[Paper Review] The superconducting proposal for the CS magnet system of FAST: a preliminary analysis of the heat load due to AC losses
This paper evaluates AC losses in a superconducting central solenoid (CS) for the FAST tokamak under a high-field, high-ramp-rate H-mode scenario, finding that AC losses—especially coupling losses—lead to substantial heat loads (up to 140 kW in 0.04 s), necessitating advanced cable designs with reduced effective strand diameter and improved thermal performance to meet cooling requirements.
FAST (Fusion Advanced Studies Torus), the Italian proposal of a Satellite Facility to ITER, is a compact tokamak (R$_0$ = 1.82 m, a = 0.64 m, triangularity $δ$ = 0.4) able to investigate non-linear dynamics effects of $α$-particle behavior in burning plasmas and to test technical solutions for the first wall/divertor directly relevant for ITER and DEMO. Currently, ENEA is investigating the feasibility of a superconducting solution for the magnet system. This paper focuses on the analysis of the CS (Central Solenoid) magnet thermal behavior. In particular, considering a superconducting solution for the CS which uses the room available in the resistive design and referring to one of the most severe scenario envisaged for FAST, the heat load of the CS winding pack due to AC losses is preliminarily evaluated. The results provide a tentative baseline for the definition of the strand requirements and conductor design, that can be accepted in order to fulfil the design requirements.
Motivation & Objective
- To assess the feasibility of a superconducting solution for the FAST central solenoid (CS) under stringent operational conditions.
- To evaluate the AC loss-induced heat load on the CS winding pack during the H-mode reference scenario, a high-field, high-ramp-rate operational phase.
- To provide a baseline for strand and conductor design requirements to meet thermal stability and cooling constraints.
- To identify critical thermal margins and guide future thermohydraulic design optimization.
- To determine whether the resistive design's volume constraints are compatible with a viable superconducting CS solution.
Proposed method
- Performed a 3D electromagnetic analysis using Opera-3D to compute time- and position-dependent magnetic fields (Bz, Br, Bφ) across the CS1U/CS1L modules.
- Modelled the pancake winding pack as subjected to a unidirectional transverse field (Bz), assuming uniform field at median radius of each turn.
- Applied a dynamic model for AC losses in Nb3Sn cables, including both coupling and hysteresis losses, with a focus on the pre-saturated and saturated regimes.
- Used a modified power loss model incorporating effective strand diameter (deff), normal state resistivity (ρ), and time constants (nτ) to estimate dissipation.
- Calculated total dissipated energy and temperature rise by comparing AC loss power to helium cooling capacity (4.7 kJ/K in nominal conditions).
- Evaluated sensitivity of losses to key parameters: deff (10 μm), nτ (10 ms), and D_eff, using comparative scenarios to assess design improvements.
Experimental results
Research questions
- RQ1What is the magnitude of AC losses in a superconducting CS for FAST under the most severe H-mode reference scenario?
- RQ2How do coupling losses compare to hysteresis losses during rapid field ramp-up and ramp-down phases?
- RQ3What are the thermal implications of the peak AC loss power (especially during the 0.04 s ramp-down) on the CS winding pack?
- RQ4To what extent can cable design improvements (e.g., reduced deff, lower nτ) reduce AC losses and improve thermal stability?
- RQ5Can the existing resistive design’s volume constraints accommodate a viable superconducting CS solution without excessive thermal margins?
Key findings
- The AC loss heat load in the CS winding pack reaches a peak of 140 kW during the initial 0.04 s ramp-down phase, primarily due to coupling losses.
- The average AC loss power during the flat top phase is approximately 194 W, with cooling capacity estimated at 19 W/K, indicating a tight thermal margin.
- In the initial ramp-down, the total dissipated energy is 5.6 kJ, leading to a predicted temperature rise of ~1 K if no design improvements are made.
- Reducing effective strand diameter (deff) to 10 μm and time constant (nτ) to 10 ms reduces the dissipated energy in the initial phase to 1 kJ, corresponding to a more sustainable ~0.2 K temperature rise.
- The model shows that coupling losses dominate, especially near the 7th turn, where a sharp peak occurs due to the transition from saturated to non-saturated regime.
- Without improved cable models and accurate D_eff estimation, current approximations overestimate losses, especially in the non-saturated regime, limiting design confidence.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.