low-ToT events were observed.
- The system demonstrated stable high-speed data acquisition via 16 Gb/s links, with full utilization of the Timepix4’s 80 Gb/s theoretical bandwidth.
- Sensor limitations—particularly the 300-µm hole-collecting silicon sensor—were identified as the main factor limiting time resolution, suggesting that electron-collecting sensors or LGADs could improve performance.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.