Skip to main content
QUICK REVIEW

[Paper Review] The FASER Detector

FASER Collaboration, H. Abreu|arXiv (Cornell University)|Jul 23, 2022
Particle Detector Development and PerformancePhysics and Astronomy10 citations
TL;DR

This paper presents the design, construction, and commissioning of the FASER detector at CERN's LHC, optimized to search for long-lived, weakly interacting particles in the far-forward region and to detect neutrinos via its FASER𝜈 sub-detector. The detector, installed 480 m downstream of the ATLAS interaction point, features a tracking spectrometer, scintillator systems, a calorimeter, and a magnet system, demonstrating full operational readiness with sub-0.5% dead channels and excellent timing resolution during cosmic-ray and pilot-beam commissioning, enabling physics data-taking in LHC Run 3.

ABSTRACT

FASER, the ForwArd Search ExpeRiment, is an experimentdedicated to searching for light, extremely weakly-interactingparticles at CERN's Large Hadron Collider (LHC). Such particlesmay be produced in the very forward direction of the LHC'shigh-energy collisions and then decay to visible particles insidethe FASER detector, which is placed 480 m downstream of the ATLASinteraction point, aligned with the beam collisions axis. FASER alsoincludes a sub-detector, FASERν, designed to detect neutrinosproduced in the LHC collisions and to study their properties. Inthis paper, each component of the FASER detector is described indetail, as well as the installation of the experiment system and itscommissioning using cosmic-rays collected in September 2021 andduring the LHC pilot beam test carried out in October 2021. FASERhas successfully started taking LHC collision data in 2022, and willrun throughout LHC Run 3.

Motivation & Objective

  • To design and construct a detector system capable of identifying long-lived, weakly interacting particles produced in the far-forward region of LHC proton-proton collisions.
  • To develop a dedicated emulsion-based sub-detector (FASER𝜈) for detecting and studying neutrinos of all flavors produced in LHC collisions.
  • To ensure the detector operates safely and reliably in the challenging environment of the LHC tunnel, including radiation and space constraints.
  • To commission the full detector system using cosmic rays and LHC pilot beams prior to Run 3 data-taking.
  • To validate all subsystems—tracking, calorimetry, timing, trigger, and data acquisition—against performance specifications before physics operations.

Proposed method

  • The FASER detector is positioned 480 m downstream of the ATLAS interaction point in tunnel TI12, aligned with the beam axis, to capture particles produced at very small angles.
  • The detector comprises a tracking spectrometer with three 0.57 T dipole magnets, a decay volume, scintillator veto and timing stations, a pre-shower system, and an electromagnetic calorimeter.
  • The tracking system uses spare ATLAS SCT modules arranged in tracker stations with precise alignment and metrology to reconstruct particle trajectories.
  • The calorimeter and scintillator systems are calibrated using cosmic rays and pilot beam data, with LED-based calibration for gain stability.
  • A trigger system based on signals from scintillators and calorimeters enables real-time event selection, with a DAQ system tested to handle up to 2 kHz with <5% deadtime.
  • Detector control and safety systems, including power, cooling, and interlocks, were implemented to ensure stable and safe long-term operation.

Experimental results

Research questions

  • RQ1Can a compact, forward-directed detector be successfully installed and commissioned in a CERN LHC service tunnel to detect rare, long-lived, weakly interacting particles?
  • RQ2What is the performance of a high-precision tracking spectrometer with magnetic field in a high-radiation, space-constrained environment?
  • RQ3How efficiently can a scintillator-based trigger and data acquisition system operate under high-rate conditions typical of LHC collisions?
  • RQ4Can an emulsion-based detector (FASER𝜈) achieve sufficient spatial resolution and efficiency to detect and study neutrino interactions in the LHC environment?
  • RQ5To what extent does the full detector system, including magnet, tracking, and calorimetry, meet its design specifications during pre-installation and in-situ commissioning?

Key findings

  • The tracker system achieved less than 0.5% non-operational channels, with calibrated gain and noise levels within design specifications.
  • Scintillator counter efficiencies exceeded 99.9% in cosmic-ray and testbeam measurements, meeting the required performance threshold.
  • The timing scintillator system achieved a time resolution of 24–27 ps for the top and bottom layers, demonstrating excellent timing performance.
  • The electromagnetic calorimeter system showed good energy resolution and linearity in cosmic-ray and pilot-beam data, consistent with design expectations.
  • The trigger and data acquisition system operated with less than 5% deadtime at trigger rates up to nearly 2 kHz, exceeding the target of 650 Hz for Run 3.
  • The full detector system successfully operated for months using cosmic rays and during the LHC pilot beam test in October 2021, confirming readiness for Run 3 physics data-taking.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.