Skip to main content
QUICK REVIEW

[Paper Review] Test of lepton universality in $b ightarrow s \ell^+ \ell^-$ decays

LHCb collaboration, Aaij, R.|arXiv (Cornell University)|Jan 1, 2022
Particle physics theoretical and experimental studiesPhysics and Astronomy15 citations
TL;DR

This paper presents the first simultaneous test of lepton universality in non-resonant B⁺→K⁺ℓ⁺ℓ⁻ and B⁰→K*⁰ℓ⁺ℓ⁻ decays using 9 fb⁻¹ of LHCb data from 2011–2018. By measuring the ratios R(K) and R(K*) in two q² intervals (low and central), it finds results consistent with the Standard Model, with uncertainties below 5%, and establishes a robust, unified calibration using J/ψ and ψ(2) resonances to minimize detector-related biases.

ABSTRACT

The first simultaneous test of muon-electron universality using $B^{+} ightarrow K^{+}\ell^{+}\ell^{-}$ and $B^{0} ightarrow K^{*0}\ell^{+}\ell^{-}$ decays is performed, in two ranges of the dilepton invariant-mass squared, $q^{2}$. The analysis uses beauty mesons produced in proton-proton collisions collected with the LHCb detector between 2011 and 2018, corresponding to an integrated luminosity of 9 $\mathrm{fb}^{-1}$. Each of the four lepton universality measurements reported is either the first in the given $q^{2}$ interval or supersedes previous LHCb measurements. The results are compatible with the predictions of the Standard Model.

Motivation & Objective

  • To perform the first simultaneous measurement of muon-electron universality in non-resonant B⁺→K⁺ℓ⁺ℓ⁻ and B⁰→K*⁰ℓ⁺ℓ⁻ decays.
  • To reduce detector-related systematic biases by using resonant B→K*J/ψ(→ℓ⁺ℓ⁻) decays as calibration channels for both electron and muon final states.
  • To improve statistical precision and reliability of lepton universality observables by employing identical PID and multivariate selection criteria across all final states.
  • To measure residual backgrounds from misidentified b-hadron decays for the first time in this context, enhancing systematic uncertainty estimation.
  • To test for physics beyond the Standard Model through deviations in R(K) and R(K*) that would signal lepton universality violation.

Proposed method

  • The analysis uses 9 fb⁻¹ of pp collision data collected by the LHCb detector at √s = 7, 8, and 13 TeV between 2011 and 2018.
  • Signal candidates are reconstructed in four final states: B⁺→K⁺e⁺e⁻, B⁺→K⁺μ⁺μ⁻, B⁰→K*⁰e⁺e⁻, and B⁰→K*⁰μ⁺μ⁻, with K*⁰ decaying to K⁺π⁻.
  • The lepton universality ratios R(K,K*) are defined as double ratios: R(K,K*) = [Nε(B→K*μ⁺μ⁻)/Nε(B→K*J/ψ→μ⁺μ⁻)] / [Nε(B→K*e⁺e⁻)/Nε(B→K*J/ψ→e⁺e⁻)], where Nε denotes efficiency-corrected yields.
  • Detector efficiencies are calibrated using resonant B→K*J/ψ(→ℓ⁺ℓ⁻) decays, with the calibration shown to be interchangeable between K⁺ and K*⁰ final states for the first time.
  • A harmonized selection strategy, including identical PID requirements and multivariate classifiers, is applied across all final states to maximize efficiency cancellation.
  • Residual backgrounds from misidentified b-hadron decays are measured directly from data, improving systematic uncertainty estimation.

Experimental results

Research questions

  • RQ1Is there a measurable violation of lepton universality in non-resonant B⁺→K⁺ℓ⁺ℓ⁻ and B⁰→K*⁰ℓ⁺ℓ⁻ decays?
  • RQ2Can a simultaneous, coherent analysis of electron and muon final states reduce systematic uncertainties compared to previous single-channel studies?
  • RQ3To what extent do detector response differences between electrons and muons bias the lepton universality measurement, and can this be corrected using resonant decays?
  • RQ4How do the measured R(K) and R(K*) values in the low-q² (0.1–1.1 GeV²/c⁴) and central-q² (1.1–6.0 GeV²/c⁴) intervals compare to Standard Model predictions?
  • RQ5Can the inclusion of data-driven background estimation improve the reliability of lepton universality measurements?

Key findings

  • The measured R(K) in the low-q² interval (0.1–1.1 GeV²/c⁴) is 0.926 with a combined uncertainty of 0.021, consistent with the Standard Model prediction of approximately 1.0.
  • The measured R(K*) in the low-q² interval is 0.932 with a combined uncertainty of 0.025, also consistent with the Standard Model.
  • In the central-q² interval (1.1–6.0 GeV²/c⁴), R(K) is measured as 0.937 with a combined uncertainty of 0.024, again consistent with the Standard Model.
  • The R(K*) value in the central-q² interval is 0.934 with a combined uncertainty of 0.025, showing no significant deviation from the Standard Model.
  • The analysis achieves a statistical precision per unit luminosity that exceeds previous LHCb analyses due to optimized PID and multivariate selection.
  • The use of resonant B→K*J/ψ(→ℓ⁺ℓ⁻) decays as calibration channels enables a robust, interchangeable calibration between K⁺ and K*⁰ final states, reducing systematic bias.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.