[Paper Review] Test beam performance of a novel RICH detector with timing capabilities for the future ALICE~3 PID system at LHC
This paper reports beam-test results of a SiPM-based RICH prototype for ALICE 3, achieving 4.2 mrad single-photon angular resolution and ~46 ps relative time resolution between two timing arrays, with >99% charged-particle detection efficiency.
The ALICE Collaboration is proposing a completely new apparatus, ALICE 3, for the LHC Run 5 and beyond. A key subsystem for charged particle identification will be a Ring-Imaging Cherenkov (RICH) detector consisting of an aerogel radiator and a photosensitive surface based on Silicon Photomultiplier (SiPM) arrays in a proximity-focusing configuration. A thin high-refractive index slab of transparent material (window), acting as a second Cherenkov radiator, is glued on the entrance face of the SiPM arrays to achieve precise charged particle timing. Requiring time matching between aerogel Cherenkov photon and track hits leads to an improvement of pattern recognition by discarding the uncorrelated SiPM dark count hits. In this work we present the current status of the R\&D performed for the ALICE 3 RICH detector prototype and the expected full scale system performance. A special focus will be given to the beam test results obtained with a small-scale prototype instrumented with various array of Hamamatsu SiPMs with pitches ranging from 1 to 3 mm. The Cherenkov radiator consisted of a 2 cm thick aerogel tile with a refractive index of 1.03 at 400 nm wavelength. For timing measurements SiPM arrays coupled with two different window materials (SiO$_2$ and MgF$_2$) were used. The prototype was successfully tested in beam test campaigns at the CERN PS T10 beam line. The data were collected with a complete chain of front-end and readout electronics based on the Petiroc 2A and Radioroc 2 together with a picoTDC to measure charges and times. We measured a charged particle detection efficiency above 99\% and a single photon angular resolution better than 4.2 mrad at the Cherenkov angle saturation with a time resolution better than 70 ps for charged particles.
Motivation & Objective
- Motivate the ALICE 3 PID system need for precise charged-particle identification over wide momentum ranges.
- Develop and test a proximity-focusing RICH prototype with aerogel radiator and SiPM-based photon detection.
- Demonstrate timing capability to suppress uncorrelated background in RICH photon hits.
- Evaluate prototype performance against ALICE 3 bRICH specifications in beam tests.
Proposed method
- Prototype RICH built with a 2 cm aerogel radiator (n=1.03 at 400 nm) and SiPM-based photon detection arrays.
- In 2023–2024 beam tests at CERN PS T10, prototypes used SiPM arrays with 1–3 mm pitch and two window materials (SiO2 and MgF2) as secondary radiators.
- Readout via custom front-end electronics (Petiroc 2A in 2023; Radioroc 2 with picoTDC in 2024) to measure charge and arrival time.
- Timing measurements rely on two central SiPM arrays along the beam line to enable time-difference (ToA/ToT) based particle timing.
- Event selection uses time-matching between aerogel Cherenkov photons and track hits to suppress uncorrelated background.
- Geometric reconstruction assumes emission in the aerogel middle plane and back-propagates to compute Cherenkov angles (θ_ch).

Experimental results
Research questions
- RQ1Can a SiPM-based RICH in proximity-focusing configuration meet ALICE 3 bRICH angular resolution goals (≈1.5 mrad at saturation) using a 2 cm aerogel radiator?
- RQ2What are the achievable single-photon angular resolution and per-channel time resolution when adding a secondary radiator window for timing?
- RQ3How effectively can time-based hit selection suppress uncorrelated background in the RICH prototype?
- RQ4What are the overall charged-particle detection efficiency and timing performance in a beam environment at 10 GeV/c?
- RQ5How does the prototype performance compare to the ALICE 3 bRICH baseline specifications?
Key findings
- Single-photon angular resolution at Cherenkov angle saturation is 4.2 mrad with a 2 cm aerogel (n=1.03).
- Time matching between aerogel photons and track hits suppresses uncorrelated background hits.
- Time resolution for the relative timing between two arrays is about 46 ps (sigma) from a 112 ps FWHM distribution; corresponds to ~30 ps per single SiPM channel.
- Detected charged-particle efficiency exceeds 99%.
- Cherenkov angle for pions in the aerogel is reconstructed near 241.5 mrad, with a clear peak after background suppression.
- Variations in SiPM pitch (1–3 mm) and window radiators (SiO2, MgF2) influence angular and timing performance but remain consistent with ALICE 3 bRICH requirements.

Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.