The NEXT experiment uses a high-pressure xenon time projection chamber with electroluminescent amplification to search for neutrinoless double beta decay in 136Xe, aiming to establish whether neutrinos are Majorana particles. With a projected sensitivity of 6×10²⁵ years (90% CL) after 3 years of operation, NEXT-100 achieves excellent energy resolution and background suppression through tracking, enabling exploration of half-lives beyond 10²⁶ years.
The Neutrino Experiment with a Xenon TPC (NEXT) seeks to discover the neutrinoless double beta ($ββ0ν$) decay of $^{136}$Xe using a high-pressure xenon gas time projection chamber with electroluminescent amplification. The observation of $ββ0ν$ decay would prove that neutrinos are Majorana particles and that lepton number is not conserved. The NEXT detector concept offers several features of great value for $ββ0ν$-decay searches, including excellent energy resolution, tracking for the active suppression of backgrounds and scalability to large source masses. The initial phase of the NEXT project (2009-2014) was devoted to R&D with two prototypes (DEMO and DBDM) of approximately 1 kg of active xenon mass that demonstrated the performance of the detector concept. During the second phase of the project (2015-2019), the NEXT Collaboration has operated underground at the Laboratorio Subterráneo de Canfranc, in Spain, a radio-pure detector of about 5 kg of xenon mass. The goal of the current phase is the construction, commissioning and operation of the NEXT-100 detector, with a predicted sensitivity to the $β\beta0ν$ decay half-life of $6 imes10^{25}$ years (90% CL) after a run of 3 years. The Collaboration is planning as well a future tonne-scale phase to explore $ββ0ν$-decay half-lives beyond $10^{26}$ years.
Motivation & Objective
- To search for neutrinoless double beta decay in 136Xe, a process that would prove neutrinos are Majorana particles and lepton number is not conserved.
- To achieve a sensitivity to 0νββ decay half-life of 6×10²⁵ years (90% CL) after 3 years of data-taking with the NEXT-100 detector.
- To develop and demonstrate scalable, low-background detector technology suitable for tonne-scale experiments.
- To explore future phases including NEXT-HD (high-definition) and NEXT-BOLD (barium tagging via single-molecule fluorescence imaging) for enhanced sensitivity beyond 10²⁸ years.
Proposed method
- The NEXT detector employs a high-pressure xenon gas time projection chamber (HPXe-TPC) operating at 15 bar with 100 kg of 136Xe-enriched xenon.
- Ionization and excitation from charged particles produce prompt scintillation light (175 nm) and drift electrons, which are amplified via electroluminescence in a high-field region near the anode.
- Photosensors (PMTs and SiPMs) detect primary scintillation for event timing and electroluminescent light for calorimetry and track reconstruction.
- Background suppression is achieved through charged-particle tracking, enabling discrimination between two-electron events (signal) and single-electron events (background).
- The detector uses a radio-pure design with copper and lead shielding, and a stainless steel pressure vessel rated for 20 bar.
- Future phases include replacing PMTs with SiPMs for lower background, optimizing with low-diffusion gas mixtures, and developing barium tagging via single-molecule fluorescence imaging (SMFI).
Experimental results
Research questions
- RQ1Can a high-pressure xenon time projection chamber with electroluminescent amplification achieve the necessary energy resolution and background suppression for a sensitive 0νββ decay search?
- RQ2What is the achievable sensitivity of the NEXT-100 detector to the 0νββ decay half-life of 136Xe, and how does it compare to current limits?
- RQ3Can the NEXT detector technology be scaled to tonne-scale masses while maintaining a low background index?
- RQ4Can single-molecule fluorescence imaging of Ba++ ions enable background-free detection of 0νββ decay events?
- RQ5What are the key technological advancements required to achieve sensitivities beyond 10²⁸ years?
Key findings
- The NEXT-100 detector achieves a projected sensitivity of 6×10²⁵ years (90% CL) for the 0νββ decay half-life of 136Xe after 3 years of operation.
- Energy resolution at 2.5 MeV is better than 1% FWHM, as demonstrated by the NEXT-White prototype.
- The NEXT-White detector demonstrated robust discrimination between two-electron tracks (signal) and single electrons (main background) using tracking information.
- The radiogenic background budget was measured and found to be consistent with low-background expectations, validating the background model.
- The NEXT-100 detector is expected to have a background index of at most 4×10⁻⁴ counts keV⁻¹ kg⁻¹ yr⁻¹, enabling high sensitivity.
- Monte Carlo simulations suggest that the NEXT-HD phase could reduce the specific background rate by at least one order of magnitude, improving sensitivity beyond 10²⁸ years.