Skip to main content
QUICK REVIEW

[Paper Review] The Pointing System of the Herschel Space Observatory. Description, Calibration, Performance and Improvements

Miguel Sánchez-Portal, A. P. Marston|arXiv (Cornell University)|May 13, 2014
Stellar, planetary, and galactic studiesPhysics and Astronomy3 references23 citations
TL;DR

This paper details the calibration, performance characterization, and ongoing improvements of the Herschel Space Observatory's pointing system, achieving sub-arcsecond absolute pointing accuracy (≤1 arcsec) and high stability (<0.2 arcsec) through ground-based corrections and multi-instrument alignment. It presents a comprehensive framework for attitude determination using star trackers, gyroscopes, and on-ground processing, emphasizing cross-team collaboration to refine astrometric accuracy throughout the mission.

ABSTRACT

We present the activities carried out to calibrate and characterise the performance of the elements of attitude control and measurement on board the Herschel spacecraft. The main calibration parameters and the evolution of the indicators of the pointing performance are described, from the initial values derived from the observations carried out in the performance verification phase to those attained in the last year and half of mission, an absolute pointing error around or even below 1 arcsec, a spatial relative pointing error of some 1 arcsec and a pointing stability below 0.2 arsec. The actions carried out at the ground segment to improve the spacecraft pointing measurements are outlined. On-going and future developments towards a final refinement of the Herschel astrometry are also summarised. A brief description of the different components of the attitude control and measurement system (both in the space and in the ground segments) is also given for reference. We stress the importance of the cooperation between the different actors (scientists, flight dynamics and systems engineers, attitude control and measurement hardware designers, star-tracker manufacturers, etc.) to attain the final level of performance.

Motivation & Objective

  • To calibrate and characterize the performance of the Herschel spacecraft's attitude control and measurement system components.
  • To reduce absolute and relative pointing errors to sub-arcsecond levels for high-precision astronomical observations.
  • To improve on-ground pointing accuracy through advanced processing algorithms and data correction techniques.
  • To ensure consistent alignment of instrument fields of view with the telescope's boresight across all observing modes.
  • To support long-duration science operations by maintaining pointing stability and reliability over the mission lifetime.

Proposed method

  • Utilized on-board star trackers (STR) and gyroscopes (GYR) for real-time attitude determination and control.
  • Applied ground-based filtering and correction algorithms to refine the on-board attitude quaternion data, reducing errors from raw telemetry.
  • Implemented a multi-step attitude processing chain: on-board filtered quaternion → gyro-propagated quaternion → ground-processed corrected quaternion.
  • Used quality indices (STR quality, gyro quality) and flags (e.g., isSlew, isOnTarget) to assess attitude solution reliability.
  • Employed the Attitude Control and Measurement System (ACMS) to combine STR and GYR data into a stable, high-accuracy attitude solution.
  • Conducted performance verification during early mission phases and continuously monitored pointing evolution through mission operations.

Experimental results

Research questions

  • RQ1What is the initial pointing accuracy of the Herschel spacecraft, and how does it evolve over time?
  • RQ2How effective are ground-based correction algorithms in reducing absolute and relative pointing errors?
  • RQ3What role do star tracker quality indices and gyro-propagation play in maintaining pointing stability?
  • RQ4How was the alignment of instrument fields of view with the telescope boresight calibrated and maintained?
  • RQ5What improvements were achieved in astrometric accuracy through on-ground processing and system refinements?

Key findings

  • The absolute pointing error was reduced to approximately 1 arcsec or less by the final year and a half of the mission.
  • The spatial relative pointing error remained at around 1 arcsec, ensuring consistent instrument alignment.
  • Pointing stability was maintained below 0.2 arcsec, critical for high-resolution mapping and spectroscopy.
  • Ground-processed pointing solutions improved accuracy significantly, with the best results achieved using refined algorithms in SPG versions >v11.1.0.
  • The pointing quality index derived from star tracker data served as a reliable error metric, with values below 1.4 arcsec indicating high-quality attitude solutions.
  • The final astrometric accuracy was enhanced through ongoing calibration and processing, with extreme outliers (≥8 arcsec) reduced to negligible levels in later mission phases.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.