Skip to main content
QUICK REVIEW

[Paper Review] Tests of a High Resolution Time of Flight System Based on Long and Narrow Scintillator

E. Chen, M. Saulnier|ArXiv.org|Jun 16, 1996
Advanced Frequency and Time StandardsPhysics and Astronomy4 citations
TL;DR

This paper presents a high-resolution time-of-flight (TOF) system using long, narrow scintillator blocks (2.5×2.5×200 cm) coupled with photomultipliers to achieve sub-100 ps timing resolution. Using Amperex XP2020/UR and Hamamatsu R2021 photomultipliers, the system achieved 71 ps and 81 ps timing resolution, respectively, with bulk scintillator outperforming scintillating fiber blocks due to superior internal reflectivity.

ABSTRACT

We have tested a prototype time-of-flight system based on bulk scintillator block of dimensions $2.5 imes 2.5 imes 200$ cm. Using a calibration scheme similar to the one used in actual collider experiments, we have achieved a resolution of 71 ps using Amperex XP2020/UR photomultipliers and 81 ps using proximity-focusing fine-mesh photomultipliers (Hamamatsu R2021). Results are also obtained for scintillating fiber blocks of the same dimensions. Good internal reflectivity of the bulk scintillator block resulted in resolutions superior to the fibre blocks. A single-photon pulsed laser system was used to study photomultipliers and the results were used in a Monte Carlo simulation of the system to study the critical elements that determine the resolution.

Motivation & Objective

  • To develop and test a high-resolution time-of-flight system for particle physics applications.
  • To evaluate the timing performance of bulk scintillator blocks versus scintillating fiber blocks in a long, narrow geometry.
  • To compare the timing resolution achieved with two types of photomultipliers: standard (Amperex XP2020/UR) and proximity-focusing fine-mesh (Hamamatsu R2021).
  • To identify critical system components affecting timing resolution through laser calibration and Monte Carlo simulation.
  • To validate the system's performance using a single-photon pulsed laser for precise photomultiplier characterization.

Proposed method

  • A prototype time-of-flight system was constructed using bulk scintillator blocks of dimensions 2.5×2.5×200 cm.
  • Photomultipliers (Amperex XP2020/UR and Hamamatsu R2021) were coupled to the ends of the scintillator blocks to detect scintillation light.
  • A single-photon pulsed laser system was used to calibrate and characterize the photomultiplier response and time resolution.
  • Timing resolution was measured using a calibration scheme analogous to that used in actual collider experiments.
  • Monte Carlo simulations were performed using laser data to model and analyze the contributions of key system components to timing resolution.
  • Performance was compared between bulk scintillator blocks and scintillating fiber blocks of identical dimensions.

Experimental results

Research questions

  • RQ1What timing resolution can be achieved with a long, narrow scintillator block system using standard and fine-mesh photomultipliers?
  • RQ2How does the timing resolution of bulk scintillator blocks compare to that of scintillating fiber blocks of the same dimensions?
  • RQ3What are the dominant factors limiting timing resolution in such a system, as revealed by laser calibration and simulation?
  • RQ4How do photomultiplier characteristics, such as transit time spread and afterpulse effects, influence system performance?
  • RQ5To what extent does internal reflectivity of the scintillator block affect the overall timing resolution?

Key findings

  • The system achieved a timing resolution of 71 ps using Amperex XP2020/UR photomultipliers.
  • A resolution of 81 ps was achieved with the proximity-focusing fine-mesh photomultiplier (Hamamatsu R2021).
  • Bulk scintillator blocks demonstrated superior timing resolution compared to scintillating fiber blocks due to better internal reflectivity.
  • Laser calibration revealed that photomultiplier transit time spread and afterpulse characteristics were critical factors in limiting resolution.
  • Monte Carlo simulations based on laser data successfully reproduced the measured timing resolution and helped isolate key performance-limiting components.
  • The results confirm the feasibility of using long, narrow scintillator blocks with high-performance photomultipliers for high-resolution TOF systems in high-energy physics experiments.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.