[Paper Review] The Simons Observatory: On-sky performance of radio-transparent multi-layer insulation (RT-MLI) using Styroace-II Styrofoam
This paper reports on-field performance of a Styroace-II RT-MLI filter stack for the SO SATs, showing >90% IR rejection and <12 W transmitted power, with in-band transmission consistent with at least 95%.
We present the on-sky performance of a Radio-Transparent Multi-Layer Insulation filter (RT-MLI) that uses Styroace-II styrofoam to reject ambient thermal radiation from entering a 0.42 m diameter aperture to a sub-100 mK bolometric detector array cooled by a dilution-refrigerator. We find that greater than 90% of the expected incident infra-red (IR) radiation is rejected, resulting in $<$12 W of measured transmitted power. Transmitted power in the detector passbands is consistent with a lower bound of 95%. We address filter design and placement, thermal loading, and mm-wave transmission.
Motivation & Objective
- Assess the infrared (IR) rejection performance of a radio-transparent multi-layer insulation (RT-MLI) stack using Styroace-II Styrofoam.
- Quantify the transmitted power to cryogenic stages under field conditions and compare to design expectations.
- Evaluate in-band transmission in the 90/150 GHz bands via astronomical beam measurements and simulations.
- Characterize the filter design, placement, and thermal loading impacts on the SAT cryogenic system.
Proposed method
- Implement a 24-layer Styroace-II RT-MLI stack (46 mm total thickness) in a 664 mm ID holder at 40 K above the CHWP assembly.
- Model expected radiative loading using a layered MLI framework and compare to measured 40 K stage loads.
- Measure IR rejection on-field via temperatures of 40 K and 4 K stages and CHWP cavity to bound transmitted power.
- Estimate in-band transmission end-to-end using Jupiter beam measurements and compare to detector simulations with a baseline 0.96 RT-MLI transmission.
- Use lab load curves and ambient temperature scaling to separate window-related loading from CHWP-induced heating.
- Reference end-to-end detector efficiency and atmospheric transmission to interpret in-field transmission results.
Experimental results
Research questions
- RQ1What is the on-sky IR rejection performance of the Styroace-II RT-MLI stack for SO SATs?
- RQ2How much radiative power is transmitted to 40 K and colder stages through the RT-MLI and window, and how does this compare to design expectations?
- RQ3What is the in-band (90/150 GHz) transmission efficiency of the RT-MLI stack within the full optical path?
- RQ4How does the RT-MLI performance compare to the previous metal mesh IR filter configuration under field conditions?
Key findings
- The RT-MLI stack rejects more than 90% of the expected incident IR radiation from the cryostat window.
- Measured transmitted power to the 40 K stage is below 12 W (upper bound), with an estimated field loading of 8 ± 2 W after ambient correction.
- The in-field end-to-end efficiency using Jupiter beam measurements is consistent with a 95% lower bound on in-band transmission through the RT-MLI stack.
- Independent in-lab transmission measurements of the exact Styroace-II configuration show better than 95% transmission below 200 GHz.
- The RT-MLI configuration results in lower 40 K temperatures and more stable CHWP operation compared to the metal mesh stack, with diurnal ambient fluctuations having minimal impact on colder stages.
- The Styroace-II RT-MLI stack is cost-effective (~$1000) and straightforward to implement, though higher-frequency performance (>150 GHz) requires further comparison to other foams.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.