Skip to main content
QUICK REVIEW

[Paper Review] The Geant4 mass model of the ATHENA Silicon Pore Optics and its effect on soft proton scattering

V. Fioretti, A. Bulgarelli|arXiv (Cornell University)|Jun 12, 2018
Gamma-ray bursts and supernovaePhysics and Astronomy16 references4 citations
TL;DR

This paper presents a Geant4-based mass model of the ATHENA Silicon Pore Optics (SPO) to simulate soft proton scattering in the L2 environment, using a parameterized, coating-omitted approach for computational efficiency. The model shows that residual soft proton flux on the focal plane is ~10⁴ times lower than the input flux, with weak vignetting and scattering efficiency ~2× higher in the Remizovich model than in single scattering, yet both yield similar angular distributions with ~70% of protons undergoing single or double reflections.

ABSTRACT

Given the unprecedented effective area, the new ATHENA Silicon Pore Optics (SPO) focusing technology, the dynamic and variable L2 environment, where no X-ray mission has flown up to date, a dedicated Geant4 simulation campaign is needed to evaluate the impact of low energy protons scattering on the ATHENA mirror surface and the induced residual background level on its X-ray detectors. The Geant4 mass model is built as part of the ESA AREMBES project activities using the BoGEMMS framework. An SPO mirror module row is the atomic unit of the mass model, allowing the simulation of the full structure by means of 20 independent runs, one for each row. Thanks to the BoGEMMS configuration files, both single pores, mirror modules or the entire SPO row can be built with the same Geant4 geometry. Both Remizovich, in its elastic approximation, and Coulomb single scattering Geant4 models are used in the interaction of mono-energetic proton beams with a single SPO pore. The scattering efficiency for the first model is almost twice the efficiency obtained with the latter but for both cases we obtain similar polar and azimuthal angular distributions, with about 70-75% of scatterings generated by single or double reflections. The soft proton flux modelled for the plasma sheet region is used as input for the simulation of soft proton funnelling by the full SPO mass model. A much weaker soft proton vignetting than the one observed by XMM-Newton EPIC detectors is generated by ATHENA mirrors. The residual soft proton flux reaching the focal plane, defined as a 15 cm radius, is 10^4 times lower than the input L2 soft proton population entering the mirror, at the same energy, with rates comparable or higher than the ones observed in XMM EPIC-pn most intense soft proton flares.

Motivation & Objective

  • To develop a computationally efficient Geant4 mass model of the ATHENA SPO for simulating soft proton interactions in the L2 environment.
  • To evaluate the impact of low-energy protons on the X-ray detectors, particularly residual background levels due to scattering in the Wolter-I optics.
  • To compare the effectiveness of different proton scattering models—Remizovich elastic approximation and Coulomb single scattering—on angular and energy distributions.
  • To quantify the residual soft proton flux reaching the 15 cm focal plane, assessing its potential impact on X-IFU and WFI sensitivity.
  • To validate the model using the BoGEMMS framework and ensure consistency with independent simulations and mission-relevant proton flux inputs.

Proposed method

  • The SPO mass model is built using the BoGEMMS framework, modeling a single row of mirror modules as the atomic unit, enabling 20 independent simulation runs.
  • The model omits reflective coatings on silicon pores, reducing volume count and processing time with only a few percent impact on proton flux predictions.
  • The conical approximation of Si plates reduces photon transmission by ~20% compared to the actual SPO design, with a corresponding 20% uncertainty accepted for proton transmission.
  • Two physics models are used: the Remizovich elastic approximation and Coulomb single scattering, both applied to mono-energetic proton beams in a single pore.
  • The full SPO mass model simulates soft proton funneling using a plasma sheet-based L2 proton flux model as input, with spatial, energy, and angular distributions tracked at the focal plane.
  • Proton scattering efficiency, angular distributions, and residual flux are analyzed for each row and summed, with a 15 cm radius region selected as the focal plane.

Experimental results

Research questions

  • RQ1How does the omission of reflective coatings in the Geant4 SPO mass model affect the simulated soft proton flux and angular distribution?
  • RQ2What is the relative scattering efficiency of the Remizovich elastic model versus the Coulomb single scattering model for protons in a single SPO pore?
  • RQ3How do the polar and azimuthal angular distributions of scattered protons compare between the two physics models?
  • RQ4To what extent does the ATHENA SPO induce vignetting of soft protons, and how does it compare to XMM-Newton's observed vignetting?
  • RQ5What is the residual soft proton flux at the 15 cm focal plane, and how does it compare to the input flux and observed flares in XMM-Newton EPIC-pn?

Key findings

  • The omission of reflective coatings in the SPO mass model reduces simulation processing time with only a few percent change in total proton flux, validating the simplification.
  • The Remizovich elastic model shows approximately twice the scattering efficiency of the Coulomb single scattering model, though both yield similar polar and azimuthal angular distributions.
  • About 70–75% of proton interactions involve single or double reflections in both scattering models, indicating dominant reflection events.
  • The SPO structure induces only weak vignetting, with less than 25% reduction in flux from center to 15 cm radius, in contrast to the ~50% reduction seen in XMM-Newton MOS detectors.
  • The residual soft proton flux at the 15 cm focal plane is ~40 protons cm⁻² s⁻¹ keV⁻¹ at 10 keV, approximately 10⁴ times lower than the input flux at the same energy.
  • At 20 keV, accounting for optical filter stopping power (~20 keV), the residual flux is ~3 protons cm⁻² s⁻¹ keV⁻¹, comparable to or higher than the most intense soft proton flares observed in XMM-Newton EPIC-pn.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.