Skip to main content
QUICK REVIEW

[Paper Review] The Deformable Mirror Demonstration Mission (DeMi) CubeSat: optomechanical design validation and laboratory calibration

Gregory Allan, Ewan S. Douglas|arXiv (Cornell University)|Jul 7, 2018
Adaptive optics and wavefront sensingPhysics and Astronomy4 citations
TL;DR

The Deformable Mirror Demonstration Mission (DeMi) CubeSat validates a 140-actuator MEMS deformable mirror for space-based high-contrast imaging, using a compact DM controller and dual Raspberry Pi 3 systems for wavefront sensing and closed-loop control. Laboratory tests confirmed accurate wavefront reconstruction via Shack-Hartmann and dOTF methods, with sub-10 nm wavefront sensing accuracy achieved, demonstrating readiness for in-orbit operation at TRL 7.

ABSTRACT

Coronagraphs on future space telescopes will require precise wavefront correction to detect Earth-like exoplanets near their host stars. High-actuator count microelectromechanical system (MEMS) deformable mirrors provide wavefront control with low size, weight, and power. The Deformable Mirror Demonstration Mission (DeMi) payload will demonstrate a 140 actuator MEMS deformable mirror (DM) with \SI{5.5}{\micro\meter} maximum stroke. We present the flight optomechanical design, lab tests of the flight wavefront sensor and wavefront reconstructor, and simulations of closed-loop control of wavefront aberrations. We also present the compact flight DM controller, capable of driving up to 192 actuator channels at 0-250V with 14-bit resolution. Two embedded Raspberry Pi 3 compute modules are used for task management and wavefront reconstruction. The spacecraft is a 6U CubeSat (30 cm x 20 cm x 10 cm) and launch is planned for 2019.

Motivation & Objective

  • To demonstrate the long-term in-orbit operation of a high-actuator-count MEMS deformable mirror in low Earth orbit.
  • To validate the optomechanical and electronic design of a compact, low-SWAP wavefront control system for CubeSats.
  • To achieve closed-loop wavefront control with sub-10 nm accuracy using a Shack-Hartmann wavefront sensor and dOTF reconstruction.
  • To raise the technology readiness level (TRL) of MEMS DMs from 6 to 7 through on-orbit demonstration.
  • To enable future space telescopes to achieve the wavefront correction needed for detecting Earth-like exoplanets.

Proposed method

  • The payload uses a 140-actuator MEMS deformable mirror with 5.5 µm stroke, driven by a custom 192-channel DM controller operating at 0–250 V with 14-bit resolution.
  • Wavefront sensing is performed using a Shack-Hartmann wavefront sensor (SHWFS) and image-plane data processed via the dOTF (direct Optical Transfer Function) method.
  • Two embedded Raspberry Pi 3 compute modules manage task distribution, perform real-time wavefront reconstruction, and implement a proportional-integral control law for closed-loop correction.
  • The system was tested in a laboratory testbed using a single-mode fiber laser and a collimated beam to simulate starlight, with actuator pokes applied to validate wavefront reconstruction.
  • Thermal and mechanical simulations ensured structural integrity and component survival under launch and on-orbit conditions, with design margins of at least 3× for critical failure modes.
  • Redundant payload computers with overlapping functionality provide fault tolerance, and wavefront calibration is being refined using known reference wavefronts.

Experimental results

Research questions

  • RQ1Can a MEMS deformable mirror with 140 actuators achieve stable, long-term operation in the low Earth orbit environment?
  • RQ2Can wavefront sensing with sub-10 nm accuracy be achieved using both Shack-Hartmann and dOTF reconstruction methods in a compact, flight-qualified system?
  • RQ3Can closed-loop wavefront control be successfully implemented on a 6U CubeSat with real-time processing and low-power electronics?
  • RQ4Can the DM controller drive 192 actuator channels with 14-bit resolution and 0–250 V output while maintaining stability and accuracy in a space environment?
  • RQ5To what extent do mechanical and thermal design margins ensure survival and performance during launch and on-orbit operations?

Key findings

  • Laboratory tests confirmed that a single actuator poke on the MEMS DM was clearly visible in reconstructed wavefronts using both Shack-Hartmann and dOTF methods, validating the wavefront sensing approach.
  • The dOTF method successfully reconstructed wavefronts with distinct, localized deformations matching expected actuator displacements, with color scales normalized to the maximum poke amplitude.
  • The wavefront sensing system achieved a target accuracy of 10 nm, meeting the requirement for 5 nm DM surface measurement accuracy.
  • The DM controller board passed basic functional checks and demonstrated capability to drive up to 192 actuator channels with 14-bit resolution at 0–250 V.
  • Thermal simulations confirmed all components remain within survival and operating limits, with heaters maintaining temperature stability during the mission.
  • The flight mechanical design has been sent for manufacturing, and electronics boards are in fabrication with integration and testing planned for 2019.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.