TL;DR

This paper presents the design, fabrication, and performance evaluation of a cryogenic continuously rotating half-wave plate (CHWP) for the Simons Observatory's small aperture telescopes (SATs). The CHWP, operating at 50 K with a superconducting magnetic bearing and electromagnetic motor, rotates at 2 Hz to modulate cosmic microwave background (CMB) polarization at 8 Hz, suppressing atmospheric 1/f noise and reducing systematic errors. Key results include sub-microradian angular resolution (0.07 μrad√s), 0.02° encoder accuracy, and ±0.3 mm displacement control, enabling high-precision B-mode polarization measurements.

ABSTRACT

We present the requirements, design and evaluation of the cryogenic continuously rotating half-wave plate (CHWP) for the Simons Observatory (SO). SO is a cosmic microwave background (CMB) polarization experiment at Parque Astronómico Atacama in northern Chile that covers a wide range of angular scales using both small (0.42 m) and large (6 m) aperture telescopes. In particular, the small aperture telescopes (SATs) focus on large angular scales for primordial B-mode polarization. To this end, the SATs employ a CHWP to modulate the polarization of the incident light at 8 Hz, suppressing atmospheric $1/f$ noise and mitigating systematic uncertainties that would otherwise arise due to the differential response of detectors sensitive to orthogonal polarizations. The CHWP consists of a 505 mm diameter achromatic sapphire HWP and a cryogenic rotation mechanism, both of which are cooled down to $\sim$50 K to reduce detector thermal loading. Under normal operation the HWP is suspended by a superconducting magnetic bearing and rotates with a constant 2 Hz frequency, controlled by an electromagnetic synchronous motor. We find that the number of superconductors and magnets that make up the superconducting magnetic bearing are important design parameters, especially for the rotation mechanism's vibration performance. The rotation angle is detected through an angular encoder with a noise level of 0.07 $μ$rad$\sqrt{\mathrm{s}}$. During a cooldown, the rotor is held in place by a grip-and-release mechanism that serves as both an alignment device and a thermal path. In this paper we provide an overview of the SO SAT CHWP: its requirements, hardware design, and laboratory performance.

Motivation & Objective

  • To enable high-precision measurement of primordial B-mode polarization in the cosmic microwave background (CMB) by suppressing atmospheric 1/f noise and detector systematics.
  • To develop a cryogenic, continuously rotating half-wave plate (CHWP) that operates reliably at 50 K in the harsh environment of the Simons Observatory's small aperture telescopes (SATs).
  • To achieve stable, high-accuracy rotation control with minimal vibration and precise angular encoding for polarization modulation at 8 Hz.
  • To ensure mechanical stability and thermal isolation through a superconducting magnetic bearing and a grip-and-release mechanism for rotor alignment and thermal management.

Proposed method

  • The CHWP uses a 505 mm diameter achromatic sapphire half-wave plate mounted on a rotor suspended by a superconducting magnetic bearing.
  • Rotation is driven by an electromagnetic synchronous motor operating at 2 Hz, synchronized via an IRIG-B reference signal.
  • Angular position is measured using dual optical encoders with 1140 slots, providing 0.07 μrad√s noise level and enabling off-center displacement detection via time delay between diametrically opposed slots.
  • A grip-and-release mechanism holds the rotor during cooldown, with displacement monitored via Hall probes and mechanical play accounted for in calibration.
  • Thermal isolation is maintained by cooling the system to ~50 K, minimizing thermal loading on detectors.
  • Vibration and mechanical interference are minimized through careful component selection, use of non-magnetic materials, and secure fastening with thread-locker and epoxy.

Experimental results

Research questions

  • RQ1How can a cryogenic, continuously rotating half-wave plate achieve stable, low-noise rotation at 50 K for CMB polarization measurements?
  • RQ2What mechanical and thermal design strategies ensure reliable operation and minimal thermal loading in a cryogenic environment?
  • RQ3How accurately can the rotor's angular position and displacement be measured to enable precise polarization modulation?
  • RQ4What methods are effective for aligning and releasing the rotor during cooldown without causing mechanical interference?
  • RQ5How do system-level precautions such as electrical protection and material selection prevent operational failure?

Key findings

  • The angular encoder achieves a noise level of 0.07 μrad√s, enabling high-precision angular position measurement.
  • The rotor's axial displacement is measured with a systematic error of ±0.3 mm, primarily due to Hall probe sensitivity drift and magnet field changes.
  • Off-center displacement perpendicular to the encoder line is measured with 0.02° accuracy, corresponding to a displacement resolution of ~0.06 mm at 334 mm radius.
  • The CHWP achieves stable rotation at 2 Hz with minimal vibration, confirmed by performance testing and operational stability.
  • The grip-and-release mechanism successfully holds the rotor during cooldown and allows controlled release without mechanical interference.
  • The system maintains thermal isolation and operational stability, with no observed physical interference during testing, thanks to non-magnetic materials and secure fastening.

Read this paper