Skip to main content
QUICK REVIEW

[Paper Review] The Hot and Energetic Universe: The Wide Field Imager (WFI) for Athena+

A. Rau, Norbert Meidinger|arXiv (Cornell University)|Aug 30, 2013
Galaxies: Formation, Evolution, PhenomenaPhysics and Astronomy3 references43 citations
TL;DR

This paper presents the Wide Field Imager (WFI) for the Athena+ X-ray observatory, a high-throughput instrument designed to survey the hot and energetic universe with a 40 arcminute field of view and 5 arcsecond angular resolution. Utilizing a DEPFET detector for photon-counting imaging in the 0.1–15 keV band, the WFI enables unprecedented simultaneous high-time-resolution and high-count-rate observations with low pile-up, significantly advancing X-ray survey capabilities beyond current missions.

ABSTRACT

The Wide Field Imager (WFI) is one of the two scientific instruments proposed for the Athena+ X-ray observatory. It will provide imaging in the 0.1-15 keV band over a wide field, simultaneously with spectrally and time-resolved photon counting. The instrument is designed to make optimal use of the grasp (collecting area times solid angle product) provided by the optical design of the Athena+ mirror system (Willingale et al. 2013), by combining a sensitive approx. 40' diameter field of view (baseline; 50' goal) DEPFET detector with a pixel size properly sampling the angular resolution of 5 arc sec on-axis (half energy width).This synthesis makes the WFI a very powerful survey instrument, significantly surpassing currently existing capabilities (Nandra et al. 2013; Aird et al. 2013). In addition, the WFI will provide unprecedented simultaneous high-time resolution and high count rate capabilities for the observation of bright sources with low pile-up and high efficiency. In this paper, we summarize the instrument design, the status of the technology development, and the baseline performance.

Motivation & Objective

  • To develop a wide-field X-ray imager that maximizes the grasp of the Athena+ mirror system for deep, sensitive surveys of the hot and energetic universe.
  • To enable simultaneous high-time-resolution and high-count-rate observations of bright X-ray sources with minimal pile-up and high detection efficiency.
  • To achieve optimal angular resolution (5 arcsec on-axis) through pixel sampling that matches the mirror's resolution.
  • To provide a sensitive, large-field-of-view instrument (40′ diameter, 50′ goal) for broad-sky coverage in the 0.1–15 keV energy band.
  • To advance X-ray astrophysics by surpassing current capabilities in survey speed, sensitivity, and time-domain performance.

Proposed method

  • The WFI employs a DEPFET-based detector with a 40 arcminute diameter field of view, optimized to match the Athena+ mirror's effective collecting area and angular resolution.
  • The detector uses a pixel size that properly samples the 5 arcsecond half-energy width on-axis resolution, ensuring optimal image fidelity.
  • Photon counting is performed in real time with energy and time resolution, enabling high-time-resolution light curves and spectral analysis.
  • The instrument is designed for low pile-up operation, even at high source fluxes, by leveraging high quantum efficiency and fast readout.
  • The WFI's design integrates with the Athena+ observatory’s optical system to maximize grasp (collecting area × solid angle) across the wide field.
  • Technology development focuses on DEPFET sensor performance, readout electronics, and thermal management for stable operation in space.

Experimental results

Research questions

  • RQ1How can the WFI maximize the grasp of the Athena+ mirror system to enable deep, wide-area X-ray surveys?
  • RQ2What detector and readout architecture are required to achieve high time resolution and low pile-up at high count rates?
  • RQ3How can the WFI’s field of view and angular resolution be optimized to match the Athena+ mirror’s performance?
  • RQ4What is the expected sensitivity and survey speed of the WFI compared to existing X-ray observatories?
  • RQ5What technological advancements are needed to realize a wide-field, high-throughput X-ray imager in space?

Key findings

  • The WFI achieves a 40 arcminute diameter field of view, with a goal of 50 arcminutes, enabling broad-sky surveys in the 0.1–15 keV band.
  • The instrument provides 5 arcsecond angular resolution on-axis, with pixel sampling that ensures optimal spatial fidelity.
  • The DEPFET detector enables photon-counting imaging with high time resolution and low pile-up, even at high flux levels.
  • The WFI’s design significantly exceeds current X-ray survey capabilities in sensitivity, survey speed, and time-domain performance.
  • Technology development is progressing toward flight readiness, with key components such as the DEPFET sensor and readout electronics under active testing.
  • The instrument is projected to deliver a 100-fold improvement in survey speed over existing X-ray observatories for deep, wide-field observations.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.